3
. Operation
● Operation after a power failure
• If a power failure or abnormal input power supply occurs, the UPS automatically switches to Battery
Mode, continuing power output from the Power Supply Output Receptacles supplied from the battery.
• The status is displayed and the beeper sounds intermittently to alert the user.
Setting switch 1 can be used to turn the beeper ON/OFF. ➛ Page 32
See also
Status
Battery
indicator
replacement
26
Beep
Output Charging
Intermittent
OFF
ON
4-second
Discharging
intervals
Intermittent
OFF
1-second
ON
Discharging
intervals
OFF
None
OFF
Discharging
Description
In Battery Mode due to power failure or
AC power error.
(Same as above.)
Battery level is low, so output will stop soon.
Battery is dead, so output stopped.
(This is displayed only for a few seconds.)
(
indicates blinking)
Solution
Perform shutdown
operations for the
connected devices
and stop them.
(Same as above.)
Charge the battery.