1.7 MANTEL CLEARANCES

Clearance to a mantelpiece is 279 mm. See Figure 34.
If joints between the finished walls and the heater
surround (top and sides) are sealed, a 150
sealant material must be used. These joints are not
required to be sealed. Only non-combustible material
0
(using 150
C. minimum adhesive, if needed ) can be
applied as facing to the heater surround (see Figure 35).
152
127
102
76
51
279
INSIDE EDGE OF DRESS GUARD OPENING
DRESS GUARD
NOTE: ALL DIMENSIONS ARE SHOWN IN MILLIMETERS
Figure 34.
Figure 35.
0
C. minimum
CEILING
305
279
254
229
203
178
1010
533
507
482
457
431
406
380
355
330
304
HIGH TEMP
(300 F. 150 C. MIN.)
0
0
SEAL JOINT
Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06
23