Vent Clearances and Framing

A. Pipe Clearances to Combustibles
WARNING
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or
other materials.
• National building codes recommend
using attic shield to keep loose materials/
insulation from contacting vent.
Failure to keep insulation or other materials away from
vent pipe may cause fi re.
C L E A R A N C E
C L E A R A N C E
A R O U N D V E R T IC A L
S E C T IO N S
Figure 6.1 Pipe Clearances
Follow vent pipe manufacturer's instructions for all clear-
ances around pipe.
TO P
S ID E A N D
B O T TO M C L E A R A N C E
Heat & Glo • 6000GBV, 6000GBV-IPI • 2104-900 Rev. G • 9/08
B.

Vertical Penetration Framing

Use B-vent manufacturer's fi restops to provide adequate
clearances.
WARNING
Fire Hazard
Keep loose materials or blown insulation from
touching the vent pipe.
National building codes recommend using attic shield to
keep loose materials/ blown insulation from contacting
vent.
Hearth & Home Technologies requires the use of an attic
shield.
15