Electrostatic Discharge (Esd) Precautions Procedure; Dimensional Drawing - Bryant 383KAV Installation, Start-Up, And Operating Instructions Manual

Table of Contents

Advertisement

"
1
28
2
VENT CONN
7
-IN. DIA HOLE
8
POWER ENTRY
7
-IN. DIA
8
ACCESSORY
3
1
-IN. DIA HOLE
4
"
39
7
8
GAS ENTRY
1
-IN. DIA HOLE
2
THERMOSTAT
WIRE ENTRY
SIDE INLET
"
5
24
16
"
11
16
AIR INLET
NOTES:
1. Two additional
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM–16-in. round or 14
b. For 1200 CFM–20-in. round or 14
c. For 1600 CFM–22-in. round or 14
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific
use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the
bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
UNIT SIZE
024045
036045
024070
036070
042091
048091
036110
048111
060111
048135
060135
060155
* Oval collar
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE
CAUTION: Electrostatic discharge can affect electronic
components. Take precautions during furnace installation
and servicing to protect the furnace electronic control.
Precautions will prevent electrostatic discharges from
personnel and hand tools which are held during the
procedure. These precautions will help to avoid exposing
the control to electrostatic discharge by putting the
furnace, the control, and the person at the same electro-
static potential.
"
1
2
16
1"
"
3
5
8
"
5
12
16
"
13
5
16
"
3
2
8
3"
"
11
16
7
- in. dia holes are located in the top plate.
8
1
x 12-in. rectangle.
2
1
x 19
2
1
x 23
2
→Fig. 1—Dimensional Drawing
TABLE 1—DIMENSIONS (IN.)
A
D
14-3/16
12-9/16
14-3/16
12-9/16
14-3/16
12-9/16
14-3/16
12-9/16
17-1/2
15-7/8
21
19-3/8
17-1/2
15-7/8
21
19-3/8
24-1/2
22-7/8
21
19-3/8
24-1/2
22-7/8
24-1/2
22-7/8
A
D
"
13
16
"
3
5
8
11
2
"
13
5
16
"
3
2
8
TYP 1 "
"
11
16
E
5
TYP
1
-in. rectangle.
2
1
-in. rectangle.
4
E
12-11/16
12-11/16
12-11/16
12-11/16
16
19-1/2
16
19-1/2
23
19-1/2
23
23
1. Disconnect all power to the furnace. DO NOT TOUCH
THE CONTROL OR ANY WIRE CONNECTED TO THE
CONTROL PRIOR TO DISCHARGING YOUR BODY'S
ELECTROSTATIC CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the
furnace chassis which is close to the control. Tools held in
a person's hand during grounding will be satisfactorily
discharged.
3. After touching the chassis you may proceed to service the
control or connecting wires as long as you do nothing that
recharges your body with static electricity (for example; DO
NOT move or shuffle your feet, DO NOT touch un-
grounded objects, etc.).
—2—
AIRFLOW
"
1
2
16
19"
OUTLET
1"
7
-IN. DIA
8
POWER ENTRY
1
1
-IN. DIA
"
2
16
R.H. GAS ENTRY
7
-IN. DIA ACCESSORY
8
1
-IN. DIA THERMOSTAT
2
WIRE ENTRY
SIDE INLET
"
8
"
1
23
4
SIDE RETURN
DUCT LOCATION
VENT CONN
SHIP. WT (LB)
4
4
4
4
4
4
4
4
4
5*
5*
5*
"
13
16
"
1
14
2
"
1
1
4
1 "
A00210
118
120
142
127
124
155
153
173
176
173
187
194