Other Controller Indicates Different Firmware Version

Description: The other controller in the redundant controller configuration is using a different firmware
version.
Action: Be sure both controllers are using the same firmware revision.

Other Controller Indicates Different Cache Size

Description: The other controller in the redundant controller configuration has a different size array
accelerator.
Action: Be sure both controllers are using the same capacity array accelerator.

Processor Reduced Power Mode Enabled in RBSU

Description: Processors clocked down
Action: If you select the reduced power mode in RBSU, the processor are displayed as their reduced
speed during POST. This message indicates that the RBSU reduced power mode has been enabled and
also indicates the maximum speed for the installed processors.

Processor Not Started (Processor Stalled)

Description: If processor fails to launch or fails after being launched but before completing its
initialization, the processor is not started and this message is displayed. This is likely a defective
processor.

Processor Not Started (Stepping Does Not Match)

Description: If a processor has a stepping different than the bootstrap processor, the processor is not
started, and this message is displayed.

Processor Not Started (Unsupported Processor Stepping)

Description: If a processor has an unsupported stepping, it is not started, and this message is displayed.

Processor Not Supported (Unsupported Core Speed)

Description: If a processor has a core speed that is incompatible with the other installed processors, the
processor is not started, and this message is displayed.

RIS Copies Between Drives Do Not Match

Description: The drives on this controller contain copies of the RIS that do not match. The hard drives in
the array do not have matching configuration information.
Action:
Resolve all other errors encountered.
1.
Obtain the latest version of ADU, and then rerun ADU
2.
If unconfigured drives were added, configure these drives using ACU
3.
on page 54).
If drives or arrays were moved, be sure the movement follows the guidelines listed in the
4.
documentation for the array controller.
("Array Diagnostic
Utility" on page 63).
("Array Configuration
Utility"
Error messages 84