Dimensional Drawing - Bryant 355BAV Installation, Start-Up, And Operating Instructions Manual

Direct-vent upflow variable-capacity condensing gas furnace
Hide thumbs Also See for 355BAV:
Table of Contents

Advertisement

26
15
"
(684 mm)
16
26
1
(667 mm)
"
4
24
1
"
(622 mm)
2
22
5
(567 mm)
"
16
2-IN . (51 mm) COMBUSTION-
AIR CONN
1
-IN . (13mm) DI A
2
GAS CONN
.
2-IN (51mm)
VENT CONN
1
-IN . DIA (13mm)
2
THERMOST A T ENT RY
22
11
"
16
(576 mm)
14
1
SIDE INLE T
"
2
TYP
(368 mm)
1
1
"
(32 mm)
(591 mm)
4
1 "
23
1
" TYP
4
SIDE INLE T
(25mm)
26
15
" TYP
16
(684 mm)
UNIT SIZE
060---14 / 042060
080---14 / 042080
080---20 / 060080
100---20 / 060100
120---20 / 060120
A gas- -fired furnace for installation in a residential garage must be
installed as specified in the Hazardous Locations section of these
instructions and Fig. 5.
The furnace may be used for construction heat provided that the
furnace installation and operation complies with the first
CAUTION in the LOCATION section of these instructions.
This gas furnace may be used for construction heat provided that:
S The furnace is permanently installed with all electrical wiring,
piping, air filters, venting and ducting installed according to
these installation instructions. A return air duct is provided,
sealed to the furnace casing, and terminated outside the space
containing the furnace. This prevents a negative pressure
condition as created by the circulating air blower, causing a
flame rollout and/or drawing combustion products into the
structure.
S The furnace is controlled by a thermostat. It may not be "hot
wired" to provide heat continuously to the structure without
thermostatic control.
S Clean outside air is provided for combustion. This is to
minimize the corrosive effects of adhesives, sealers and other
construction materials. It also prevents the entrainment of
CONDENSA TE DRAI N
(21 mm)
TRAP LOCA TION
(DO WNFLO W &
HORIZONT AL LEFT )
7
-IN . DI A (22mm)
8
PO WER CONN
33
30
13
"
16
TYP
(783 mm)
(845 mm)
29
11
"
16
7
TYP
-IN . DI A (22mm)
8
A CCESSOR Y
32
5
(754 mm)
"
8
PO WER ENT RY
TYP
27
5
"
8
(829 mm)
(702 mm)
CONDENSA TE
DRAIN TRAP
27
9
"
16
LOCA TION
TYP
(700 mm)
(AL TERNA TE
UPFL OW )
24
1
"
2
(622 mm)
9
7
"
17
5
"
16
16
TYP
(439 mm)
(240 mm)
CONDENSA TE
DRAIN LOCA TIO N
(17 mm)
(UPFLO W)
NO TES: 1. Minimum retur n-air openings at fur nace , based on metal duct. If fle x duct is used,
see fle x duct manuf acturerí s recommendations f or equiv alent diameters .
2. Minimum retur n-air opening at fur nace:
a. F or 800 CFM–16-in. (406mm) round or 14
b. F or 1200 CFM–20-in. (508mm) round or 14
c. F or 1600 CFM–22-in. (559mm) round or 14
d. F or airflo w requirements abo v e 1800 CFM, see Air Deliv er y tab le in Product Data
literature f or specific use of single side inlets . The use of both side inlets , a
combination of 1 side and the bottom, or the bottom only will ensure adequate
retur n air openings f or airflo w requirements abo v e 1800 CFM .
Dimensions - - In. (mm)
A
17--- 1/2 / 445
21 / 533
21 / 533
21 / 533
24--- 1/2 / 622
Fig. 2 - - Dimensional Drawing
AIRFL OW
A
13
/
D
13
/
"
"
16
16
(21 mm)
OUTLET
CONDENSA TE DRAI N
TRAP LOCA TION
(DO WNFL OW &
HORIZONT AL RIGHT)
OR AL TERNA TE
1
-IN . DIA GAS CONN
2
1
"
4
30
(775 mm)
INLE T
CONDENSA TE
DRAIN LOCA TION
11
/
"
E
11
/
"
16
16
(17 mm)
DIMPLE LOCA T ORS
FOR HORIZONT AL
/
(368 mm)x 12-in. (305 mm) rectangle
.
1
2
/
(368mm)x 19
/
-in. (495mm) rectangle
1
1
2
2
/
(368mm)x 23
/
-in. (591mm) rectangle
1
1
2
4
D
15--- 7/8 / 403
19--- 3/8 / 492
19--- 3/8 / 492
19--- 3/8 / 492
22--- 7/8 / 581
drywall dust into combustion air, which can cause fouling and
plugging of furnace components.
S The temperature of the return air to the furnace is maintained
between 55_F (13_C) and 80_F (27_C), with no evening
setback or shutdown. The use of the furnace while the structure
is under construction is deemed to be intermittent operation per
our installation instructions.
S The air temperature rise is within the rated rise range on the
furnace rating plate, and the firing rate has been set to the
nameplate value.
S The filters used to clean the circulating air during the
construction process must be either changed or thoroughly
cleaned prior to occupancy.
S The furnace, ductwork and filters are cleaned as necessary to
remove drywall dust and construction debris from all HVAC
system components after construction is completed.
S After construction is complete, verify furnace operating
conditions including ignition, input rate, temperature rise and
venting, according to the manufacturer's instructions.
5
(724 mm)
28
1
"
2
26
15
"
(684 mm)
16
1
(667 mm)
26
"
4
(14 mm)
(567 mm)
22
5
"
16
9
"
(483 mm)
16
19 "
TYP
OUTLET
2-IN . (51mm)
COMBUSTION-AIR CONN
1
-IN . DI A (13mm)
2
GAS CONN
7
-IN . DI A (22mm)
8
PO WER CONN
1
-IN . DI A (13 mm)
2
THERMOS T A T ENTR Y
1
"
2
2-IN . (51 mm)
VENT CONN
22
11
"
16
(576 mm)
SIDE INLE T
18
1
"
4
(464 mm)
22
1
" TYP
4
(565 mm)
(UPFL OW )
24
3
"
16
BO TT OM INLE T
(614 mm)
HANGING
.
.
E
16 / 406
19--- 1/2 / 495
19--- 1/2 / 495
19--- 1/2 / 495
23 / 584
13
"
(21 mm)
16
(16 mm)
5
"
8
5
"
16
(16 mm)
39
7
"
8
(1013 mm)
(25 mm)
1 "
(11 mm)
7
"
16
11
(25 mm)
"
16
A05124