Heat & Glo 6000GL-IPI-S Owner's Manual

Installation and operation
Hide thumbs Also See for 6000GL-IPI-S:
Table of Contents

Advertisement

Models:
6000GL-IPI-S
6000GL-IPI-R
6000GL-IPILP-S
6000GL-IPILP-R
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000GL-IPI-S

  • Page 1 Homes, CAN/CSA Z240MH, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 NOTICE DO NOT DISCARD THIS MANUAL • Read, understand and follow these instructions for safe installation and operation.
  • Page 2: Congratulations

    INPUT BTUH: ORIFICE ORIFICE SIZE: Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.
  • Page 3: Table Of Contents

    6 Termination Locations A. Vent Termination Minimum Clearances ....21 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Table of Contents 7 Vent Information and Diagrams A.
  • Page 4 D. Contact Information ......70 = Contains updated information. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08...
  • Page 5: Limited Lifetime Warranty

    • Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. Page 1 of 2 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Wood Pellet...
  • Page 6 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 4021-645A 09-01-08...
  • Page 7: Listing And Code Approvals

    Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 C. BTU Specifi cations Models...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    (1/2) in. in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Inspection The state or local gas inspector of the side wall horizon-...
  • Page 9: User Guide

    - A decorative fi rescreen. - Adjustable safety gate. Figure 2.1 General Operating Parts Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 User Guide • Install a switch lock or a wall/remote control with child protection lockout feature.
  • Page 10: Fan Kit (Optional)

    For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 F. Fixed Glass Assembly See Section 14.H. G. Remote Controls, Wall Controls and Wall...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 12: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn continually? Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 This is a result of gas combustion and temperature variations. As the appliance warms, this condensation will disappear.
  • Page 13: Maintenance And Service

    Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Doors, Surrounds, Fronts Frequency: Annually By: Homeowner Tools needed: Protective gloves, stable work surface •...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 • Replace fi replace if fi rebox has been perforated. Control Compartment and Firebox Top Frequency: Annually By: Qualifi...
  • Page 15 Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08...
  • Page 16: Installer Guide

    ON FLOOR OF ATTIC (SECTION 8.C) FRAMING/HEADER (SECTION 5.B) GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Installer Guide HORIZONTAL TERMINATION CAP (SECTION 10.M ) VERTICAL TERMINATION CAP (SECTION 10.J) STORM COLLAR (SECTION 10.H)
  • Page 17: Design And Installation Considerations

    1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 D. Inspect Appliance and Components • Carefully remove the appliance and components from the packaging.
  • Page 18: Framing And Clearances

    1295 1067 Figure 5.1 Appliance Locations Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 NOTICE: Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.
  • Page 19: Constructing The Appliance Chase

    C** Add 12 inches for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 To further prevent drafts, the wall shield and ceiling fi re- stops should be caulked with high temperature caulk to seal gaps.
  • Page 20: Mantel And Wall Projections

    NOT the top of the fi replace. Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Combustible Mantel Legs or Wall Projections TO CEILING Figure 5.4 Clearances to Mantel Legs or Wall Projections...
  • Page 21: Termination Locations

    Over 20/12 to 21/12 ...8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 6 in. (minimum) up to 20 in. HORIZONTAL OVERHANG...
  • Page 22 Figure 6.3 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 (3 FT.) = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED J** = 7 ft.
  • Page 23: Vent Information And Diagrams

    8-1/2 in. (216 mm) vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 7.1). Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Vertical 8-1/2 in. Horizontal Figure 7.1...
  • Page 24: Vent Diagrams

    Two Elbows INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow, to allow the vent pipe to clear the top standoffs.
  • Page 25 305 mm 2 ft. 610 mm 3 ft. 914 mm = 20 ft. (6.1 m) Maximum Figure 7.5 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Max. Min. 2 ft. 610 mm 0 in. 0 mm...
  • Page 26 fl ue restrictor should be used. Figure 7.6 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Flue Restrictor Instructions 1. Remove exhaust shield using a 1/4 inch nut driver by removing the four screws securing it in place (see Figure 7.7).
  • Page 27 Top vent 40 ft vertical with SLP pipe = 4-3 Two Elbows Figure 7.11 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10).
  • Page 28 Top Vent - Vertical Termination - (continued) Three Elbows Figure 7.12 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Elbow only 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 2 ft.
  • Page 29 No Elbow Figure 7.13 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.14 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 = 16 in. (406 mm) Maximum...
  • Page 30 Rear Vent - Horizontal Termination - (continued) Two Elbows Figure 7.15 Three Elbows INSTALLED HORIZONTALLY Figure 7.16 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Maximum Minimum Back to Back 1 ft. 305 mm 90º Elbows 2 ft.
  • Page 31 Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Back to Back 90º Elbows INSTALLED HORIZONTALLY Minimum Maximum 6 in. 152 mm 2 ft.
  • Page 32 Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows INSTALLED Figure 7.20 HORIZONTALLY Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Maximum 2 ft. 610 mm 6 in. 3 ft. 914 mm 1 ft.
  • Page 33: Vent Clearances And Framing

    Sides: 1 in. (25 mm) Figure 8.1 Horizontal Venting Clearances To Combustible Materials Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 B. Wall Penetration Framing Combustible Wall Penetration Whenever a combustible wall is penetrated, you must frame a hole for the wall shield fi...
  • Page 34: Install The Ceiling Firestop

    WARNING! Risk of Fire! DO NOT pack insu- lation around the vent. Insulation must be kept back from the pipe to prevent overheating. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 PIPE Figure 8.3 Installing Ceiling Firestop...
  • Page 35: Install Attic Insulation Shield

    These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 BEND ALL TABS INWARD 90° TO MAINTAIN CLEARANCE...
  • Page 36: Appliance Preparation

    Figure 9.3 Remove the white gasket material covering the seal cap. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Figure 9.4 Remove the seal cap. NOTICE: Once the seal cap has been removed it CANNOT be reattached.
  • Page 37: Rear Vent

    Figure 9.8. HEADER HEADER Figure 9.8 Non-combustible Board Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 D. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic •...
  • Page 38: Installing Vent Pipe (Dvp And Slp Pipe)

    Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Figure 10.1 High Temperature Silicone Sealant Figure 10.3 Figure 10.2...
  • Page 39: Assemble Vent Sections (Slp Pipe Only)

    Figure 10.5 Adding Venting Components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 C. Assemble Slip Sections • Slide the inner fl ue of the slip section into the inner fl ue of the pipe section and the outer fl...
  • Page 40: Secure The Vent Sections

    Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 E. Disassemble Vent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.11.
  • Page 41: Install Decorative Ceiling Components (Slp Only)

    WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 2 in. (51 mm) MIN. BELOW FINISHED CEILING CUT HOLE 1/8 in.
  • Page 42: Install Metal Roof Flashing

    • Caulk the gap between the roof fl ashing and the outside diameter of the pipe. • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 HORIZONTAL OVERHANG VERTICAL Figure 10.15...
  • Page 43: Install Rf4-8

    fl ashing. Figure 10.19 Trim Rubber Boot Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Figure 10.20 Apply Sealant Figure 10.21 Slide Flashing Down, Secure & Apply Sealant...
  • Page 44: Install Vertical Termination Cap

    See Figure 10.24. Figure 10.24 Wall Thimble Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 L. Heat Shield Requirements for Horizontal Termination WARNING! Risk of Fire! To prevent overheating and fi re, heat shields must extend through the entire wall thick- ness.
  • Page 45: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    HRC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield fi restop is required on the exterior side of a combustible wall.
  • Page 46: Gas Information

    • If substituting for these components, please consult local codes for compliance. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance.
  • Page 47: Electrical Information

    110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 B. Intellifi re Ignition System Wiring • Wire the appliance junction box to 110 VAC for proper operation of the appliance.
  • Page 48: Electrical Service And Repair

    WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 IGNITION MODULE 3 VAC GROUND TO FIREPLACE...
  • Page 49: Junction Box Installation

    (1/4 in. male) as shown. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 GRN wire inside box NOTICE: DO NOT wire 110 VAC to wall switch.
  • Page 50: Finishing

    Millimeters Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 B. Facing Material • Metal front faces may be covered with non-combustible materials only.
  • Page 51: Doors

    Finishing materials 1 inch maximum thick. Stop fi nishing material fl ush with opening. Figure 13.5 Overlap Fit Door Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 FINISHING MATERIAL (Includes 1/8 in. opening each side of door) FIGURE 13.4...
  • Page 52: Appliance Setup

    fi rebox heats up. The red color will return when the fi rebox cools. Figure 14.1 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 STEP 1. Place the back piece of refractory in back of the fi rebox.
  • Page 53: Ember Placement

    Use this material to give the appliance a realistic ash bed. • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08...
  • Page 54: Install The Log Assembly

    #1. The left end of this log sits on the burner surface. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Log Assembly: LOGS-6000GL Figure 14.5...
  • Page 55 #1. The thin end of the log rests in the fl at spot molded into the top of log #3. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Figure 14.11 Top View Place log #3 on top of the burner surface in front of the hump.
  • Page 56: Fixed Glass Assembly

    I. Install the Mesh Screen mesh is supplied with the optional doors. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Figure 14. 17 Top View Place log #6 on top of log #5 and log #4. There is a fl at spot molded into the top J.
  • Page 57: Troubleshooting

    C. Module is not grounded. D. Module voltage output / Valve/Pilot solenoid ohms readings. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Corrective Action Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct terminals on module and pilot assembly.
  • Page 58 D. Damaged pilot assembly or contami- nated fl ame sensing rod. E. Module. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Possible Cause Verify all connections to wiring diagram in manual. Verify connections underneath pilot assembly are tight. Verify con-...
  • Page 59: Reference Materials

    Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. GAS LINE ACCESS LEFT SIDE Location Figure 16.1 Appliance Dimensions Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 TOP VIEW FRONT VIEW Location Inches Millimeters...
  • Page 60: Vent Components Diagrams

    (254 mm) DVP-AS (Attic Shield) 10 in. (254 mm) 5 in. (127 mm) DVP-HVS (Vent Support) Figure 16.2 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Effective Length Pipe Inches Millimeters DVP4 DVP6 DVP12...
  • Page 61 (384 mm) 12 in. (305 mm) DVP-TRAP Horizontal Termination Cap DVP-TRAP1 DVP-TRAPK1 DVP-HPC1 Figure 16.3 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 8 in. Heat (203 mm) Shield Term Cap Effective Trap1 Length...
  • Page 62 DVP-TRAPFL Flashing 26 in. 660 mm DVP-HSM-B Extended Heat Shield Figure 16.4 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) 5 in. (127 mm) 13-7/8 in.
  • Page 63 12-1/8 in. (314 mm) 1-5/8 in. (41 mm) DVP-HPC High Performance Cap Figure 16.5 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 7-3/8 in. (187 mm) 17-3/4 in. (451 mm) 7-1/4 in. (184 mm) 5-1/4 in.
  • Page 64 B. Vent Components Diagrams (continued) 8-1/8 in. (206 mm) 15 in. (381 mm) Figure 16.6 DVP vent components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 13 in. Effective Length (330 mm) 5-3/4 to 8-3/8 in. 5-1/2 in.
  • Page 65 45° Elbow Effective Height/ Length SLP PIPE SLP-HVS Horizontal Pipe Support Figure 16.7 SLP Series Vent Components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 6 in. 152 mm Effective Height/Length Pipe inches SLP4 SLP6 SLP12...
  • Page 66 Termination Cap SLP-TRAP1 Horizontal Termination Cap DVP-2SL SLP-DCF-BK Ceiling Firestop Figure 16.8 SLP Series Vent Components Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-TRAP2 Horizontal Termination Cap DVP-HSM-B Extended Heat Shield...
  • Page 67: Service Parts

    6000GL-IPI-R, -S C. Service Parts Beginning Manufacturing Date: May 2006 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08...
  • Page 68 Conversion KIT LP Pilot Orifi ce NG Pilot Orifi ce LP Regulator NG Regulator LP Additional service part numbers appear on following page. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 6000GL-IPI-R, -S COMMENTS PART NUMBER LOGS-6000GL SRV2102-010...
  • Page 69 Orifi ce NG (#53C) Orifi ce LP (#68C) Wall Switch Wire Flex 12 Light Box Cover Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 COMMENTS 6000GL-IPI-R,-S Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ PART NUMBER...
  • Page 70: Contact Information

    D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Heat & Glo, a brand of Hearth & Home Technologies Inc.