Audible Beeps: None
Possible Cause: Upgrade the Array Accelerator module to a larger size.
Action: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot Z Drive Array Controller - Redundant ROM Reprogramming Failure...
...Replace the controller if this error persists after restarting system.
Audible Beeps: None
Possible Cause: Flash ROM is failing. The controller detected a checksum failure, but is unable to
reprogram the backup ROM.
Action:
Update the controller to the latest firmware version
1.
If the problem persists, replace the controller.
2.
1714-Slot Z Drive Array Controller - Redundant ROM Checksum Error...
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps: None
Possible Cause: The controller flash operation was interrupted by a power cycle, or flash ROM is
failing. The controller detected a ROM checksum error and automatically switched to the backup ROM
image.
Action: If this backup ROM image is a lower version than the originally running image, update the
controller to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred
...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps: None
Possible Cause: The memory is beginning to fail.
Action: If this error persists, replace the controller.
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y: SCSI ID
Z.
Audible Beeps: None
Possible Cause: A hard drive SMART predictive failure condition is detected. It may fail at some time in
the future.
Action:
If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive
and restore all data afterward.
If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in
the array are online.