Step 6: Electrical Requirements, Connection & Grounding
Prior to servicing appliance, always disconnect
appliance electrical supply cord, if so equipped,
from wall receptacle. If appliance is hard-wired
to power supply, disconnect power to unit by
turning off the proper circuit breaker or discon-
necting the proper fuse.
Chart C: Electrical Supply Circuit Requirements
MODEL NUMBER
PD304
PD36
PD48
For the PD Dual-Fuel Ranges, a neutral supply
wire must be provided from the power source
(breaker/fuse panel) because critical range com-
ponents, including the surface burner spark
reignition module, require 120 VAC to operate
safely and properly. An improper 120/240 VAC
power supply will cause malfunction, damage
this appliance, and possibly create a condition of
shock hazard. If the correct power supply circuit
is not provided, it is the responsibility and obli-
gation of the installer or user to have proper
power supply connected. This must be accom-
plished in accordance with all applicable local
codes and ordinances by a qualified electrician.
CHART D: POWER SUPPLY WIRE–RATING AND SIZE REQUIREMENTS
MODEL
NUMBER
PD304
PD36
PD48
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa.).
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during
any pressure testing of the system at test pressures in excess of 1/2 psig (3.5kPa.).
When checking the manifold gas pressure, the inlet pressure to the regulator should be at leas 6.0" (14.9 mb) W.C.
for natural gas or 11.0" (27.4 mb) for propane.
Do not attempt any adjustment of the pressure regulator.
VOLTAGE
CIRCUIT RATING
120/240 VAC
120/240 VAC
120/240 VAC
VOLTAGE
TEMPERATURE
RATING, MIN.
RATING
300 VAC
Type T or Equal
300 VAC
Type T or Equal
300 VAC
Type T or Equal
CAUTION
Page 15
Dual Fuel range models PD 304, PD36 and PD48 can
be connected or hard-wired to the power supply as
described on Page 16.
FREQUENCY
35 Amps
60 Hz.
40 Amps
60 Hz.
50 Amps
60 Hz.
In the absence of local codes and ordinances,
the power supply connection shall be in accor-
dance with the National Electric Code.
Observe all governing codes and ordinances
when grounding. In the absence of these codes
or ordinances observe National Electrical Code
ANSI/NFPA No. 70 Current Issue. See Pages 16
and 8 for grounding method.
Electrical wiring diagrams and schematics have
been placed in the toe kick area of the range for
access by a qualified service technician.
The PD Dual Fuel Ranges may be connected to
a 120/208 VAC power supply.
CONDUCTOR SIZE, AWG
L1, L2
10
10
8
PHASE
Single
Single
Single
NEUT
GROUND
12
10
12
10
10
8