Connecting A Pump Start Relay; Connecting The Power Source - Toro TMC-212 User Manual

Residential and commercial irrigation system controller
Hide thumbs Also See for TMC-212:
Table of Contents

Advertisement

373-0319 TCM 212 Doc2
12/20/04

Connecting a Pump Start Relay

CAUTION: To prevent controller damage, never
connect an auxiliary pump starter directly to the
controller's 24 VAC output. A 24 VAC 0.30A relay,
must be used to connect the controller to the pump
starter circuit.
1. Route a wire pair from the pump relay into the
controller housing.
2. Connect one wire to the terminal labeled COM (8).
Connect the remaining wire to the terminal labeled
PUMP/MV (9) as shown below.
8
9
Pump Start
Relay
CAUTION: To prevent pump damage due to
prolonged dead-head pressure, connect a jumper wire
from an unused station terminal to a terminal with a
with a valve connected.
Note: Refer to "Pump Control and Well Recovery" section
12
on page 28 for important pump circuit control information.
12:30 PM
Page 12
Jumper Wire
Valve Common Wire

Connecting the Power Source

WARNING:
AC power wiring must be installed and connected
by qualified personnel only. All electrical compo-
nents and installation procedures must comply
with all applicable local and national electrical
codes. Some codes may require a means of discon-
nection from the AC power source installed in the
fixed wiring and having a contact separation of at
least 0.120" (3mm) in the line and neutral poles.
Make sure the power source is OFF prior to con-
necting the controller.
1. Route the power and equipment ground wires from
the power source, through the conduit and into the
controller transformer compartment.
Note: The controller terminal block accepts wire size
up to 12 AWG (4mm
2
).
2. Remove 3/8" (10mm) insulation from the wire ends.
3. Using a small flat blade screwdriver, secure the wires
as shown to the terminal block as follows:
Line or Line 1 (L1) to L, Neutral or Line 2 (L2) to N
and Equipment Ground to
4. Install and secure the transformer compartment
cover.
5. Apply power to the controller.
Note: The display will begin flashing 12:00
button to stop the display from flashing.
.
. Press any
AM

Hide quick links:

Advertisement

Table of Contents
loading