8 After initialization, Alarm Lamp goes on and "ERROR (in the upper row), RIBBON JAM (in the lower)"
is displayed on LCD.
•
Ribbon fed during initialization?
Yes
No
•
The cables to PRA-Board CN1 and CN9 connected properly?
Yes
•
The cable to PMA-Board CN2 connected properly?
Yes
•
Check the wave form during ribbon feeding at PRA-Board. No problem?
No
•
Replace Ribbon Motor. Recovered?
No
•
Replace Ribbon Gear Assy. Recovered?
No
•
Replace PRA-Board.
•
XXX of Ink Ribbon Cartridge damaged?
No
•
Connect the cables properly.
No
•
Connect the cable properly.
OVDV: Examine between CN9-6 pin and SH6.
ø1: Examine between CN9-4 pin and SH6.
ø2: Examine between CN9-3 pin and SH6.
ø3: Examine between CN9-2 pin and SH6.
ø4: Examine between CN9-1 pin and SH6.
Yes
•
Replace PMA-Board. Recovered?
No
Yes
•
End
•
Replace the junction cable.
Yes
•
End
Yes
•
End
141