Series; Memory Error - HP ProLight Server Troubleshooting Manual

Hewlett-packard proliant servers troubleshooting guide
Table of Contents

Advertisement

180-Log Reinitialized
Audible Beeps: None
Possible Cause: The IML has been reinitialized due to corruption of the log.
Action: Event message, no action is required.

200 Series

201-Memory Error

Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics
indicated.
203-Memory Address Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics
indicated.
207 - Invalid Memory Configuration Detected. DIMMs installed when no corresponding
processor is detected.
Description: Processor is required to be installed for memory to be used.
Action: Populate the processor socket or remove the DIMM.
207-Invalid Memory Configuration - DIMMs must be installed in pairs or sequentially
Audible beeps: 1 long, 1 short
Possible cause: The system is configured with only one FBDIMM and the system does not support single
FBDIMM mode, or multiple FBDIMMs are installed but were not installed in the proper order.
Action: Do one of the following:
Install a valid FBDIMM pair if the system does not support single channel memory mode.
Remove and install FBDIMMs in the proper order.
207-Invalid Memory Configuration - DIMMs Must be Installed Sequentially
Audible Beeps: 1 long, 1 short
Possible Cause: Installed DIMMs are not sequentially ordered.
Action: Reinstall DIMMs in proper order.
207-Invalid Memory Configuration - DIMM Size Parameters Not Supported.
Audible Beeps: 1 long, 1 short
Possible Cause: Installed memory module is an unsupported size.
Action: Install a memory module of a supported size.
("HP Insight
Diagnostics" on page 61) and replace failed components as
("HP Insight
Diagnostics" on page 61) and replace failed components as
Error messages 103