Table 5 – Approved Combustion- -Air and Vent Pipe, Fitting and Cement Materials (U.S.A Only*)
ASTM
SPECIFICATION
(MARKED ON MATERIAL)
D1527
D1785
D2235
D2241
D2466
D2468
D2564
D2661
D2665
F438
F441
F442
F493
F628
F656
F891
*Refer to Page 1 for Canadian installations.
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in property
damage, personal injury, or death.
All combustion- -air and vent pipes must be airtight and
watertight. Pipes must also terminate exactly as shown in Fig.
31 for direct vent (2- -pipe) system or Fig. 32 for ventilated
combustion air option.
An abandoned masonry chimney may be used as a raceway for
properly
insulated
and
supported
applicable) and vent pipes. Each furnace must have its own set of
combustion- -air and vent pipes and be terminated individually, as
shown in Fig. 31 for Direct Vent (2- -Pipe) system or Fig. 32 for
ventilated combustion air option.
A furnace shall not be connected to a chimney flue serving a
separate appliance designed to burn solid fuel.
Other gas appliances with their own venting system may also use
the abandoned chimney as a raceway providing it is permitted by
local code, the current edition of the National Fuel Gas Code and
the vent or liner manufacturer's installation instructions. Care must
be taken to prevent the exhaust gases from one appliance from
contaminating the combustion air of other gas appliances. Do not
take combustion air from inside the chimney when using the
Ventilated Combustion Air option.
CAUTION
!
UNIT MAY NOT OPERATE
Failure to follow this caution may result in intermittent unit
operation.
When vent pipe is exposed to temperatures below freezing,
such as when it passes through an unheated space or when a
chimney is used as a raceway, pipe must be insulated as
shown in Table 7 with Armaflex- -type insulation.
MATERIAL
FITTINGS
PIPE
ABS
Pipe
PVC
Pipe
For ABS
PVC
Pipe
PVC
Fittings
ABS
Fittings
For PVC
ABS
Pipe
Fittings
PVC
Pipe
Fittings
CPVC
Fittings
CPVC
Pipe
CPVC
Pipe
For CPVC
ABS
Pipe
For PVC
PVC
Pipe
combustion- -air
(when
SOLVENT CEMENT AND
PRIMERS
Solvent Cement
Solvent Cement
Solvent Cement
Primer
FURNACE
NOT IN
HORIZONTAL
SECTION
Fig. 24 - - Combustion- -Air and Vent Pipe Diameter
Transition Location and Elbow Configuration
Furnace combustion air and vent pipe connections are sized for
2- -in. pipe. Any pipe size change should be made outside furnace
casing in vertical pipe. The transition has to be made as close to the
furnace as reasonably possible. (See Fig. 24.)
Installation Guidelines for Combustion Air Pipe and Vent Pipe
It is recommended that all pipes be cut, prepared, and preassembled
before permanently cementing any joint.
1. Attach combustion air pipe and vent pipe per instructions in
sections "Combustion Air Pipe" and "Vent Pipe."
2. Working from furnace to outside, cut pipe to required
length(s).
3. Deburr inside and outside of pipe.
4. Chamfer outside edge of pipe for better distribution of
primer and cement.
5. Clean and dry all surfaces to be joined.
6. Check dry fit of pipe and mark insertion depth on pipe.
7. After pipes have been cut and preassembled, apply generous
layer of cement primer to pipe fitting socket and end of pipe
to insertion mark. Quickly apply approved cement to end of
pipe and fitting socket (over primer). Apply cement in a
light, uniform coat on inside of socket to prevent buildup of
excess cement. Apply second coat.
8. While cement is still wet, twist pipe into socket with 1/4
turn. Be sure pipe is fully inserted into fitting socket.
21
DESCRIPTION
Schedule--- 40
Schedule--- 40
For ABS
SDR--- 21 & SDR--- 26
Schedule--- 40
Schedule--- 40
For PVC
DWV at Schedule--- 40 IPS sizes
DWV
Schedule--- 40
Schedule--- 40
SDR
For CPVC
Cellular Core DWV at Schedule--- 40
IPS sizes
For PVC
Cellular Core Schedule--- 40 & DWV
PIPE DIAMETER
TRANSITION IN
VERTICAL SECTION
A93034