Acceptable Vent Configurations; Restrictor Plates - FireplaceXtrordinair 36DV Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for 36DV:
Table of Contents

Advertisement

Use Model GS Direct Vent manufactured by Simpson Dura-Vent only. Follow the installation
instructions included with the vent. For the nearest Simpson Dura-Vent supplier, call
(800) 835-4429. Vent part numbers and descriptions are listed below.
Straight Lengths
908B
6" Pipe Length, Black (interior)
907B
9" Pipe Length, Black (interior)
906
12" Pipe Length, Galvanized
906B
12" Pipe Length, Black (interior)
904
24" Pipe Length, Galvanized
904B
24" Pipe Length, Black (interior)
903
36" Pipe Length, Galvanized
903B
36" Pipe Length, Black (interior)
902
48" Pipe Length, Galvanized
902B
48" Pipe Length, Black (interior)
911B
11" to 14 5/8" Pipe, Adjustable, Black (interior)
Apply high-temperature silicone to the female section of inner pipe (on the lower secton of vent) so
the silicone seals the inner pipe from the outer pipe when the sections are assembled. Slide the
sections together and turn 1/4 turn until the sections lock in place. Install three metal screws through
each joint to lock the outer section in place (see the instructions included with the vent for further
details).
Horizontal sections require a 1/4" rise every 12" of travel
+ Exterior Vent Diameter = 6 5/8", Inner Vent Diameter = 4"
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)

Acceptable Vent Configurations

Restrictor Plates

Certain vent configurations require a restrictor plate. There are four restrictor plates included with
the fireplace. Each restrictor is either a #1 (small) or #2 (large) and is for vertical or horizontal
terminations. On vertical terminations the restrictor plate fits into the final section of pipe (the
section that attaches to the termination). On horizontal terminations the restrictor plate fits into the
vent cap. Failure to install a restrictor plate, when required, will lead to flame lifting and a
potentially dangerous situation.
I
NSTALLATION
Vent Terminations
981
Snorkel Termination (36" rise)
(for basement or raised
termination installations)
982
Snorkel Termination (14" rise)
(for basement or raised
termination installations)
984
Horizontal Square Termination
950
Vinyl Siding Stand-off
991
High Wind Vertical
Termination
(C
.)
ONT
Elbows
990
90• Elbow
990B
90• Elbow, Black (interior)
Penetration, Support Parts
940
Round Support Box/Wall Thimble
941
Cathedral Ceiling Support Box
943
Flashing, 0/12 to 6/12 Roof Pitch
943S
Flashing, 7/12 to 12/12 Roof Pitch
953
Storm Collar
963
Ceiling Firestop
988
Wall Strap
P
13
AGE