Subaru Forester 2004 Service Manual page 129

Engine section 3
Hide thumbs Also See for Forester 2004:
Table of Contents

Advertisement

Diagnostic Procedure with Diagnostic Trouble Code (DTC)
ENGINE (DIAGNOSTIC)
Step
1
CHECK OUTPUT SIGNAL FROM ECM.
1) Turn the ignition switch to ON.
2) Measure the voltage between ECM and
chassis ground.
Connector & terminal
(B134) No. 32 (+) — Chassis ground (
2
CHECK HARNESS BETWEEN WASTEGATE
CONTROL SOLENOID VALVE AND ECM
CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connectors from wastegate
control solenoid valve and ECM.
3) Measure the resistance in harness
between wastegate control solenoid valve con-
nector and engine ground.
Connector & terminal
(B127) No. 1 — Engine ground:
3
CHECK HARNESS BETWEEN WASTEGATE
CONTROL SOLENOID VALVE AND ECM
CONNECTOR.
Measure the resistance of harness between
wastegate control solenoid valve and ECM.
Connector & terminal
(B134) No. 32 — (B127) No. 1:
4
CHECK WASTEGATE CONTROL SOLE-
NOID VALVE.
1) Remove the wastegate control solenoid
valve.
2) Measure the resistance between wastegate
control solenoid valve terminals.
Terminals
No. 1 — No. 2:
5
CHECK POWER SUPPLY TO WASTEGATE
CONTROL SOLENOID VALVE.
1) Turn the ignition switch to ON.
2) Measure the voltage between wastegate
control solenoid valve and engine ground.
Connector & terminal
(B127) No. 2 (+) — Engine ground (
6
CHECK POOR CONTACT.
Check poor contact in wastegate control sole-
noid valve connector.
Check
Is the voltage more than 10 V? Even if the mal-
):
Is the resistance less than 10
Ω?
Is the resistance less than 1
Ω?
Is the resistance 30 — 34 Ω?
Is the voltage more than 10 V? Go to step 6.
):
Is there poor contact in waste-
gate control solenoid valve
connector?
EN(H4DOTC 2.5)-128
Yes
Go to step 2.
function indicator
light illuminates,
the circuit has
returned to a nor-
mal condition at
this time.
Repair ground
Go to step 3.
short circuit in har-
ness between
ECM and waste-
gate control sole-
noid valve
connector.
Go to step 4.
Repair open circuit
in harness
between ECM and
wastegate control
solenoid valve
connector.
NOTE:
In this case repair
the following:
• Open circuit in
harness between
ECM and waste-
gate control sole-
noid valve
connector
Go to step 5.
Replace the
wastegate control
solenoid valve.
<Ref. to
FU(H4DOTC 2.5)-
35, Wastegate
Control Solenoid
Valve.>
Repair open circuit
in harness
between main
relay and waste-
gate control sole-
noid valve
connector.
Repair poor con-
Contact the SUB-
tact in wastegate
ARU dealer.
control solenoid
NOTE:
valve connector.
Inspection by DTM
is required, because
probable cause is
deterioration of mul-
tiple parts.
No

Advertisement

Table of Contents
loading

Table of Contents