Specifications - Toro TMC-212 User Manual

Residential and commercial irrigation system controller
Hide thumbs Also See for TMC-212:
Table of Contents

Advertisement

373-0319 TCM 212 Doc2
12/20/04

Specifications

Cabinet Dimensions:
Indoor Model
7.5" W x 8.5" H x 2" D
(19cm W x 21.6cm H x 5cm D)
Outdoor Model
13.25" W x 9" H x 3.5" D
(33.7cm W x 22.9cm H x 9cm D)
Temperature Range:
Operating: +14°F to +140°F (-10°C to +60°C)
Storage: -22°F to +149°F (-30°C to +65°C)
Power Specifications:
Indoor Model - North America
Plug-in Transformer, Class 2, UL Listed, CSA-certified
• Input: 120 VAC ± 10%, 50/60 H
• Output: 24 VAC ± 10%, 50/60 Hz, 18 VA
Indoor Model - Europe
Plug-in Transformer, TUV Approved
• Input: 230 VAC ± 10%, 50/60 Hz
• Output: 24 VAC ± 10%, 50/60 Hz, 18 VA
Indoor Model - Australia
Plug-in Transformer, SAA Approved
• Input: 240 VAC ± 10%, 50Hz
• Output: 24 VAC ± 10%, 50 Hz, 18 VA
Outdoor Model - North America
Built-in Transformer, Class 2, UL Listed, CSA Certified
• Input: 120 VAC ± 10%, 50/60 Hz
• Output: 24 VAC ± 10%, 50/60 Hz, 20 VA
12:30 PM
Page 41
Outdoor Model - Europe
Built-in Transformer, TUV Approved, SAA Approved
• Input: 230 VAC ± 10%, 50/60 Hz
• Output: 24 VAC ± 10%, 50/60 Hz, 20 VA
Outdoor Model - Australia
Built-in Transformer, SAA Approved
• Input: 240 VAC ± 10%, 50/60 Hz
• Output: 24 VAC ± 10%, 50/60 Hz, 20 VA
Maximum Load Per Station:
0.30A (7 VA) @ 24 VAC
Maximum Load For Pump/Master Valve:
0.30A (7 VA) @ 24 VAC
Total Maximum Output: 0.60A (14 VA) @ 24 VAC
(one station and pump start/master valve)
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents