IBM x Series 200 Hardware Maintenance Manual page 106

Ibm computer drive hardware maintenance manual
Table of Contents

Advertisement

Error Code/Symptom
00019501
(Microprocessor is not
functioning - check VRM and
processor LEDs)
00019701
(Microprocessor failed BIST)
00180100
(No room for PCI option
ROM)
00180200
(No more I/O space available
for PCI adapter)
00180300
(No more memory (above
1MB for PCI adapter))
00180400
(No more memory (below
1MB for PCI adapter))
00180500
(PCI option ROM checksum
error)
00180600
(PCI device built-in self test
failure)
00180700
(xxxxyyyy planar PCI device
not responding (where xxxx
is PCI vendor ID and yyyy is
PCI device ID))
00180800
(Unsupported PCI device
installed)
00181000
(PCI error)
01295085
(ECC checking hardware test
error)
01298001
(No update data for
microprocessor)
98
Hardware Maintenance Manual: xSeries 200
1.
Microprocessor
2.
System Board
1.
Microprocessor
2.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
Remove Failing PCI Card
2.
System Board
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1.
System Board
2.
PCI Card
1.
System Board
2.
PCI Card
1.
System Board
2.
PCI Card
1.
System Board
2.
Microprocessor
1.
Ensure all microprocessors are the same stepping level and cache size.
2.
Microprocessor
FRU/Action

Advertisement

Table of Contents
loading

Table of Contents