Bryant 355BAV Installation, Start-Up, And Operating Instructions Manual page 36

Direct-vent upflow variable-capacity condensing gas furnace
Hide thumbs Also See for 355BAV:
Table of Contents

Advertisement

AIR CONDITIONING
TONS (12,000 BTU/HR)
1-1/2
2
2-1/2
3
3-1/2
4
5
6
X-INDICATES AN ALLOWABLE SELECTION.
* Airflow shown in parentheses is airflow unit that the unit will deliver when setup switch SW1-5 is ON (selects 400 CFM/ton)
MODEL
080-14
080-20, 100
1.DEFAULT A/C AIRFLOW WHEN A/C SWITCHES ARE IN OFF POSITION
2.DEFAULT CONT. FAN AIRFLOW WHEN CF SWITCHES ARE IN OFF POSITION
Fig. 39 - - A/C or CF Airflow Selection Chart Based on 350 and 400CFM/Ton
SETUP SWITCH
SWITCH NAME
NO.
SW1---1
Status Code Recovery
SW1---2
Adaptive Heat Mode
SW1---3
Low Heat Rise Adjust
SW1---4
Comfort/Efficiency Adjustment
SW1---5
CFM per ton adjust
SW1---6
Component Self--- Test
SW1---7
Blower OFF delay
SW1---8
Blower OFF delay
AIRFLOW*
060 & 080-14
(CFM)
525 (600)
700 (800)
875 (1000)
1050 (1200)
1225 (1400)
1400 (1600)
1750 (2000)
2100 (2100)
A/C OR CF AIRFLOW SELECTION CHART
BASED ON 350 CFM/TON
SIZE
060,
DEF
525
2
DEF
700
875
2
120
DEF
700
875
Table 9 – Furnace Setup Switch Description
NORMAL
POSITION
OFF
OFF
OFF
ON
OFF
OFF
ON or OFF
ON or OFF
080-20 & 100
MODEL
MODEL
X
X
X
X
X
700
875
1050
1225
1
1050
1225
1400
1050
1225
1400
2
Turn ON to retrieve up to 7 stored status codes for troubleshooting
assistance when R thermostat lead is disconnected.
Allows 2--- stage operation with a single stage thermostat. Turn ON
when using 2 stage thermostat to allow Low Heat operation when
R to W/W1 closes and High Heat operation when R to W/W1 and
Turn ON to increase Low Heat airflow by 10 percent. This com-
pensates for increased return air temperature caused with bypass
Turn ON to decrease Low Heat airflow by 22 percent and High
Heat airflow 15 percent for maximum comfort.
Turn ON for 400 CFM per ton. Turn OFF for 350 CFM per ton.
Turn ON to initiate Component Self--- Test for troubleshooting as-
sistance when R thermostat lead is disconnected. Turn OFF when
Control blower Off Delay time. Used in conjunction with SW1--- 8.
See Table 10.
Control blower Off Delay time. Used in conjunction with SW1--- 7.
See Table 10.
36
120 MODEL
X
X
X
X
X
X
X
X
X
X
X
X
X
1225
1225
1750
1750
1
1750
2100
1
DESCRIPTION OF USE
W2 close.
humidifier.
Self--- Test is completed.
A06508