Blower Wiring - Heat & Glo ST-HVBI-AU Installation And Operation Instructions Manual

Table of Contents

Advertisement

Figure 32. Fan, Switches and Fan Wiring Diagram

1.6 BLOWER WIRING

These heaters have a factory installed fan, elec-
trical junction boxes, variable speed rheostat
control switch and temperature sensor switch
for the fan. These components are located be-
hind the lower grille. Use of the fan requires
that the junction box (factory installed) be con-
nected to 240 VAC service before permanently
enclosing the heater. The access hole for con-
necting the service wires is found on the lower
exterior side of the unit. Figure 32 shows the
fan, switches, and fan wiring diagram. Figure 33
shows the wire connection detail.
22
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE AP-
PLIANCE MUST BE REPLACED, IT
MUST BE REPLACED WITH TYPE
105º C RATED WIRE.
BROWN
BLUE
Heat & Glo • ST-HVBI-AU • 2082-900 Rev. J • 10/10
BLACK
BLACK
BROWN
BLUE
TEMPERATURE
SENSOR SWITCH
GREEN/YELLOW
STRIPE
BLOWER
BLUE
BROWN
GREEN/YELLOW
NOTE: If the supply cord is damaged, it must be replaced by
the manufacturer, an authorized service agent, or a similarly
qualifi ed person in order to avoid a hazard.
BLACK
(HOT) BROWN
BROWN
(NEUTRAL) BLUE
BLUE
Figure 33. Wire Connection Detail
VARIABLE
SPEED
CONTROL
BLACK
240VAC JUNCTION BOX
BROWN
BLACK