1.6 BLOWER WIRING

These heaters have a factory installed fan, electrical junc-
tion boxes, variable speed rheostat control switch and tem-
perature sensor switch for the fan. These components are
located behind the lower grille.
Use of the fan requires that the junction box (factory in-
stalled) be connected to 240 VAC service before perma-
nently enclosing the heater. The access hole for connect-
ing the service wires is found on the lower exterior side of
the unit. Figure 32 shows the fan, switches, and fan wiring
diagram. Figure 33 shows the wire connection detail.
22
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE RE-
PLACED, IT MUST BE RE-
PLACED WITH TYPE 105
C
RATED WIRE.
Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06
BLACK
BLACK
BROWN
BLUE
TEMPERATURE
SENSOR SWITCH
GREEN/YELLOW
STRIPE
BLOWER
NOTE: If the supply cord is damaged, it must be re-
placed by the manufacturer, an authorized service
agent, or a similarly qualified person in order to avoid
a hazard.
BLACK
(HOT) BROWN
BROWN
(NEUTRAL) BLUE
BLUE
Figure 33. Wire Connection Detail