Diagnostic Procedure with Diagnostic Trouble Code (DTC)
ENGINE (DIAGNOSTIC)
Step
1
CHECK OUTPUT SIGNAL FROM ECM.
1) Turn the ignition switch to ON.
2) Measure the voltage between ECM and
chassis ground.
Connector & terminal
(B134) No. 14 (+) — Chassis ground (
2
CHECK HARNESS BETWEEN PURGE CON-
TROL SOLENOID VALVE AND ECM CON-
NECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connectors from purge con-
trol solenoid valve and ECM.
3) Measure the resistance of harness
between purge control solenoid valve connec-
tor and engine ground.
Connector & terminal
(E4) No. 2 — Engine ground:
3
CHECK HARNESS BETWEEN PURGE CON-
TROL SOLENOID VALVE AND ECM CON-
NECTOR.
Measure the resistance of harness between
ECM and purge control solenoid valve of har-
ness connector.
Connector & terminal
(B134) No. 14 — (E4) No. 2:
4
CHECK PURGE CONTROL SOLENOID
VALVE.
1) Remove the purge control solenoid valve.
2) Measure the resistance between purge
control solenoid valve terminals.
Terminals
No. 1 — No. 2:
5
CHECK POWER SUPPLY TO PURGE CON-
TROL SOLENOID VALVE.
1) Turn the ignition switch to ON.
2) Measure the voltage between purge control
solenoid valve and engine ground.
Connector & terminal
(E4) No. 1 (+) — Engine ground (
6
CHECK POOR CONTACT.
Check poor contact in purge control solenoid
valve connector.
Check
Is the voltage more than 10 V? Even if the mal-
):
Is the resistance more than 1
MΩ?
Is the resistance less than 1
Ω?
Is the resistance 10 — 100 Ω? Go to step 5.
Is the voltage more than 10 V? Go to step 6.
):
Is there poor contact in purge
control solenoid valve connec-
tor?
EN(H4DOTC 2.5)-142
Yes
Go to step 2.
function indicator
light illuminates,
the circuit has
returned to a nor-
mal condition at
this time.
Go to step 3.
Repair ground
short circuit in har-
ness between
ECM and purge
control solenoid
valve connector.
Go to step 4.
Repair open circuit
in harness between
ECM and purge
control solenoid
valve connector.
NOTE:
In this case repair
the following:
• Open circuit in
harness between
ECM and purge
control solenoid
valve connector
• Poor contact in
coupling connector
Replace the purge
control solenoid
valve. <Ref. to
EC(H4DOTC)-7,
Purge Control
Solenoid Valve.>
Repair open circuit
in harness
between main
relay and purge
control solenoid
valve connector.
Repair poor con-
Contact the SUB-
tact in purge con-
ARU dealer.
trol solenoid valve
NOTE: