E Printer operates normally but characters are not printed.
•
Self Diagnosis Printing conducted normally?
Yes
No
•
Replace PMA-Board.
•
The interface cable connected properly?
Yes
No
•
Connect the cable properly.
•
Replace the interface cable. Recovered?
No
Yes
•
End
•
The interface is parallel or serial?
Parallel Serial
•
The serial interface setting adjusted for the system?
Yes
•
Check -12V output at PMA-Board.
Slide Control Block toward outside without unplugging the cables. (Stop sliding when
the cables becomes straight. Do not extend the cables by force.)
Check the voltage between CN5-1 pin and CN5-8 pin. Is -12V output?
Yes
•
The cable between PMA-Board CN6 and PHA-Board CN1 connected properly?
Yes
No
•
Connect the cable properly.
•
Replace the junction cable between PMA-Board CN6 and PHA-Board CN1. Recovered?
No
•
Set it properly.
No
•
Check conduction at the 8 pin on the junction cable between PMA-Board
CN5 and Power Supply Unit Connector DCOUT2.
•
Normal conduction?
Yes
No
•
Replace the cable.
•
Replace Power Supply Unit.
150