Replace PDA-Board.
J After Carriage works, the Alarm Lamp goes on and "ERROR AUTOGAP" is displayed on LCD.
•
Platen operates normally during initialization?
Yes
No
•
Go to B.
•
Adjust Head Gap. Recovered?
No
Yes
•
End
•
Adjust Core Gap. Recovered?
No
Yes
•
End
•
The cables to PRA-Board CN1, CN3 and PGA-Board CN1 connected properly?
Yes
No
•
Connect the cables properly.
•
The cables to PMA-Board CN2, CN6 and CN8 connected properly?
Yes
No
•
Connect the cables properly.
•
The cables to PHA-Board CN1 and CN9 connected properly?
Yes
No
•
Connect the cables properly.
•
Auto-Gap Slit Sensor and Auto-Gap Slit Disc mounted at the proper positions?
Yes
No
•
Install them properly.
•
The gear existing between Auto-Gap Motor and Platen normal? No tooth broken? No
overloading?
Yes
No
•
Install the gear properly. Replace it if damaged.
•
If the Auto-Gap Motor gear is broken, replace the whole Auto-Gap Motor.
•
Check Auto-Gap Slit Sensor wave form at PRA-Board. No problem?
ø1: Examine between CN3-1 pin and SH4.
157