Heat & Glo 6000PLUS Owner's Manual
Heat & Glo 6000PLUS Owner's Manual

Heat & Glo 6000PLUS Owner's Manual

Vented gas fireplace

Advertisement

Quick Links

Model:
6000PLUS
Important operating and
maintenance instruc-
tions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing proper-
ty damage, personal injury, or death.
• Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer's instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indi-
cated on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05
Owner's Manual
Installation and Operation
THE 6000PLUS IS DESIGNED TO BE
USED WITH THE HRV200PLUS ONLY!
THE 6000PLUS WILL NOT VENT CORRECTLY UN-
LESS IT'S CONNECTED TO THE HRV200PLUS.
REFER TO THE HRV200 PLUS INSTALLATION
MANUAL FOR ADDITIONAL INSTALLATION
AND VENTING INSTRUCTIONS.
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert children and adults to hazards of high
temperatures.
• Do NOT operate with protective barriers open or
removed.
• Keep clothing, furniture, draperies and other
combustibles away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fitter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised
by an NFI certified professional.
WARNING
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000PLUS

  • Page 1: Service Parts Lists

    Mobile Homes, CAN/CSA Z240MH. professionals, or technicians supervised This appliance is only for use with the type(s) of gas indi- by an NFI certified professional. cated on the rating plate. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 2: Safety And Warning Information

    STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 3: Table Of Contents

    Step 13 Lighting the Fireplace ..........18 After the Installation ..............18 Section 4: Maintaining and Servicing Your Fireplace..19 Section 5: IPI Troubleshooting Guide........20 = Contains updated information. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 4: Section 1: Approvals And Codes

    Consult your local gas utility for assistance in determining of unconfined space appropriate to the particular installation. the proper orifice for your location. Heat & Glo Quality Systems registered by SGS ICS Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 5: Section 2: Getting Started

    Follow these instructions carefully during the installation to ensure maximum safety and benefit. Failure to follow these instructions will void the owner’s warranty and may present a fire hazard. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 6 2-1/8 (55mm) 36-1/8 (916mm) 6-7/8 6-1/2 (174mm) (1043mm) (165mm) VENT COLLARS STANDOFFS HOOD RATING PLATES & LABELS OUTSIDE CONTROLS GAS ACCESS ELECTRICAL ACCESS Figure 1. Diagram of the 6000PLUS Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 7: Section 3: Installing The Fireplace

    The back of the fireplace may be recessed 21 1/2 inches (546 mm) into combustible construction. The minimum clearance from the top face of the fireplace to combustible finishing materials such as drywall, is one inch (25mm). Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 8: Step 2 Framing The Fireplace

    6000PLUS GAS APPLIANCE. The Intellifire system includes a 3V control valve, electronic module, and intermittent pilot. WARNING: CONTINUOUS 110-120 VAC SER- VICE MUST BE WIRED TO THE FIREPLACE JUNCTION BOX. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 9: Step 6 The Gas Supply Line

    (1/2) psig (3.5 kPa). commercially available, non-corrosive leak check solu- tion. Be sure to rinse off all leak check solution following testing. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 10: Step 8 Wiring The Fireplace

    REPLACED WITH TYPE 105 C RATED WIRE. JUNCTION BOX BLOWER RECEPTACLE GROUND TEMPERATURE SENSOR SWITCH BLOWER 110-120 VAC SENSOR BLOWER SWITCH “FAN” RECEPTACLE SPEED CONTROL Figure 7. Fan Wiring Diagram Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 11 HRV200 PLUS BOARD LOW VOLTAGE VALVE SEE NOTE 1 TO “R1” ON VALVE HRV200 PLUS GROUND BOARD REMOTE TO “R2” ON NEUTRAL CONTROL HRV200 PLUS BOARD Figure 8. Intellifire Wiring Diagram Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 12: Step 9 Sequence Of Operation

    The HRV200PLUS shuts off. e. The HRV200PLUS shuts off. NOTE: The HRV200PLUS can use indoor air instead of the gas appliance for defrost if the optional defrost kit (part# HRV99DEFKIT) is installed. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 13: Step 10 Finishing

    However, ANSI or CAN/CGA testing standards do not require • Pull out and latch the glass clips into the tabs on the glass frame. hearth extensions for gas fireplace appliances. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 14: Glass Specifications

    Replace the glass and run the fireplace for an additional 8 hours. This will help to cure the products used in the paint and logs. EMBER MATERIAL Figure 12. Placement of the Ember Material Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 15: Step 13 Lighting The Fireplace

    LEAVE THIS INSTALLATION MANUAL WITH PERATURE LIMIT SWITCHES. IF, DURING NORMAL THE USER FOR FUTURE REFERENCE. OPERATION THE APPLIANCE CYCLES ON AND OFF, REFER TO “POSSIBLE CAUSE” ITEM #6f IN THE TROUBLESHOOTING GUIDE. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 16: Section 4: Maintaining And Servicing Your Fireplace

    NOTE: DO NOT handle flame. See Figure 5. or attempt to clean the door when it is hot and DO NOT use abrasive cleaners. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 17: Section 5: Ipi Troubleshooting Guide

    Faulty module. Disconnect orange wire on valve. If the pilot turns off then check all connections and continuity - if no fault is found in wiring then replace faulty module. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 18 Check HRV200PLUS blower wheels. Ensure blower wheels are clean - service as necessary per HRV200PLUS manual. Check HRV200PLUS heat exchanger core. Clean and service as necessary per HRV200PLUS manual. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...
  • Page 19 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05...

Table of Contents