E.

Junction Box Installation

If the box is being wired from the OUTSIDE of the
appliance:
• Remove the cover plate located on the outer
shell - right side (see Figure 10.4).
• Install the
Romex™
plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reat-
tach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box/receptacle inward to disengage it from the
outer shell (see Figure 10.4).
• Pull the electrical wires from outside the appli-
ance through this opening into the valve com-
partment.
• Feed the necessary length of wire through the
connector.
F.
Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.5):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using
a minimum of 14-3 with ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire to
the wall switch as shown.
• At the appliance connect the black
(hot), white (neutral) and green
(ground) wires to the junction box as
shown.
• Add a 1/4 inch insulated female con-
nector to the red (switch leg) wire,
route it through the knockout in the
face of the junction box, and connect
to the top fan switch connector (1/4
inch male) as shown.
connector in the cover
Figure 10.5
Heat & Glo • 6000GBV, 6000GBV-IPI • 2104-900 Rev. G • 9/08
Figure 10.4 Junction Box Detail
• Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle to the
outer shell.
M IN IM U M 1 4 -3 AW G
W IT H G R O U N D
J U N C T IO N B O X
R e d
Fan Control Switch Wiring
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
NOTE: Do NOT wire
110VAC to wall switch.
R e d
B lac k
W h ite
G re e n
S W IT C H B O X
S W IT C H
B lac k
W h ite
G re e n
P O W E R
S U P P LY W IR E S