Page 6
4-4-20 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) ..... 133 4-4-21 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded ..... 135 4-4-22 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK ....... 137 4-4-23 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning ....... 139 4-4-24 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical ......
Overview The HP Insight Management WBEM Providers supply system management data through HP integrated VMware ESXi framework for HP ProLiant server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires HP integrated VMware ESXi. Overview 11...
Ethernet port Overview The following profiles are implemented, and files are installed by this provider. Table 2-1 Overview Implemented Profiles • DMTF: Ethernet Port Profile (DSP1014) v. 1.0.0 • DMTF: Host LAN Network Port Profile (DSP1035)1.0.0 • HP Location Profile 1.0 •...
• SMX_RemoteServiceAccessPoint • SMX_RemoteAccessAvailableToIPEndpoint • SMX_RemoteServiceHostedAccessPoint • SMX_EthernetStatistics • SMX_EthernetPortToStatisticalData • SMX_EthernetPortControllerSoftwareIdentity • SMX_EthernetPortControllerFirmwareIdentity • SMX_EthernetElementSoftwareIdentity • SMX_EthernetElementFirmwareIdentity • SMX_EthernetCollection • SMX_EthernetMemberOfCollection • SMX_EthernetGroupHostedCollection SMX_EthernetPort 2-3-1 SMX_EthernetPort implements the class HP_EthernetPort and describes capabilities and characteristics of each EthernetPort in a monitored system. Table 2-2 Class: SMX_EthernetPort Property name...
Page 14
Table 2-2 Class: SMX_EthernetPort StatusDescriptions StatusDescriptions [0] per OperationalStatus[0]: • Unknown • • Degraded • Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice CreationClassName SMX_EthernetPort DeviceID HPQ:SMX_EthernetPort:<InstanceNum> IdentifyingDescriptions None or HPQ: Spare part number if available OtherIdentifyingInfo None or part number text if available SystemName...
SMX_EthernetDevice 2-3-2 SMX_EthernetDevice implements the class HP_EthernetDevice and associates the enclosures computer system instance to the blades computer system instance. Table 2-3 Class: SMX_EthernetDevice Property name Property implementation HP_EthernetDevice GroupComponent ref: SMX_ComputerSystem (the computer system in which this Ethernet Port resides) PartComponent ref: SMX_EthernetPort (the instance of Ethernet Port in this ComputerSystem)
Table 2-4 Class: SMX_EthernetLANEndpoint Property name Property implementation CIM_ServiceAccessPoint CreationClassName SMX_EthernetLANEndpoint SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem CIM_ProtocolEndpoint Description Text representing of what the operating system labels this endpoint. For example: eth3 On Windows operating systems: Local Area Connection 2 ElementName LAN Endpoint info for OS Exposed Ethernet Port informatiom.
SMX_EthernetPortToLANEndpoint 2-3-5 SMX_EthernetPortToLANEndpoint implements the class HP_EthernetPortToLANEndpoint and associates the Ethernet Port instance to its Ethernet LAN Endpoint instance. Table 2-6 Class: SMX_EthernetLANHostedAccessPoint Property name Property implementation CIM_Dependency CIM_DeviceSAPImplementation HP_EthernetPortToLANEndpoint Antecedent ref: SMX_EthernetPort Dependent ref: SMX_EthernetPortLANEndpoint SMX_EthernetPortController 2-3-6 SMX_EthernetPortController implements the class HP_BladeEnclosureFW and is a logical device corresponding to a hardware Ethernet network controller.
Table 2-7 Class: SMX_EthernetPortController Property name Property implementation SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.Name IdentifyingDescriptions None CIM_Controller CIM_PortController ControllerType 2 (Ethernet) ControllerVersion Hardware revision number of the controller or 0 if unknown SMX_EthernetPortControllerEthernetPort 2-3-7 SMX_PortControllerEthernetPort implements the class HP_PortControllerEthernetPort and associates an Ethernet Port Controller to its controlled Ethernet Ports.
Table 2-9 Class: SMX_EthernetPortControllerPhysicalPackage Property name Property implementation CIM_ManagedSystemElement Name Ethernet Controller Package HealthState 5 (OK), normal operation OperationalStatus 2 (OK), normal operation StatusDescriptions Ethernet Controller Package status: OK CIM_PhysicalElement CanBeFRUed Boolen describing if this individual physical package can be replaced in the field. •...
Table 2-10 Class: SMX_EthernetControllerPhysicalPackageEthernetController Property name Property implementation CIM_Dependency CIM_Realizes HP_EthernetControllerPhysicalPackageEthernetController Antecedent ref: SMX_EthernetPortControllerPhysicalPackage Dependent ref: SMX_EthernetPortController SMX_EthernetControllerLocation 2-3-10 SMX_EthernetControllerLocation implements the class HP_EthernetControllerLocation. It describes the location information of the Ethernet Contoller Physical Package or card. Table 2-11 Class: SMX_EthernetControllerLocation Property name Property implementation CIM_ManagedElement...
Table 2-11 Class: SMX_EthernetControllerLocation Property name Property implementation LocationInfoDesc Array of enums describing values at comparable index in LocationInformation array. LocationInfoDesc[0] per LocationInfornation[0]. Values for embedded devices: • 17 (Embedded) non-blade, non-cellular system & visible RJ45 • 14 (Blade Bay) for blades with LAN on Motherboard •...
Page 23
Table 2-13 Class: SMX_IPProtocolEndpoint Property name Property implementation CIM_ManagedElement ElementName IP Protocol Endpoint info for OS Exposed Ethernet Port informatiom. For example: IP Protocol Endpoint(<instanceNum>) for : 82546GB Gigabit Ethernet Controller port <portNumber> For ESXi, IP Protocol Endpoing information for management network logical interface name.
Page 24
Table 2-13 Class: SMX_IPProtocolEndpoint Property name Property implementation AddressOrigin How the Address was assigned to this IP Protocol Endpoint. • 0 (Unknown) • 3 (Static) • 4 (DHCP) IPv4Address Only initialized if IP interface advertises a valid IPv4 Address. IPv6Address Only initialized if IP interface advertises a valid IPv6 Address.
SMX_IPBindsToEthernetLANEndpoint 2-3-13 SMX_IPProtocolBindsToEthernetLANEndpoint implements the class HP_IPBindsToEthernetLANEndpoint and associates an instance of an IP ProtocolEndpoint with its representative Ethernet LAN Endpoint instance. NOTE: Currently not implemented on VMware ESXi platform. The association information between IP addresses and physical NICs is not available to OEM providers on ESXi. Table 2-14 Class: SMX_IPProtocolBingsToEthernetLANEndpoint Property name...
Table 2-16 Class: SMX_RemoteServiceAccessPoint Property name Property implementation CIM_ManagedElement ElementName A unique description of the gateway, for example: RemoteServiceAccessPoint: Gateway for <interface_name> CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement CIM_ServiceAccessPoint CreationClassName SMX_RemoteServiceAccessPoint Name A unique description of the gateway, for example: RemoteServiceAccessPoint: Gateway for <interface_name>...
Table 2-17 Class: SMX_RemoteAccessAvailableToIPEndpoint Property name Property implementation CIM_RemoteAccessAvailableToElement CIM_RemoteAccessAvailableToElement IsDefault Boolean true if only one default and only one gateway are present. In some systems, you might have order of access constraints if multiple gateways are present. Check OrderOfAccess property for gateway priorities. OrderOfAccess 0 (default) indicates ordering does not apply, othewise numbers indicate priority order of access.
Table 2-19 Class: SMX_EthernetStatistics Property name Property implementation CIM_ManagedElement Caption For Ethernet Ports, same as associated EthernetPort.Caption. Description A description of the instance with unique port number for each port on a particular controller, for example: Ethernet port <PortNumber> on ethernet controller <controller_id>...
Table 2-20 Class: SMX_EthernetPortStatisticalData Property name Property implementation CIM_ElementStatisticalData Key:ManagedElement ref:SMX_EthernetPort Key:Stats ref:SMX_EthernetStatistics HP_EthernetPortStatisticalData SMX_EthernetPortControllerSoftwareIdentity 2-3-20 SMX_EthernetPortControllerSoftwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter driver software of the associated Ethernet Port. NOTE: Currently implemented only on VMware ESXi platform. Table 2-21 Class: SMX_EthernetPortControllerSoftwareidentity Property name...
NOTE: Currently implemented only on VMware ESXi platform. Table 2-22 Class: SMX_EthernetPortControllerFirmwareIdentity Property name Property implementation CIM_ManagedElement Caption Ethernet Port Controller Firmware Description Ethernet Port Controler Firmware details for Model Name, where Model name is the Model name of the Ethernet Adapter.
Table 2-23 Class: SMX_EthernetElementSoftwareIdentity Property name Property implementation ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_EthernetElementFirmwareIdentity 2-3-23 SMX_EthernetElementFirmwareIdentity implements the class CIM_ElementSoftwareIdentity. It represents the association between SMX_EthernetPortController and SMX_EthernetPortControllerFirmwareIdentity. Table 2-24 Class: SMX_EthernetElementFirmwareIdentity Property name Property implementation CIM_ Dependency Antecedent ref:SMX_EthernetPortControllerFirmwareIdentity Dependent...
Table 2-25 Class: SMX_EthernetCollection Property name Property implementation GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: Unknown status for Ethernet Collection Ethernet Collection is OK Ethernet Collection is degraded Ethernet Collection has an Error HP_EthernetCollection SMX_EthernetMemberOfCollection 2-3-25 SMX_EthernetMemberOfCollection associates Ethernet Ports to the Ethernet Collection. Table 2-26 Class: SMX_EthernetMemberofCollection Property name...
Page 33
Table 2-28 Class: Provider Indication Common Properties Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName...
Page 34
Table 2-29 HP_AlertIndication: Network Interface Connectivity Lost Property name Property implementation Description If the Network Interface is an Ethernet Port, the Ethernet Port has transitioned from OK to Error. AlertingManagedElement WBEM Path of the SMX_EthernetPort instance AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID ProviderName...
PCI Device Provider Overview This provider implements the profiles listed to support PCI devices installed in HP servers. The following table details the profiles implemented and files installed by this provider. Table 3-1 Overview Implemented Profiles • DMTF: PCI Device Profile (DSP1075) 1.0.0a 09/2007 •...
Page 37
Table 3-2 Class: SMX_PCIDevice Property name Property implementation CIM_LogicalDevice CreationClassName SMX_PCIDevice DeviceID Unique identifier for this PCI device instance SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SXM_ComputerSystem.Name CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_PCIController Capabilities An array of integers that indicates controller capabilities.
Table 3-2 Class: SMX_PCIDevice Property name Property implementation ClassCode The basic function of the PCI device - some code other than 6 (Bridge). Valid values include but are not limited • 1 (Mass Storage) • 2 (Network) • 3 (Display) •...
Page 40
Table 3-4 Class: HP_PCISlot Property name Property implementation Tag for HP Blade Servers SMX:PCISlot:<bladeNum>:<slotNum> Tag for all other servers SMX:PCISlot:<slotNum> Description Same as Name ElementName Same as Name PoweredOn True —If slot is powered on False—If slot is not powered CIM_PhysicalConnector ConnectorLayout 7 (Slot)
SMX_PCICardInSlot 3-3-4 SMX_PCICardInSlot is used to represent an association between SMX_PCICard and SMX_PCISlot that contains this PCI card. Table 3-5 Class: SMX_PCICardInSlot Property name Property implementation Antecedent References SMX_PCISlot Dependent References SMX_PCICard SMX_RealizesPCIDevice 3-3-5 SMX_RealizesPCIDevice is used to represent an association between SMX_PCIDevice and SMX_PCICard that realizes this PCI device.
SMX_PCILSlotLocation 3-3-8 SMX_PCISLotLocation is used to model PCI slot locations on HP Servers. The Windows specific implementation class is SMX_PCISlotLocation. Table 3-9 Class: SMX_PCISlotLocation Property name Property implementation CIM_ManagedElement Caption Same as ElementLocationTag. Description Same as ElementLocationTag. ElementName Same as ElementLocationTag. CIM_Location Name Unique identifier of the form:...
Table 3-9 Class: SMX_PCISlotLocation Property name Property implementation LocationInfoDesc for BladeSystem servers Array of enumerated values describing context of information at comparable index in LocationInformation array 0 & 1. LocationInfoDesc[0] per LocationInfornation[0]. Blade servers 1 (Mezzanine Slot) 14 (Blade) LocationInfoDesc for all other servers Array of enumerated values describing context of information at comparable index in LocationInformation array 0.
Smart Array Overview The HP Smart Array data sheet describes both host based Smart Array HBAs and externally attached MSA enclosures, such as MSA60/70. NOTE: This provider excludes externally attached MSA controllers, such as MSA500 and fibre attached devices, for example MSA1000 or MSA The following profiles are implemented, and the following files are installed by this provider.
Page 45
Table 4-2 Class: SMX_SAArraySystem (CIM_ComputerSystem) Property name Property implementation ElementName Controller/Storage System name and location Examples: Smart Array in Slot=3, for internal Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement OperationalStatus[0] Overall status of the Array System and attached devices.
Table 4-2 Class: SMX_SAArraySystem (CIM_ComputerSystem) Property name Property implementation CIM_ComputerSystem Dedicated Dedicated[0]: 3 (Storage) Dedicated[1]: 15 (Block Server) IdentifyingDescriptions Other Vendor Specific Name OtherIdentifyingInfo Controller Serial Number Note: EMBEDDED-<id> is reported if there is no Serial Number for device is local i.e embedded on motherboard.
Page 47
Table 4-3 Class: SMX_SAArrayController (CIM_ComputerSystem) Property name Property implementation CreationClassName SMX_SAArrayController Name Controller Serial Number Note: EMBEDDED-<id> is reported if there is no Serial Number for device is local i.e embedded on motherboard. PCISLO-<Slot number> is reported if there is no Serial Number for device is local.
SMX_SAStorageVolume 4-3-3 SMX_SAStorageVolume implements the HPSA_StorageVolume class and represents the Logical Volumes configured on the Smart Array. Table 4-4 Class: SMX_SAStorageVolume (CIM_StorageVolume) Property name Property implementation CIM_ManagedElement ElementName Logical drive number with raid description (for example, Logical Volume 1 (RAID 1+0) CIM_ManagedSystemElement Name VPD Pg83 identifier for the volume.
Table 4-4 Class: SMX_SAStorageVolume (CIM_StorageVolume) Property name Property implementation CIM_Storagevolume NameFormat 2 (VPD83NAA6) HPSA_Storagevolume Accelerator See HP Smart Array Profile Deleteable See HP Smart Array Profile FaultTolerance See HP Smart Array Profile OperationalStatus[0, 1] Volume status. DMTF defined value is populated in index[0] and extended status is poplulated in index[1] per HP Smart Array Profile.
Table 4-5 Class: SMX_SADiskDrive (CIM_DiskDrive) Property name Property implementation SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name TotalPowerOnHours Number of service hours logged for the drive CIM_MediaAccessDevice CIM_DiskDrive HPSA_DiskDrive DriveConfiguration See HP Smart Array Profile DriveHasMNPData See HP Smart Array Profile DriveInterface See HP Smart Array Profile DrivePlacement See HP Smart Array Profile DriveRotationalSpeed...
Table 4-6 Class: SMX_SAStorageExtent (CIM_StorageExtent) Property name Property implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SAStorageExtent DeviceID Opaque ID SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name CIM_StorageExtent BlockSize Block size in bytes ConsumableBlocks Total number of blocks on disk drive ExtentStatus[0] Indicates extended status for the disk drive Possible values:...
Table 4-8 Class: SMX _SAPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Version N/A—Not Available for this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSA_PhysicalPackage SMX_SAArrayControllerPhysicalPackage 4-3-8 SMX_SAArrayControllerPhysicalPackage implements the HPSA_ArrayControllerPhysicalPackage class and represents the physical aspects of any Smart Array controller. There is one instance per HBA or one per controller in an external Storage subsystem.
SMX_SADiskPhysicalPackage 4-3-9 SMX_SADiskPhysicalPackage HPSA_DiskPhysicalPackage class and represents the physical aspects of the disk drive. There is one instance per disk drive. Table 4-10 Class: SMX_SADiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Disk location For example, Port: 1E Box 1 Bay: 5 CIM_ManagedSystemElement Name Disk location...
Table 4-11 Class: SMX_SAStorageEnclosure (HP_StorageEnclosure) Property name Property implementation Name Port: <m> Box: <n>, where <m> is the port and <n> is the box number CIM_PhysicalElement CreationClassName SMX_SAStorageEnclosure Manufacturer Enclosure vendor string N/A, if not available Model Enclosure model string ProLiant 6L6I N/A, if not available PartNumber...
Table 4-12 Class SMX_SAStorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power supplies, fans, and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows: •...
Table 4-13 Class: SMX_SAPortController (CIM_PortController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, Smart Array in Slot=3 Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled)
Table 4-14 Class: SMX_SASPIPort (CIM_SPIPort) Property name Property implementation ElementName Controller name and location Smart Array in Slot=3 Smart Array Embedded Controller =7 embedded controller where 7 is the internal indntifier for the embedded controller CIM_ManagedSystemElement OperationalStatus[0] Port status: • 0 (Unknown) •...
Table 4-16 Class: SMX_SAEnclosureFirmware (CIM_SoftwareIdentity) Property name Property implementation IdentityInfoType CIM:SoftwareFamily HPQ:SoftwareCategory IdentityInfoValue HPQ:<TargetType value> [1] Storage Device VersionString Enclosure firmware string HPSA_EnclosureFirmware SMX_SAPrimordialPool 4-3-16 SMX_SAPrimordialPool implements the HPSA_PrimordialPool class and represents the total raw storage managed by the array controller. There is one instance per array system. Table 4-17 Class: SMX_SAPrimordialPool (CIM_StoragePool) Property name...
Table 4-18 Class: SMX_SAStoragePool (CIM_StoragePool) Property name Property implementation CIM_ManagedElement ElementName Controller name and location: pool identifier (for example, Smart Array in Slot=3: Array 0, or Smart Array Embedded Controller=7 Array 0 for embedded controller where 7 is the internal identifier for the embedded controller) CIM_ManagedSystemElement CIM_LogicalElement...
Table 4-19 SMX_SAMediaAccessStatData (CIM_MediaAccessStatData) Property name Property implementation FailedReadRecovers See HP Smart Array Profile FailedWriteRecovers See HP Smart Array Profile FormatErrors See HP Smart Array Profile HardReadErrors See HP Smart Array Profile HardwareErrors See HP Smart Array Profile HardWriteErrors See HP Smart Array Profile HotPlugCount See HP Smart Array Profile MediaFailures...
Table 4-21 Class: SMX_SADriveCage (CIM_PhysicalPackage) Property name Property implementation ElementName Port <n>, where <n> is the name of the port this drive cage is connected For example, Port J3 CIM_ManagedSystemElement Name Serial Number of drive cage N/A—When serial number is not available CIM_PhysicalElement CreationClassName SMX_SADriveCage...
Table 4-24 Class: SMX_SARedundancySet (CIM_RedundancySet) Property name Property implementation RedundancyStatus 2 (Fully Redundant) 4 (Redundancy Lost) TypeOfSet[0] 4 (Sparing) HPSA_RedundancySet SMX_SAStorageRedundancySet 4-3-24 SMX_SAStorageRedundancySet implements the HPSA_StorageRedundancySet class and represents disk sparing aspect of a RAID configuration. There is an instance for every raid set that has spare drives configured.
Table 4-26 Class: SMX_StorageSpecificCollection (HP_GroupHostedCollection) Property name Property implementation CIM_ManagedElement Caption Storage Array Consolidated Status Description Storage Array Consolidated Status ElementName Storage Array Consolidated Status CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Consolidated status for all array controllers. See section 9.10 Consolidated status example of HP Smart Array profile for details on how this value is calculated.
Table 4-27 Class: SMX_SADriveCageLocation (HP_Location) Property name Property implementation LocationInformation[0] HBA Port identifier Examples: • • • LocationInfoDesc[0] Port HPSA_DriveCageLocation SMX_SAArraySystemLocation 4-3-27 SMX_SAArraySystemLocation implements the HPSA_ArraySystemLocation class and represents a location string for the array system. Table 4-28 Class: SMX_SAArraySystemLocation (HP_Location) Property name Property implementation CIM_ManagedElement...
Table 4-29 Class: SMX_SADiskDriveLocation (HP_Location) Property name Property implementation HPSA_DiskDriveLocation SMX_SAArrayControllerLocation 4-3-29 SMX_SAArrayControllerLocation implements the HPSA_ArrayControllerLocation class and represents a location string for the array controller. Table 4-30 Class: SMX_SArrayControllerLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location Examples: •...
Table 4-31 Class: SMX_SAStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation DeltaReservationDefault DeltaReservationMax DeltaReservationMin ElementType 5 (Storage Pool) NoSinglePointOfFailure True—When number of drives > 1 (For example, pool can be configured for redundancy.) False—When number of drives <= 1 NoSinglePointOfFailureDefault True—When number of drives > 1 (For example, pool can be configured for redundancy.) False—When number of drives <= 1 PackageRedundancyDefault...
Table 4-32 Class: SMX_SAProduct (CIM_Product) Property name Property implementation HPSA_Product SMX_SAStorageEnclosureLocation 4-3-32 SMX_SAStorageEnclosureLocation implements the HPSA_StorageEnclosureLocation class and represents a location string for the enclosure. Table 4-33 Class: SMX_SAStorageEnclosureLocation (HP_Location) Property name Property implementation ElementName Enclosure location Port <m> Box <n>, where <m> is the port and <n> is the box number Caption Enclosure location...
SMX_SASCSIProtocolEndpointSCSIProtocolController 4-3-83 (Association) Table 4-84 Class: SMX_SASCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement) Property name Property implementation AvailableSAP SMX_SASCSIProtocolEndpoint ManagedElement SMX_SASCSIProtocolController SMX_SAStorageEnclosureEnclosureLocation (Association) 4-3-84 Table 4-85 Class: SMX_SAStorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SAStorageEnclosure PhysicalLocation SMX_SAStorageEnclosureLocation Supported indications HP_DeviceIndication: Physical Drive Status Changed to 4-4-1 Table 4-86 HP_DeviceIndication: Physical Drive Status Changed to OK...
Page 87
Table 4-86 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation RecommendedActions No action required. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive status is OK EventCategory 6 (Primary Storage) ProbableCause...
Table 4-86 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk F/W version string...
Page 89
HP_DeviceIndication: Physical Drive Status 4-4-2 Changed to ERROR Table 4-87 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name Property implementation PerceivedSeverity Severity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description Physical drive status has changed to Error AlertingMangedElement WBEM Path of SMX_SADiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType...
Page 90
HP_DeviceIndication: Physical Drive Status 4-4-2 Changed to ERROR Table 4-87 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
HP_DeviceIndication: Physical Drive Status 4-4-2 Changed to ERROR Table 4-87 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name Property implementation VariableValues[] FailureDescription short description of the failure Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.OperationalStatus[1] HP_DeviceIndication DeviceModel Physical Disk Model string...
Page 92
HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-88 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation RecommendedActions No action is recommend ed. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary...
Page 93
HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-88 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
HP_DeviceIndication: Physical Drive Status 4-4-4 Changed to PREDICTIVE FAILURE Table 4-89 HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description Physical drive status has changed to Predictive Failure...
Page 95
HP_DeviceIndication: Physical Drive Status 4-4-4 Changed to PREDICTIVE FAILURE Table 4-89 HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
HP_DeviceIndication: Physical Drive Status 4-4-4 Changed to PREDICTIVE FAILURE Table 4-89 HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE Property name Property implementation VariableValues[] FailureDescription short description of the failure Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive.
Page 97
HPSA_StorageVolumeIndication: Logical Drive 4-4-5 Status Changed to OK Table 4-90 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property name Property implementation RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary...
Page 98
HPSA_StorageVolumeIndication: Logical Drive 4-4-5 Status Changed to OK Table 4-90 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-91 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed to Error.
Page 100
SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-91 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-91 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation DeviceOperationalStatus Current OperationalStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatus[1]: SMX_SAStorageVolume.OperationalStatus[1] (This index is only populated if there is addional Vendor unique status available) DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume...
Page 102
SMX_SAStorageVolumeIndication: Logical Drive 4-4-7 Status Changed to Degraded Table 4-92 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name Property implementation EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of physical drives.
Page 103
SMX_SAStorageVolumeIndication: Logical Drive 4-4-7 Status Changed to Degraded Table 4-92 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated.
SMX_SAStorageVolumeIndication: Logical Drive 4-4-7 Status Changed to Degraded Table 4-92 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name Property implementation DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume DeviceOperationalStatusPrevious[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatusPrevious[1]: SMX_SAStorageVolume.OperationalStatus[1] (This index is only populated if there is addional Vendor unique status available) HP_DeviceIndication: Controller Status Changed to 4-4-8...
Page 105
HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-93 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation HP_AlertIndication Summary Controller status OK EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Array Controller Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-93 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller F/W version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5...
Page 107
HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-94 HP_DeviceIndication: Controller Status Changed to ERROR Property name Property implementation AlertingMangedElement WBEM Path to SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array...
Page 108
HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-94 HP_DeviceIndication: Controller Status Changed to ERROR Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName *...
HP_DeviceIndication: Controller Redundancy state 4-4-10 has been set to Active Table 4-95 HP_DeviceIndication: Controller Redundancy state has been set to Active Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warningl) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller redundancy state has changed from Standby to Active.
Page 110
HP_DeviceIndication: Controller Redundancy state 4-4-10 has been set to Active Table 4-95 HP_DeviceIndication: Controller Redundancy state has been set to Active Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
HP_DeviceIndication: Controller Redundancy state 4-4-10 has been set to Active Table 4-95 HP_DeviceIndication: Controller Redundancy state has been set to Active Property name Property implementation VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel...
Page 112
HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-96 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Controller Redundancy has been lost EventCategory 6 (Primary Storage) ProbableCause 1 (other) ProbableCauseDescription Array Controller Redundance has been lost...
HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-96 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion...
Page 114
HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-97 HP_DeviceIndication: Controller Redundancy has been restored Property name Property implementation PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description Controller has detected that Redundancy has been restored and can communicate with partner controller. AlertingMangedElement WBEM path to the SMX_SAArrayController class.
Page 115
HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-97 HP_DeviceIndication: Controller Redundancy has been restored Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain...
HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-97 HP_DeviceIndication: Controller Redundancy has been restored Property name Property implementation VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Battery Status 4-4-13 Change - OK Table 4-98...
Page 117
HP_DeviceIndication: Controller Battery Status 4-4-13 Change - OK Table 4-98 HP_DeviceIndication: Controller Battery Status Change - OK Property name Property implementation Summary Controller battery status change to OK EventCategory 6 (Primary Storage) ProbableCause 1 (other) ProbableCauseDescription Controller Battery Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication...
HP_DeviceIndication: Controller Battery Status 4-4-13 Change - OK Table 4-98 HP_DeviceIndication: Controller Battery Status Change - OK Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5...
Page 119
HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-99 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation CIM_AlertIndication Description A Smart Array controller Battery status has changed to Not Fully Charged. AlertingMangedElement WBEM path to the SMX_SAArrayController class.
Page 120
HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-99 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-99 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Battery status 4-4-15 changed to Failed...
Page 122
HP_DeviceIndication: Controller Battery status 4-4-15 changed to Failed Table 4-100 HP_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation Summary Controller Battery Status set to Failed. EventCategory 6 (Primary Storage) ProbableCause 92 (battery failure) ProbableCauseDescription Controller Battery Status Changed to Failed NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication...
HP_DeviceIndication: Controller Battery status 4-4-15 changed to Failed Table 4-100 HP_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5...
Page 124
HP_DeviceIndication: Controller Cache Status - OK 4-4-16 Table 4-101 HP_DeviceIndication: Controller Cache status changed to OK Property name Property implementation Description Smart Array Controller Cache Status has changed to a status of OK. AlertingMangedElement WBEM path to the SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType...
Page 125
HP_DeviceIndication: Controller Cache Status - OK 4-4-16 Table 4-101 HP_DeviceIndication: Controller Cache status changed to OK Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
HP_DeviceIndication: Controller Cache Status - OK 4-4-16 Table 4-101 HP_DeviceIndication: Controller Cache status changed to OK Property name Property implementation DeviceModel Array Controller Model string HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-102 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation CIM_Indication IndicationIdentifier...
Page 127
HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-102 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation ProbableCause 35 (Performance Degraded) ProbableCauseDescription Array Controller Cache Status Changed to Temporarily Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-102 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 Smart Array P400 Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller HWManufacturer...
Page 129
HP_DeviceIndication: Controller Cache status— 4-4-18 Permanently Disabled Table 4-103 HP_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation Description Array Controller Cache Status is set to a status of Permanently Disabled. Controller has detected a problem with the cache and has disabled the cache permanently.
Page 130
HP_DeviceIndication: Controller Cache status— 4-4-18 Permanently Disabled Table 4-103 HP_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
HP_DeviceIndication: Controller Cache status— 4-4-18 Permanently Disabled Table 4-103 HP_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Enclosure Power Supply 4-4-19 status changed to Non Redundant Table 4-104 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant...
Page 132
HP_DeviceIndication: Enclosure Power Supply 4-4-19 status changed to Non Redundant Table 4-104 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation HP_AlertIndication Summary Power Supply Status changed to Non-Redundant. EventCategory 17 (Primary Storage Power) ProbableCause 89 (Power Supply Failure) ProbableCauseDescription Redundant Power Supply Status Changed to Non- Redundant...
HP_DeviceIndication: Enclosure Power Supply 4-4-19 status changed to Non Redundant Table 4-104 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
Page 134
HP_DeviceIndication: Enclosure Power Supply 4-4-20 status changed to OK (Redundant) Table 4-105 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation RecommendedActions No action required. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary...
HP_DeviceIndication: Enclosure Power Supply 4-4-20 status changed to OK (Redundant) Table 4-105 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect...
Page 136
HP_DeviceIndication: Enclosure Power Supply 4-4-21 status changed to Redundant Degraded Table 4-106 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP SmartArray RecommendedActions Check status of all enclosure power supplies.
HP_DeviceIndication: Enclosure Power Supply 4-4-21 status changed to Redundant Degraded Table 4-106 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber...
Page 138
HP_DeviceIndication: Enclosure Temperature 4-4-22 sensor status changed to OK Table 4-107 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SmartArray...
HP_DeviceIndication: Enclosure Temperature 4-4-22 sensor status changed to OK Table 4-107 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
Page 140
HP_DeviceIndication: Enclosure Temperature 4-4-23 sensor status changed to Warning Table 4-108 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation Description A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
HP_DeviceIndication: Enclosure Temperature 4-4-23 sensor status changed to Warning Table 4-108 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
Page 142
HP_DeviceIndication: Enclosure Temperature 4-4-24 sensor status changed to Critical Table 4-109 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status has changed to Critical.
Page 143
HP_DeviceIndication: Enclosure Temperature 4-4-24 sensor status changed to Critical Table 4-109 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
HP_DeviceIndication: Enclosure Fan status 4-4-25 changed to OK Table 4-110 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed from a status of Non-OK to a status of OK.
Page 145
HP_DeviceIndication: Enclosure Fan status 4-4-25 changed to OK Table 4-110 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
HP_DeviceIndication: Enclosure Fan status 4-4-26 changed to Degraded Table 4-111 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed to a status of Degraded.
Page 147
HP_DeviceIndication: Enclosure Fan status 4-4-26 changed to Degraded Table 4-111 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the...
HP_DeviceIndication: Enclosure Fan status 4-4-26 changed to Degraded Table 4-111 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Fan status 4-4-27 changed to Failure Table 4-112 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication...
Page 149
HP_DeviceIndication: Enclosure Fan status 4-4-27 changed to Failure Table 4-112 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation Summary Fan status error EventCategory 24 (Primary Storage Cooling) ProbableCause 94 (Fan failure) ProbableCauseDescription Fan Failure NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
Page 150
HP_DeviceIndication: Enclosure Fan status 4-4-27 changed to Failure Table 4-112 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number...
Smart Array View Class Overview The HP Smart Array View Class data sheet describes host based Smart Array HBA’s and the attached devices. The current View Class implementation does not support externally attached Smart Array based MSA devices. For example, MSA500, or MSA20. Class Implementations HPVC_SAController 5-2-1...
Table 5-4 Class: HPVC_SAStorageExtent Property name Property implementation HealthState 0 (Unknown) 5 (OK) 10 (Degraded/Warning) 15 (Minor Failure) 20 (Major Failure) 25 (Critical Failure) 30 (Non-recoverable Error) CIM_LogicalElement Caption Disk Y on HPSA X CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SAStorageExtent DeviceID HPVC_SAStorageExtent-<model>-<serial number> For example, HPVC_SAStorageExtent- HPDG072BB975-3NP2TCCF000098402P95 SystemCreationClassName...
Page 155
Table 5-5 Class: HPVC_SAStorageVolume Property name Property implementation ElementName Logical Volume Y on HPSA X : RAID level : Capacity : Associated Physical Disks : Detailed Status Associated Physical Disks reports a list of physical disks that are associated with this logical volume. Physical disk’s index should match the one reported in HPVC_StorageExtentElement Name.
Base server Overview The SMX Base Server provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, Power Supplies, Processor and Memory (Volatile and/or Non-Volatile Storage).
Page 157
Table 6-2 Class: SMX_ComputerSystem Properties Property name Property implementation CIM_ManagedElement Caption Computer system DNS name returned by uname Description Computer system DNS name returned by uname ElementName Computer system DNS name returned by uname CIM_ManagedSystemElement Status Same as OpertionaStatus (0) OperationalStatus OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of...
Page 158
Table 6-2 Class: SMX_ComputerSystem Properties StatusDescriptions StatusDescriptions[0] contains one of the following corresponding to OperationalStatus[0]: • One or more of the subsystems that make up this computer system have an OperationalStatus value of Unknown. • One or more of the subsystems that make up this computer system have an OperationalStatus value of Other.
Page 159
Table 6-2 Class: SMX_ComputerSystem Properties OtherIdentifyingInfo OtherIdentifyingInfo[0]: <GUID_String> where <GUID_String> is the computer system physical GUID string OtherIdentifyingInfo[1]: <MAC_String> where <MAC_String> is the computer system MAC address OtherIdentifyingInfo[2]: <Model_String>:<Serial Number String> where <Model_String> is the computer system model string; and <Serial Number String> is the computer system physical serial number string OtherIdentifyingInfo[3]: <Tag_String>...
Page 160
Table 6-2 Class: SMX_ComputerSystem Properties PrimaryOwnerName Computer system primary owner name string; initialized to not set. PrimaryOwnerContact Computer system primary owner contact string; initialized to not set). PrimaryOwnerPager Computer system primary owner pager string; initialized to not set. SecondaryOwnerContact Computer system secondary owner contact string; initialized to not set.
SMX_ComputerSystemChassis 6-3-2 SMX_ComputerSystemChassis implements the class HP_ComputerSystemChassis to model the physical system chassis. There is only one instance of SMX_ComputerSystemChassis instantiated on a server. Table 6-4 Class: SMX_ComputerSystemChassis Property name Property implementation CIM_PhysicalElement Unique value for instance, for example 1 CreationClassName SMX_ComputerSystemChassis ElementName...
Table 6-4 Class: SMX_ComputerSystemChassis Property name Property implementation ProductID Computer system product ID string (for example, 123456-123) VirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. VirtualSerialNumber If Synergy is enabled, this will contain the logical Serial Number for the system.
The first numeric value in the VersionString MinorVersion The second numeric value in the VersionString RevisionNumber The third numeric value in the Versionstring VersionString Version of SMX, for example, 02.00.00 Manufacturer Hewlett-Packard Classifications[0] 5 (Instrumentation) IsEntity True TargetOSTypes[0] On ESX, 39(VM) On Linux, 36 (Linux)
Table 6-10 Class: CIM_SoftwareIdentity Property name Property implementation IdentityInfoValue[] IdentityInfoValue[0] will contain the following: HPQ:hp-smx IdentityInfoValue[1] will contain the following: System Management HP_SoftwareIdentity SMX_SMXSoftwareIdentity SMX_SMXInstalledSoftwareIdentity 6-3-9 SMX_SMXInstalledSoftwareIdentity implements the class CIM_InstalledSoftwareIdentity and associates the SMX_ComputerSystem instance and an SMX_SMXSoftwareIdentity instance. Table 6-11 Class: SMX_SMXInstalledSoftwareIdentity Property name...
For example, HPQ:SMX_SystemFirmware:1 MajorVersion The firmware major version MinorVersion The firmware minor version VersionString The firmware version Manufacturer Hewlett-Packard Classifications 11 (Bios/FCode) ClassificationDescriptions System Firmware IdentityInfoValue On ProLiant, this will contain: HPQ:<family_code> where <family_code> is the system ROM family code...
Table 6-13 Class: SMX_SystemInstalledFirmwareIdentity Property name Property implementation SMX_SystemInstalledFirmwareIdentity InstalledSoftware ref:SMX_SystemFirmware System ref: HP_ComputerSystem SMX_SystemElementFirmwareIdentity 6-3-12 HP_SystemElementFirmwareIdentity implements the class HP_ElementSoftwareIdentity and associates the HP_ComputerSystem instance and SMX_SystemFirmware instances. Table 6-14 Class: SMX_SystemElementFirmwareIdentity Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity UpgradeCondition 3 (Owner Upgradeable) ElementSoftwareStatus The ElementSoftwareStatus array will contain the...
Table 6-15 Provider Indication Common Properties Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of the indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName...
Table 6-16 HP_DeviceIndication: WBEM Providers Started Property name Property implementation CIM_AlertIndication Description SMX WBEM Providers have started AlertType 5 (Device Alert) EventID ProviderName HP WBEM RecommendedActions No action is recommended. HP_AlertIndication Summary WBEM Providers started ProbableCause 1 (Other) ProbableCauseDescription WBEM Providers Started HP_DeviceIndication: WBEM Providers 6-4-2 Informational Test Indication...
HP_DeviceIndication: WBEM Providers Warning 6-4-3 Test Indication Table 6-18 HP_DeviceIndication: WBEM Providers Warning Test Indication Property name Property implementation CIM_Indication PerceivedSeverity 3 (Warning) CIM_AlertIndication Description This is a warning test event AlertType 5 (Device Alert) EventID ProviderName HP Test RecommendedActions No action is recommended.
Page 172
HP_DeviceIndication: WBEM Providers Critical Test 6-4-4 Indication Table 6-19 HP_DeviceIndication: WBEM Providers Critical Test Indication Property name Property implementation Summary Test Event ProbableCause 1 (Other) ProbableCauseDescription Test Indication Base server 172...
Overview The following table details these profiles implemented and files installed by this provider. Table 7-1 Overview Implemented Profiles HP CPU Profile (P00106) HP CPU Consolidated Status Profile (P00107) HP CPU Physical Asset Profile (P00108) HP Location Profile (P00124) Namespaces This provider returns instances in the root/hpq namespace.
Page 174
Table 7-2 Class: HP_Processor Properties Property name Property implementation CIM_ManagedElement Caption Processor in ProcessorBaord=a, where a is the slot number Processor in socket=b on System Mainboard, where b is the socket number Processor in Socket=b on ProcessorBaord=a where a is the slot number and b is the socket number Description <processor brand string>...
Page 175
Table 7-2 Class: HP_Processor Properties Property name Property implementation HealthState 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) 15 (Minor Failure), when OperationalStatus[0]=10 (Stopped) 20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure) 25 (Critical Failure), when OperationalStatus[0]=6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled)
Table 7-2 Class: HP_Processor Properties Property name Property implementation NumberOfEnabledCores Number of enabled and operational cores for this processor (for example, 1, 2, 4) Stepping Stepping for processor Role Processor Role Unique ID Unique identifier for processor HP_Processor SMX_ProcessorCapabilities 7-3-2 SMX_ProcessorCapabilities extends the class CIM_ProcessorCapabilities to model the processor capabilities.
Page 177
Table 7-4 Class: SMX_ProcessorCore Property name Property implementation CIM_ManagedElement Caption Processor:p - Core:c, where p is the processor number and c is the core number Description <processor brand string> (x86 Family x Model y Stepping z) (Processor:p - Core:c), where <processor brand string>...
Table 7-4 Class: SMX_ProcessorCore Property name Property implementation EnabledDefault 2 (Enabled) CIM_ProcessorCore InstanceID HPQ:SMX_ProcessorCore:Proc:p Core:c, where p is the processor number and c is the core number. CoreEnabledState 2 (Core Enabled) Characteristics For x86 processors: Characteristics[0]: 3 (32-bit Capable) For x64 processors: ○...
Table 7-5 Class: SMX_HardwareThread Property name Property implementation OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for this CPU 6 (Error), when CPU is disabled through POST error 10 (Stopped), when CPU is disabled through RBSU StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]:...
Page 180
Table 7-6 Class: SMX_CacheMemory Property name Property implementation Caption One of the following: Level x Data Cache, where x is the cache level number Level x Insturction Cache, where x is the cache level number Level x Unified Cache, where x is the cache level number Examples: Level 1 Data Cache...
Table 7-6 Class: SMX_CacheMemory Property name Property implementation CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName SMX_ComputerSystem SystemName Computer system name CreationClassName SMX_CacheMemory DeviceID One of the following: Proc p, Level x <type> Cache, where p is the processor number, x is the cache level number, and <type>...
Table 7-10 Class: SMX_HWThreadComponent Property name Property implementation CIM_Component CIM_ConcreteComponent HP_HWThreadComponent GroupComponent ref: SMX_ProcessorCore PartComponent ref: SMX_HardwareThread SMX_AssociatedProcessorCacheMemory 7-3-10 SMX_AssociatedProcessorCacheMemory extends the class CIM_AssociatedCacheMemory. HP_AssociatedProcessorCacheMemory associates an HP_Processor or an HP_ProcessorCore instance with an HP_CacheMemory instance. Table 7-11 Class: SMX_AssociatedProcessorCacheMemory Property name Property implementation CIM_Dependency...
Table 7-12 Class: SMX_ProcessorCollection Property name Property implementation GroupOperationalStatus GroupOperationalStatus[0] contains the processors consolidated status. GroupOperationalStatus[0] will contain one of the following: 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) 5 (Predictive Failure) 6 (Error) 10 (Stopped) The status values of the processors that make up the overall group operational status are contained in GroupOperationalStatus[1-n].
Table 7-13 Class: SMX_HostedProcessorCollection Property name Property implementation HP_ProcessorGroupHostedCollection Antecedent ref: SMX_ComputerSystem Dependent ref: SMX_ProcessorCollection SMX_MemberOfProcessorCollection 7-3-13 SMX_MemberOfProcessorCollection extends the class CIM_MemberOfCollection and associates the HP_ProcessorCollection instance with an HP_Processor instance. Table 7-14 Class: SMX_MemberOfProcessorCollection Property name Property implementation CIM_MemberOfCollection Member ref: SMX_Processor Collection...
Page 187
Table 7-15 Class: SMX_ProcessorChip Properties Property name Property implementation OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for this CPU 6 (Error), when CPU is disabled through POST error 10 (Stopped), when CPU is disabled through RBSU StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]:...
Table 7-15 Class: SMX_ProcessorChip Properties Property name Property implementation CreationClassName SMX_ProcessorChip ElementName Processor in ProcessorBoard=a” where a is the slot number Processor in socket=b on System Mainboard” where b is the socket number Processor inSocket=b on ProcessorBoard=a” where a is the slot number and b is the socket number Manufacturer processor manufacturer string from SMBIOS (for example, Intel or AMD)
SMX_SystemPhysicalProcessor 7-3-16 SMX_SystemPhysicalProcessor extends the class CIM_Container and associates the HP_ComputerSystemChassis instance with HP_ProcessorChip instances. Table 7-17 Class: HP_SystemPhysicalProcessor Property name Property implementation CIM_Component CIM_Container HP_SystemPhysicalProcessor GroupComponent ref: SMX_ComputerSystemChassis PartComponent ref: SMX_ProcessorChip SMX_ProcessorLocation 7-3-17 SMX_ProcessorLocation implements the class HP_Location which extends the class CIM_Location. For ProLiant systems, processor location is denoted by the use of a slot number designator and a socket number designator.
Page 190
Table 7-18 Class: SMX_ProcessorLocation Property name Property implementation ElementName Processor in ProcessorBaord=a, where a is the slot number Processor in socket=b on System MainBoard, where b is the socket number Processor in Socket=b on ProcessorBoard=a where a is the slot number and b is the socket number CIM_Location Name HPQ:SMX_ProcessorLocation:a, where a is the slot...
Table 7-18 Class: SMX_ProcessorLocation Property name Property implementation LocationInfoDesc If only socket number is available, LocationInfoDesc[0]: 4 (Socket), indicates that the first element of the LocationInformation array contains the socket number If only slot number is available, LocationInfoDesc[0]: 0 (Slot), indicates that the first element of the LocationInformation array contains the slot number If both socket and slot numbers are available, LocationInfoDesc[0]:...
Table 7-20 Provider Indication Common Properties Property name Property implementation IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication...
HP_DeviceIndication: Processor Failed Post 7-4-1 Table 7-21 HP_DeviceIndication: Processor Failed Post Property name Property implementation Description CPU Failed Power on Self Test (POST) AlertType 5 (Device Alert) EventID EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replaced the failed processor HP_AlertIndication Summary CPU Failed Power on Self Test (POST) ProbableCause...
System Fan Overview The SMX System Fan provider implements the classes listed to support fans installed in servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview Implemented Profiles HP Fan Profile 1.0 (P102) HP Location Profile 1.0 (P124) HP Fan Physical Location Profile 1.0 (P115) Namespaces...
Table 8-2 Class: SMX_Fan Property name Property implementation CIM_ManagedElement Caption Short description of this fan from the name displayed by the MP or iLO. For example: Fan 1, Fan 1a. Description Description of this fan, including ElementName, FanType and StatusDescription[0]. For example: elementname provides cooling for fantype.
Table 8-2 Class: SMX_Fan Property name Property implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_CoolingDevice ActiveCooling True CIM_Fan VariableSpeed True—if fan supports variable speed False—if fan does not support variable speed or is unknown HP_Fan FanType Enumeration describing the type of fan (see MOF) SMX_FanCollection...
Table 8-3 Class: SMX_FanCollection Property name Property implementation GroupOperationalStatus[0] Represents the most severe cooling redundancy status and non-fault tolerant fan operational status: 0 (Unknown)—if fan collection status is unknown 2 (OK)—if fans are operating properly 3 (Degraded)—if no SMX_Fan OperationalStatus[0] for all non-fault tolerant fans report 6 (Error) and SMX_FanRedundancy.RedundancyStatus for any cooling redundancy sets report 3 (Degraded...
Table 8-4 Class: SMX_FanRedundancySet Property name Property implementation CIM_SystemSpecificCollection InstanceID Unique identifier for this cooling redundancy instance CIM_RedundancySet MaxNumberSupported Represents the maximum number of fans supported for this redundancy set MinNumberNeeded Represents the minimum number of fans needed to function TypeOfSet 3 (Load Balanced) LoadBalanceAlgorithm...
Table 8-6 Class: SMX_HostedCoolingRedundancySet Property name Property implementation OwningElement References HP_ComputerSystem OwnedElement References HP_FanRedundancy SMX_MemberOfFanCollection 8-3-6 SMX_MemberOfFanCollection is used to represent an association between HP_Fan and HP_FanCollection. Table 8-7 Class: SMX_MemberOfCoolingCollection Property name Property implementation Collection References HP_FanCollection Member References HP_Fan SMX_HostedFanCollection 8-3-7 SMX_HostedFanCollection is used to represent an association between HP_FanCollection and the...
Table 8-10 Class: SMX_FanLocation Property name Property implementation CIM_ManagedElement Caption Fan n, where n represents the fan position of the fan instance Description The location of the fan n. Refer to fan position n printed on the system where n represents the fan postion printed on the system labeling.
Table 8-12 Class: SMX_FanModule Property name Property implementation Caption Short description of this fan from the name displayed by the MP or iLO. For example: Fan 1, Fan 1a Description Fan n provides cooling for FanType. StatusDescription where n represents the number of the fan instance, FanType represents the corresponding string value of the FanType enumeration and StatusDescription represents the value of StatusDescriptions[0]...
Table 8-13 Class: SMX_SystemPhysicalFan Property name Property implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_FanModule SMX_RealizesFan 8-3-13 The SMX_RealizesFan class implements the HP_RealizesFan class and associates the HP_Fan instance with HP_FanModule instances. Table 8-14 Class: SMX_RealizesFan Property name Property implementation Antecedent References HP_FanModule Dependent References HP_Fan...
Table 8-15 Class: SMX_FanSlot Property name Property implementation CIM_PhysicalPackage ConnectorLayout 6 (Slot) Number Where n represents the number of the fan slot SMX_SystemFanSlot 8-3-15 SMX_SystemFanSlot class implements the HP_FanSlot class and association the HP_ComputerSystemChassis instance with HP_FanSlot. Table 8-16 Class: SMX_SystemFanSlot Property name Property implementation GroupComponent...
Table 8-18 Provider Indication Common Properties Property name Property implementation CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication ProviderVersion Provider Version in the format VV.UU.FF. for example, 01.05.00 NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication...
Table 8-19 HP_DeviceIndication: Fan Removed Property name Property implementation AlertingManagedElement WBEM Path of the SMX_Fan instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID ProviderName HP Cooling RecommendedActions Check the fan configuration and ensure that this fan was removed intentionally. HP_AlertIndication Summary Fan removed...
HP_DeviceIndication: Fan Inserted 8-4-3 Table 8-20 HP_DeviceIndication: Fan Inserted Property name Property implementation ProbableCauseDescription Fan Inserted HP_SensorHardwareIndication: Fan Failed 8-4-4 Table 8-21 HP_SensorHardwareIndication: Fan Failed Property name Property implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description A fan has failed. Please check the failed fan and replace if necessary.
HP_SensorHardwareIndication: Fan Repaired 8-4-5 Table 8-22 HP_SensorHardwareIndication: Fan Repaired Property name Property implementation CIM_AlertIndication Description A fan has been repaired. The fan is now operating properly. (FanCaption), where FanCaption is the SMX_Fan.Caption for the fan that has been repaired AlertingManagedElement WBEM path of the SMX_Fan instance representing the failed fan AlertingElementFormat...
HP_DeviceIndication: Fan Degraded 8-4-6 The repaired indication is not supported on ProLiant Systems as the fans do not report a degraded status. Table 8-23 HP_DeviceIndication: Fan Degraded Property name Property implementation EventID ProviderName HP Cooling RecommendedActions Check the degraded fan and replace if necessary. HP_AlertIndication Summary Fan Degraded...
HP_DeviceIndication: Fan Redundancy Reduced 8-4-7 Table 8-24 HP_DeviceIndication: Fan Redundancy Reduced Property name Property implementation EventCategory 23 (System Cooling) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Cooling Redundancy has been Reduced HP_DeviceIndication: Fan Redundancy Lost 8-4-8 Table 8-25 HP_DeviceIndication: Fan Redundancy Lost Property name Property implementation CIM_Indication...
HP_DeviceIndication: Fan Redundancy Restored 8-4-9 Table 8-26 HP_DeviceIndication: Fan Redundancy Restored Property name Property implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description Cooling redundancy for the system has been restored. (RedundancySetCaption), where RedundancySetCaption is SMX_FanRedundancySet. Caption of the cooling redundancy set with restored redundancy AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance...
Page 212
HP_DeviceIndication: Fan Redundancy Failed 8-4-10 The redundancy failed indication is not supported on ProLiant systems since redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Table 8-27 HP_DeviceIndication: Fan Redundancy Failed Property name Property implementation Description Cooling redundancy for the system has failed.
System Power Supply Overview The SMX Power Supply provider implements the HP Power Supply profile to model power supplies in systems. The following table details the profiles implemented and files installed by this provider. Table 9-1 Overview Implemented Profiles HP Power Supply Profile 1.0 (P103) HP Location Profile 1.0 (P124) HP Power Supply Physical Asset Profile 1.0 (P116) Namespaces...
Page 214
Table 9-2 Class: HP_PowerSupply Property name Property implementation CIM_ManagedElement Caption Short description of this power supply from the name displaed by the MP or iLO. For example, Power Supply 1, Power supply 1a Description Description of this power supply, including ElementName, PowerSupplyType and StatusDescription[0].
Table 9-2 Class: HP_PowerSupply Property name Property implementation SystemName SMX_ComputerSystem.Name CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_PowerSupply TotalOutputPower 0 (denotes unknown) HP_PowerSupply PowerSupplyType Enumeration describing the type of power supply (see MOF) SMX_PowerCollection 9-3-2 SMX_PowerCollection is used to model power supply collections on Servers.
Table 9-3 Class: SMX_PowerCollection Property name Property implementation GroupOperationalStatus[0] Represents the most severe power redundancy status and non-fault tolerant power supply operational status: 0 (Unknown) —If power collection status is unknown 2 (OK) —If power supplies are operating properly 3 (Degraded) —If no SMX_PowerSupply.OperationalStatus[0] for all non- fault tolerant power supplies report 6 (Error) and SMX_PowerRedundancySet.RedundancyStatus for any...
Table 9-4 Class: SMX_PowerRedundancySet Property name Property implementation CIM_SystemSpecificCollection InstanceID Unique identifier for this power redundancy instance CIM_RedundancySet MaxNumberSupported The maximum number of power supplies supported for this redundancy set MinNumberNeeded The minimum number of power supplies needed to function TypeOfSet 3 (Load Balanced) LoadBalanceAlgorithm...
Table 9-6 Class: SMX_HostedPowerRedundancySet Property name Property implementation OwningElement References HP_ComputerSystem OwnedElement References HP_PowerRedundancySet SMX_MemberOfPowerCollection 9-3-6 SMX_MemberOfPowerCollection is used to represent an association between HP_PowerSupply and HP_PowerCollection. Table 9-7 Class: SMX_MemberOfPowerCollection Property name Property implementation Collection References HP_PowerCollection Member References HP_PowerSupply SMX_HostedPowerCollection 9-3-7 SMX_HostedPowerCollection is used to represent an association between HP_PowerCollection and...
Table 9-10 Class: SMX_PowerSupplyLocation Property name Property implementation CIM_ManagedElement Caption Power Supply n, where n represents the power supply position printed on the system labeling. Description Description of this power supply location, including the location. For example on Proliant:The location of the power supply n.
SMX_PowerSupplyModule 9-3-11 SMX_PowerSupply is used to model physical power supplies on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Table 9-12 Class: SMX_PowerSupplyModule Property name Property implementation CIM_ManagedElement Caption Short description of this power supply from the name displayed by the MP or iLO.
Table 9-12 Class: SMX_PowerSupplyModule Property name Property implementation RemovalConditions 0(Unknown) 3 (Removable when off) 4 (Removable when on or off) Package Type 6 (PowerSupply) SMX_SystemPhysicalPowerSupply 9-3-12 SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and association the HP_ComputerSystemChassis instance with HP_PowerSupplyModule. Table 9-13 Class: SMX_SystemPhysicalPowerSupply Property name Property implementation...
Table 9-15 Class: SMX_PowerSupplySlot Property name Property implementation ElementName Name of the power supply slot, For example:Power Supply Slot n where n represents the number of the power supply slot. CIM_Managed SystemElement OperationalStatus[0] 2 (OK) – if fan slot is operating properly StatusDescriptions[0] Power Supply slot is operating properly –...
SMX_PowerSupplyInSlot 9-3-16 The SMX_PowerSupplyInSlot class extends the CIM_ElementInConnector class and associates the HP_PowerSupplySlot instance with HP_PowerSupplyModule instances. Table 9-17 Class: SMX_PowerSupplyInSlot Property name Property implementation Antecedent References HP_PowerSupplySlot Dependent References HP_PowerSupplyModule Supported indications Provider Indication Common Properties 9-4-1 The following table describes the properties that are common to all of the SMX Power Supply Provider indications that are implemented for server platforms, where available.
Table 9-18 Provider Indication Common Properties Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication...
HP_DeviceIndication: Power Supply Inserted 9-4-3 Table 9-20 HP_DeviceIndication: Power Supply Inserted Property name Property implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A power supply has been inserted. PowerSupplyCaption), where PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has been inserted. AlertingManagedElement WBEM path of the SMX_PowerSupply instance representing the inserted power supply...
HP_DeviceIndication: Power Supply Failed 9-4-4 Table 9-21 HP_DeviceIndication: Power Supply Failed Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID ProviderName HP Power RecommendedActions Check the failed power supply and replace if necessary. HP_AlertIndication Summary Power supply failed EventCategory 16 (System Power) ProbableCause...
HP_Device Indication: Power Supply Redundancy 9-4-7 Reduced Table 9-24 HP_DeviceIndication: Power Supply Redundancy Reduced Property name Property implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fault tolerant power supply is no longer providing power for a power redundancy set. (RedundancySetCaption), where RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set with reduced redundancy.
HP_DeviceIndication: Power Supply Redundancy 9-4-8 Lost Table 9-25 HP_DeviceIndication: Power Supply Redundancy Lost Property name Property implementation Description Power redundancy has been lost. (RedundancySetCaption), where RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set that lost redundancy. AlertingManagedElement WBEM path of the SMX_WinPowerRedundancySet instance representing the redundancy set where redundancy was lost.
Table 9-26 HP_DeviceIndication: Power SupplyRedundancy Failed Property name Property implementation AlertingManagedElement WBEM path of the SMX_PowerRedundancySet instance representing the redundancy set where redundancy failed AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID ProviderName HP Power RecommendedActions Check the power supply configuration and check the status of the power redundancy.
Page 231
Table 9-27 HP_DeviceIndication: Power Supply Redundancy Restored Property name Property implementation ProviderName HP Power RecommendedActions No action is recommended. HP_AlertIndication Summary Power redundancy restored EventCategory 16 (System Power) ProbableCause 1 (Other) ProbableCauseDescription Power redundancy restored System Power Supply 231...
SMX Profile registration provider Overview 10-1 The following table details the profiles implemented and files installed by this provider. Table 10-1 Overview Implemented Profiles • HP Profile Registration Profile (POO100) Namespaces 10-2 This provider returns instances in the root/hpq namespace. Class implementations 10-3 The classes below describe registration of HP profiles.
Page 233
Table 10-2 Class: SMX_RegisteredProfile Property name Property implementation AdvertiseTypes For VMware 3i 3.5.0: 3 (SLP) InstanceID HPQ:n where n is a unique number OtherRegisteredOrganization NULL for DMTF profiles None for SNIA SMI-S storage profiles RegisteredName Table 3 lists the property values for this class RegisteredOrganization 2 (DMTF) for DMTF profiles 11 (SNIA) for SNIA SMI-S storage profiles...
Page 234
This is the list of all possible SNIA profiles. Some implementations only support a subset of these profiles, so only those subsets are reported. Table 10-4 Property values of SMX_RegisteredProfile for SNIA Profiles Generic Initiator Ports 1.3.0 SNIA Generic Initiator Ports Profile DA Target Ports 1.3.0 SNIA DA Target Ports Profile...
Page 235
Table 10-6 Property Values of SMX_RegisteredProfile for HP WBEM TC Profiles HP Fan 1.0.0 HP Fan Profile HP Power Supply 1.0.0 HP Power Supply Profile HP Memory 1.0.0 HP Memory Profile HP Base Server Physical Asset 1.0.0 HP Base Server Physical Asset Profile HP CPU Physical Asset 1.0.0...
SMX_ExtendsProfile 10-3-2 SMX_ExtendsProfile extends the class CIM_Dependency and associates an extension profile registration and the parent profile it extends. Table 10-7 Class: SMX_ExtendsProfile Property name Property implementation CIM_Dependency HP_ExtendsProfile Antecedent ref: CIM_RegisteredProfile (extended) Dependent ref: HP_RegisteredProfile (extends) SMX_ReferencedProfile 10-3-3 SMX_ReferencedProfile extends the class CIM_ ReferencedProfile and associates an HP profile that references another profile when both are registered in the root\Interop namespace.
System Temperature Sensor Overview 11-1 This provider implements the HP Sensor Profile to model temperature sensors in ProLiant servers. The following table details the profiles implemented and files installed by this provider. Table 11-1 Overview Implemented Profiles HP Sensor Profile 1.0 Use cases 11-2 See HP Sensor Profile for Use Cases.
Page 239
Table 11-2 Class: SMX_NumericSensor Property name Property implementation ElementName Temperature Sensor <sensorID>” where <sensorID> is name displayed by MP or iLO. For example: Temperature Sensor Temp 1 CIM_ManagedSystemElement OperationalStatus[0] 2 (OK)—if temperature reported by the sensor is within normal operating range; 2 (OK)—if temperature reported by the sensor has exceeded its non-critical threshold and has set fans to full speed;...
Table 11-2 Class: SMX_NumericSensor Property name Property implementation CurrentState Normal—if OperationalStatus[0] is 2 (OK) Critical—if OperationalStatus[0] is 6 (Error) PossibleStates Array can contain any of the following values: PossibleStates[0] = Normal PossibleStates[1] = Critical CIM_NumericSensor CurrentReading Current reading of temperature sensor BaseUnits 2 (Degrees C) RateUnits...
Table 11-3 Class: SMX_SensorCollection Property name Property implementation CIM_ManagedElement Caption Temperature Sensor Collection Description This is a collection of temperature sensors. GroupStatusDescription., where GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property ElementName Temperature Sensor Collection CIM_SystemSpecificCollection InstanceID Unique identifier for this sensor collection instance HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Represents the most severe sensor group operational...
Table 11-4 Class: SMX_MemberOfSensorCollection Property name Property implementation Member References SMX_NumericSensor SMX_HostedSensorCollection 11-2-5 SMX_HostedSensorCollection implements HP_HostedSensorCollection and is used to represent an association between SMX_SensorCollection and the computer system that contains the collection. Table 11-5 Class: SMX_HostedSensorCollection Property name Property implementation Antecedent References SMX_ComputerSystem Dependent...
Page 243
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded Property name Property implementation Description A temperature sensor has detected that the temperature has exceeded the normal operating range. (SensorCaption)” where SensorCaption is the SMX_NumericSensor.Caption for the sensor that has failed AlertingManagedElement WBEM path of the SMX_NumericSensor instance representing the temperature sensor detecting the exceeded threshold AlertingElementFormat...
Page 244
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames Contains the temperature sensor threshold property name that sets a value: UpperThresholdNonCritical UpperThresholdCritical UpperThresholdFatal...
Page 245
Table 11-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation Description A temperature sensor has detected that the temperature has returned to a normal operating range. (SensorCaption) where SensorCaption is the SMX_NumericSensor.Caption for the temperature sensor detecting a recovered exceeded threshold. AlertingManagedElement WBEM path of the SMX_NumericSensor instance representing the temperature sensor detecting a...
Page 246
Table 11-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
System memory Overview 12-1 This provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory in ProLiant systems. See HP Advanced Memory Protection Technologies (TC060104TB) and product documentation for your ProLiant Server (available at http://www.hp.com). The following table details the profiles implemented and files installed by this provider.
• SMX_MemoryRedundancySet • SMX_MemoryCollection • SMX_HostedMemoryCollection • SMX_MemberOfMemoryCollection • SMX_MemberOfMemoryRedundancySet • SMX_HostedMemoryRedundancySet • SMX_SystemMemoryModuleSlot • SMX_SystemMemoryBoardSlot SMX_Memory 12-2-1 The class SMX_Memory represents logical memory on ProLiant Servers. There is one instance of this class. Table 12-2 Class: SMX_Memory Property name Property implementation CIM_ManagedElement Caption...
Page 249
Table 12-2 Class: SMX_Memory Property name Property implementation HealthState 5 (OK), when OperationalStatus[0]=2 (OK) 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) Name System Memory CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_Memory...
SMX_SystemMemory 12-2-2 The class SMX_SystemMemory represents an association between SMX_Memory and the computer system that contains the memory. There is one instance of this class. Table 12-3 Class: SMX_SystemMemory Property name Property implementation CIM_SystemDevice HP_SystemMemory GroupComponent ref: SMX_ComputerSystem PartComponent ref: SMX_Memory SMX_SystemMemory SMX_MemoryModule 12-2-3...
Page 251
Table 12-4 Class: SMX_MemoryModule Property name Property implementation OperationalStatus Enumerator indicating the memory module operational status. OperationalStatus[0]: contains overall memory module status OperationalStatus[1]: contains detailed memory module status (as needed) For details, see the Memory Module Status, Table 5. StatusDescriptions StatusDescriptions[0]: contains descriptive text per OperationalStatus[0]: StatusDescriptions[1]: contains descriptive text per...
Page 252
Table 12-4 Class: SMX_MemoryModule Property name Property implementation Description Physical Memory Module Socket=y on MemoryBoard= x, where: x is the board/cartridge number where the memory module is located y is the memory socket number where the memory module is located Physical Memory Module Socket=y on ProcessorBoard=x, where: x the processor board number where the memory...
Page 253
Table 12-4 Class: SMX_MemoryModule Property name Property implementation IsSpeedInMhz The IsSpeedInMHz property is used to indicate if the Speed property or the MaxMemorySpeed contains the value of the memory speed. A value of TRUE shall indicate that the speed is represented by the MaxMemorySpeed property.A value of FALSE shall indicate that the speed is represented by the Speed property.
Table 12-5 Memory Module Status Condition OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Memory module has correctable 3 (Degraded) 5 (Predictive Failure) errors exceeding the condition for Degraded Memory module status: Correctable pre-failure warranty error threshold for pre-failure warranty has been exceeded SMX_MemoryBoard 12-2-4 The class SMX_MemoryBoard represents a physical memory board on ProLiant Servers.
Page 255
Table 12-6 Class: SMX_MemoryBoard Property name Property implementation Name Physical Memory MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Physical Memory ProcessorBoard=x, where x is the processor board/cartridge number where the memory board is located. CIM_PhysicalElement CreationClassName SMX_MemoryBoard...
Table 12-6 Class: SMX_MemoryBoard Property name Property implementation AvailableMemory Size of memory for this board seen by the operating system in MB TotalMemory Total size of memory for this board in MB Table 12-7 Memory Board Status Condition OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Memory board status is unknown...
SMX_MemoryModuleSlot 12-2-6 The class SMX_MemoryModuleSlot represents memory module slots on ProLiant Servers. There will be an instance of this class for each memory module socket in the system (whether the slot is occupied or not). (Note: In the property implementation descriptions below, memory module slots located on the system board will be denoted as being located on Board/cartridge number 0 consistent with ProLiant tradition.) Table 12-9...
Page 258
Table 12-9 Class: SMX_MemoryModuleSlot Property name Property implementation Description Memory Module Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located Memory Module Socket=y on ProcessorBoard=x, where: x is the processor board/cartridge number where the memory slot is located...
SMX_MemoryBoardSlot 12-2-7 The class SMX_MemoryBoardSlot represents memory board slots on ProLiant Servers. There will be an instance of this class for each memory board slot in the system (regardless of the slot occupation). Table 12-10 Class: SMX_MemoryBoardSlot Property name Property implementation CIM_ManagedElement Caption Memory Board Slot MemoryBooard=x, where x is the...
Table 12-10 Class: SMX_MemoryBoardSlot Property name Property implementation ConnectorDescription Memory Board Slot MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Memory Board Slot ProcessorBoard=x, where x is the processor board/cartridge number where the memory board is located. CIM_Slot Number The board/cartridge number where the memory board...
SMX_MemoryModuleSlotOnBoard 12-2-10 The class SMX MemoryModuleSlotOnBoard represents an association between an SMX MemoryModuleSlot and the SMX MemoryBoard that contains it. Table 12-13 Class: SMX_MemoryBoardOnSlot Property name Property implementation CIM_Container HP_MemoryModuleSlotOnBoard SMX_MemoryModuleSlotOnBoard GroupComponent ref: SMX_MemoryBoard PartComponent ref: SMX_MemoryModuleSlot SMX_MemoryModuleSlotLocation 12-2-11 The class SMX_MemoryModuleSlotLocation extends the CIM_Location class and represents memory module slot locations on ProLiant Servers.
Page 262
Table 12-14 Class: SMX_ MemoryModuleSlotLocation Property name Property implementation Description Memory Module Socket Location Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory module slot is located y is the memory socket number where the memory module slot is located Memory Module Socket Location Socket=y on ProcessorBoard=x, where: x is the processor board/cartridge number where the...
Table 12-14 Class: SMX_ MemoryModuleSlotLocation Property name Property implementation LocationInfoDesc LocationInfoDesc[0] = 4 (Socket), indicates that the first element of the LocationInformation array contains the socket number LocationInfoDesc[1] = 5 (Memory Board) , LocationInfoDesc[1] (Processor Board) indicates that the second element of the LocationInformation array contains the board/cartridge number SMX_MemoryModuleSlotLocation SMX_MemoryBoardSlotLocation...
Table 12-15 Class: SMX_ MemoryModuleSlotLocation Property name Property implementation PhysicalPosition Opaque key. Example for memory board/cartridge/processor number 1: FF-FF-FF-FF-01-FF-FF-7A HP_Location ElementLocationTag Opaque key. Example for memory board/cartridge/processor number 1: FF-FF-FF-FF-01-FF-FF-7A ElementLocationTagDesc 9 (Memory Board)/13(Processor Board) LocationInformation LocationInformation[0] text: x, where x is the board/cartridge/processor number LocationInfoDesc LocationInfoDesc[0] = 5 (Memory Board) /...
Table 12-17 Class: SMX_MemoryBoardSlotElementLocation Properties Property implementation CIM_ElementLocation HP_ElementLocation SMX_MemoryBoardSlotElementLocation Element ref: SMX_MemoryBoardSlot PhysicalLocation ref: SMX_MemoryBoardSlotLocation SMX_SystemMemoryModule 12-2-15 The class SMX_SystemMemoryModule represents an association between SMX_MemoryModule and SMX_ComputerSystemChassis. There will be an instance of this class for each memory module slot on the chassis system board (whether the slot is occupied or not).
SMX_MemoryRedundancySet 12-2-17 The class SMX_MemoryRedundancySet represents memory board redundancy on ProLiant servers supporting Advanced Memory Protection (AMP). One instance of this class exists on systems supporting Advanced Memory Protection. This class will not be instantiated on non-AMP systems. Table 12-20 Class: SMX_MemoryRedundancySet Property name Property implementation...
Page 267
Table 12-20 Class: SMX_MemoryRedundancySet Property name Property implementation RedundancyStatus The current memory redundancy status as follows: • 2 (Fully Redundant)—System is operating properly in the Advanced Memory Protection mode given in the TargetConfiguration property. • 3 (Degraded Redundancy)—Degraded Redundancy can occur in either of two conditions: ○...
Table 12-20 Class: SMX_MemoryRedundancySet Property name Property implementation TargetConfiguration The desired or targeted mode of the Advanced Memory Protection system. TargetConfiguration is one of the following: • Advanced ECC, when the system is configured for Advanced ECC mode • RAID, when the system is configured for RAID (XOR) mode •...
Page 269
Table 12-21 Class: SMX_MemoryCollection Property name Property implementation GroupOperationalStatus Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property SMX_MemoryRedundancySet.RedundancyStatus. • If no instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined by the worst-of algorithm for physical memory boards...
SMX_HostedMemoryCollection 12-2-19 The class SMX_HostedMemoryCollection represents an association between SMX_MemoryCollection and the computer system that contains this collection. Table 12-23 Class: SMX_HostedMemoryCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_HostedMemoryCollection SMX_HostedMemoryCollection Antecedent ref: SMX_ComputerSystem Dependent ref: SMX_MemoryCollection SMX_MemberOfMemoryCollection 12-2-20 The class SMX_ MemberOfMemoryCollection represents an association between SMX_MemoryCollection and SMX_MemoryModule or SMX_MemoryBoard.
Table 12-25 Class: SMX_MemberOfMemoryRedundancySet Property name Property implementation SMX_MemberOfMemoryRedundancySet Collection ref: SMX_MemoryRedundancySet Member ref: SMX_MemoryBoard SMX_HostedMemoryRedundancySet 12-2-22 The class SMX_HostedMemoryRedundancySet represents an association between SMX_MemoryRedundancySet and the computer system that contains this redundancy set. Table 12-26 Class: SMX_HostedMemoryRedundancySet Property name Property implementation CIM_OwningCollectionElement HP_HostedMemoryRedundancySet...
SMX_SystemMemoryBoardSlot 12-2-24 The class SMX_SystemMemoryBoardSlot represents an association between SMX_MemoryBoardSlot and SMX_ComputerSystemChassis. There is an instance of this class for each memory board slot in the chassis (regardless of the occupation of the slot). Table 12-28 Class: SMX_SystemMemoryBoardSlot Properties Property implementation CIM_Component CIM_Container HP_SystemMemoryBoardSlot...
Page 273
Table 12-29 Provider Indication Common Properties Property name Property implementation SystemFirmwareVersion Array of firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
Page 274
Table 12-31 SMX_MemoryIndication: Memory Board Error Property name Property implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description A memory board has an error. (MemoryBoardCaption) where MemoryBoardCaption is the SMX_MemoryBoard.Caption for the failing memory board. Table 12-32 SMX_MemoryIndication: Memory Redundancy Degraded Property name Property implementation AlertingManagedElement WBEM Path of SMX_MemoryBoard instance...
Page 275
Table 12-32 SMX_MemoryIndication: Memory Redundancy Degraded Property name Property implementation EventID ProviderName SMXMemory RecommendedActions Check the Advanced Memory Protection configuration and replace the memor board and memory modules as necessary.” HP_AlertIndication Summary Advanced Memory Protection degraded EventCategory 3 (Memory) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Advanced Memory Protection Degraded...
Blade System Lite Overview 13-1 The following profiles are implemented, and the following files are installed by this provider. Table 13-1 Overview Implemented Profiles • HP Blade System Lite Profile 1.0 Namespaces 13-2 This provider returns instances in the root/hpq namespace. Class implementations 13-3 The following classes reside in the local host OS CIMOM on each individual blade system and...
Page 277
Table 13-2 Class: SMX_BladeEnclosureCS Property name Property implementation CIM_ManagedSystemElement OperationalStatus • 0 (Unknown), enclosure status: Unknown • 2 (OK), enclosure status: OK • 3 (Degraded), enclosure status: Degraded • 6 (Error), enclosure status: Error StatusDescriptions StatusDescriptions[0] per OperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown •...
Table 13-2 Class: SMX_BladeEnclosureCS Property name Property implementation NameFormat DNSName HP_BladeEnclosureCS ManagementIPAddress The enclosure’s management IP address ManagementURL The URL of the enclosure’s management web-based user interface ProductID The blade enclosure product name (model) string SerialNumber The blade enclusure serial number string SMX_BladeEnclosureCollection 13-3-2 SMX_BladeEnclosureCollection extends the class HP_GroupSystemSpecificCollection to aggregate the...
Table 13-3 Class: SMX_BladeEnclosureCollection Property name Property implementation GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown • Server Blade Enclosure and Onboard Administrator status: OK • Server Blade Enclosure and Onboard Administrator status: Degraded • Server Blade Enclosure and Onboard Administrator status: Error HP_BladeEnclosureCollection...
Table 13-5 Class: SMX_MemberOfBladeEnclosureCollection Property name Property implementation Member ref: HP_BladeEnclosureCS SMX_BladeEnclosureGroupHostedCollection 13-3-5 SMX_BladeEnclosureGroupHostedCollection extends the class HP_GroupHostedCollection and associates the enclosure’s computer system instance to the blade enclosure collection instance. The following properties are implemented. Table 13-6 Class: SMX_BladeEnclosureGroupHostedCollection Property name Property implementation CIM_Dependency...
VersionString String indicating the blade enclosure firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Server Blade Enclosure Firmware IdentityInfoValue An array in which first element contains the path of the...
Table 13-8 Class: CIM_ElementSoftwareIdentity Property name Property implementation Dependent ref: HP_BladeEnclosureCS SMX_BladeEnclosureInstalledFWIdentity 13-3-8 SMX_BladeEnclosureInstalledFWIdentity associates a blade enclosure to its corresponding installed firmware. The following table lists the properties implemented. Table 13-9 Class: SMX_BladeEnclosureInstalledFWIdentity Property name Property implementation CIM_InstalledSoftwareIdentity HP_BladeEnclosureInstalledFWIdentity System ref: HP_BladeEnclosureCS InstalledSoftware...
Table 13-10 Class: SMX_BladeCSLocation Property name Property implementation ElementLocationTagDesc 24 (Blade) LocationInformation LocationInformation[0]: The blade bay number within the enclosure LocationInfoDesc LocationInfoDesc[0]: 14 (Blade Bay) SMX_BladeCSElementLocation 13-3-10 SMX_BladeCSElementLocation is used to represent an association between CIM_Location and CIM_ManagedElement. Table 13-11 Class: HP_ElementLocation Property name Property implementation...
FC HBA Overview 14-1 This provider implements the HP FC HBA Profile which describes the behavior of Fibre Channel host adapters supporting the SCSI (FCP) command set. A Fibre Channel adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports.
Table 14-3 Class: SMX_FCHBAFCPort Property name Property implementation PortType 1 (Other) Speed One of (in Bits per Second): • • 1000000000 • 2000000000 • 10000000000 UsageRestriction 4 (not restricted) CIM_NetworkPort LinkTechnology 4 (FC) PermanentAddress PortWWN PortNumber Port number SupportedMaximumTransmissionUnit Port maximum frame size SMX_FCHBAPortController 14-3-3 SMX_FCHBAPortController is a logical device corresponding to a hardware network port controller.
Table 14-4 Class: SMX_FCHBAPortController Property name Property implementation SystemName Opaque CIM_Controller CIM_PortController ControllerType 4 (FC) SMX_FCHBAFCPortStatistics 14-3-4 SMX_FCHBAFCPortStatsitics represents statistics for a Fibre Channel port. In the following table HBAAPI_PORTSTATISTICS prefix refers to the HBA API HBA_PORTSTATISTICS structure. This information comes directly for the HBA and is not altered. Table 14-5 Class: SMX_FCHBAFCPortStatistics Property name...
Table 14-5 Class: SMX_FCHBAFCPortStatistics Property name Property implementation PrimitiveSeqProtocolErrCount HBAAPI_PORTSTATISTICS.PrimitiveSeqProtocolErrCoun SMX_FCHBALogicalPortGroup 14-3-5 A collection of one or more ports logically grouped for administrative, discovery and topology purposes. Table 14-6 Class: SMX_FCHBALogicalPortGroup Property name Property implementation CIM_ManagedElement Description Grouping of all FC Ports for this HBA Caption Logical Port Group ElementName...
Table 14-7 Class: SMX_FCHBAPhysicalPackage Property name Property implementation OperationalStatus[] 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) CIM_PhysicalElement CreationClassName SMX_FCHBAPhysicalPackage Manufacturer Manufacturer Model Model OtherIdentifyingInfo Location; PCI Slot x where x is the PCI slot number or PCI Mezzanine=x where x is the Mexannine slot number SerialNumber Serial Number...
SMX_FCHBASoftwareIdentityDrv 14-3-8 Table 14-9 Class: SMX_FCHBASoftwareIdentityDrv Property name Property implementation CIM_ManagedElement Caption FC HBA Driver Description Product Name Device Driver where product name is the product name of the HBA. ElementName FC HBA Driver CIM_ManagedSystemElement Name NodeWWN CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FC HBA Driver Classifications 2 (Driver)
Table 14-10 Class: SMX_FCHBAFirmwareIdentityFW Property name Property implementation CIM_SoftwareIdentity ClassificationDescriptions FC HBA Firmware Classifications 10 (firmware) InstanceID HPQ:WWN: <instanceNum> where <instanceNum> is the port controller instance number for the same adapter Manufacturer Manufacturer SerialNumber Serial number VersionString Firmware version SMX_FCHBAFirmwareIdentityBIOS 14-3-10 SMX_FCHBAFirmwareIdentityBIOS represents adapter BIOS associated with the Fibre Channel port controller.
Table 14-11 Class: SMX_FCHBA_FirmwareIdentityBIOS Property name Property implementation MajorVersion MinorVersion RevisionNumber HP_SoftwareIdentity SMX_FCHBAGroupSystemSpecificCollection 14-3-11 SMX_FCHBAGroupSystemSpecificCollection is used to represent the group status of all Fibre Channel ports. Table 14-12 Class: SMX_FCHBAGroupSystemSpecificCollection Property name Property implementation CIM_ManagedElement Caption FC HBA Consolidated Status Description Consolidated status for HP FC HBAs ElementName...
SMX_FCHBA_ComputerSystemFCPort is used to represent an association between SMX_FCHBA_ComputerSystem and HPFCHBA_FCPort. Table 14-13 Class: SMX_FCHBA_ComputerSystemFCPort Property name Property implementation CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemFCPort GroupComponent ref:SMX_FCHBAComputerSystem PartComponent ref:SMX_FCHBAFCPort SMX_FCHBAComputerSystemPortController 14-3-13 SMX_FCHBA_ComputerSystemPortController is used to represent an association between SMX_FCHBA_ComputerSystem and SMX_FCHBAPortController. Table 14-14 Class: SMX_FCHBAComputerSystemPortController Property name Property implementation...
Table 14-15 Class: SMX_FCHBAComputerSystemLogicalPortGroup Property name Property implementation Dependent ref:SMX_FCHBALogicalPortGroup SMX_FCHBAComputerSystemSoftwareIdentityDrv 14-3-15 SMX_FCHBA_ComputerSystemSoftwareIdentityDrv is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASoftwareIdentityDrv. Table 14-16 Class: SMX_FCHBA_ComputerSystemSoftwareIdentityDrv Property name Property implementation CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemSoftwareIdentityDrv InstalledSoftware ref:SMX_FCHBASoftwareIdentityDrv System ref:SMX_FCHBAComputerSystem SMX_FCHBA_FCPortFCPortStatistics 14-3-16 SMX_FCHBA_FCPortFCPortStatistics is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAFCPortStatistics.
Table 14-18 Class: SMX_FCHBA_FCPortLogicalPortGroup Property name Property implementation CIM_MemberOfCollection SMX_FCHBAFCPortLogicalPortGroup Collection ref:SMX_FCHBALogicalPortGroup Member ref:SMX_FCHBAFCPort SMX_FCHBAPortControllerFCPort 14-3-18 SMX_FCHBAPortControllerFCPort is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFCPort. Table 14-19 Class: SMX_FCHBAPortControllerFCPort Property name Property implementation CIM_Dependency CIM_ControlledBy SMX_FCHBAPortControllerFCPort Antecedent ref:SMX_FCHBAPortController Dependent ref:SMX_FCHBAFCPort SMX_FCHBAPhysicalPackagePortController...
SMX_FCHBASoftwareIdentityDrvPortController is used to represent an association between SMX_FCHBAPortController and SMX_FCHBASoftwareIdentityDrv. Table 14-21 Class: SMX_FCHBASoftwareIdentityDrvPortController Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity SMX_FCHBASoftwareIdentityDrvPortController Antecedent ref:SMX_FCHBASoftwareIdentityDrv Dependent ref:SMX_FCHBAPortController SMX_FCHBAPortControllerFirmwareIdentityFW 14-3-21 SMX_FCHBAPortControllerFirmwareIdentityFW is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFirmwareIdentityFW. Table 14-22 Class: SMX_FCHBAPortControllerFirmwareIdentityFW Property name Property implementation...
SMX_FCHBAProductPhysicalComponent 14-3-23 SMX_FCHBAProductPhysicalComponent is used to represent an association between SMX_FCHBA_Product and SMX_FCHBAPhysicalPackage. Table 14-24 Class:SMX_FCHBAProductPhysicalComponent Property name Property implementation CIM_Component CIM_ProductPhysicalComponent SMX_FCHBAProductPhysicalComponent GroupComponent ref:SMX_FCHBAProduct PartComponent ref:SMX_FCHBAPhysicalPackage SMX_FCHBASystemPackaging 14-3-24 SMX_FCHBASystemPackaging is used to represent an association between SMX_FCHBAPhysicalPackage and SMX_FCHBAComputerSystem. Table 14-25 Class:SMX_FCHBASystemPackaging Property name...
Table 14-26 Class: SMX_FCHBAGroupHostedCollection Property name Property implementation SMX_FCHBA_GroupHostedCollection Antecedent ref:SMX_ComputerSystem Dependent ref:SMX_FCHBAGroupSystemSpecificCollection SMX_FCHBAFCPortGroupSystemSpecific 14-3-26 SMX_FCHBAFCPortGroupSystemSpecific is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAGroupSystemSpecificCollection. Table 14-27 Class: SMX_FCHBA_FCPortGroupSystemSpecific Property name Property implementation CIM_MemberOfCollection SMX_FCHBAFCPortGroupSystemSpecific Collection ref:SMX_FCHBAGroupSystemSpecificCollection Member ref:SMX_FCHBAFCPort SMX_FCHBALocation 14-3-27 SMX_FCHBALocation is used to specify the location of the HBA, PCI Slot number.
SMX_FCHBAPhysicalElementLocation 14-3-28 SMX_FCHBAPhysicalElementLocation is used to represent an association between the SMX_FCHBAPhysicalPackage and SMX_FCHBALocation. Table 14-29 Class: SMX_FCHBAPhysicalElementLocation Property name Property implementation CIM_ElementLocation SMX_FCHBAPhysicalElementLocation Element ref:SMX_FCHBAPhysicalPackage PhysicalLocation ref:SMX_FCHBALocation SMX_FCHBASCSIProtocolController 14-3-29 SMX_FCHBASCSIProtocolController represents a protocol controller that manages a SCSI interface. This class is used for backward compatibility with SMI-S 1.0.
Table 14-32 Class: SMX_FCHBAComputerSystemSCSIProtocolController Property name Property implementation CIM_SystemDevice SMX_FCHBAComputerSystemSCSIProtocolController GroupComponent ref:SMX_FCHBAComputerSystem PartComponent ref:SMX_FCHBASCSIProtocolController SMX_FCHBAFCPortSCSIProtocolEndpoint 14-3-32 SMX_FCHBAFCPortSCSIProtocolEndpoint is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBASCSIProtocolEndpoint. Table 14-33 Class: SMX_FCHBAFCPortSCSIProtocolEndpoint Property name Property implementation CIM_Dependency CIM_DeviceSAPImplementation SMX_FCHBAFCPortSCSIProtocolEndpoint Antecendent ref:SMX_FCHBAPort Dependent ref:SMX_FCHBASCSIProtocolEndpoint SMX_FCHBASCSIProtocolControllerFCPort...
Table 14-35 Class: SMX_ FCHBASystremServiceAccessPoint Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedAccessPoint SMX_FCHBASysteServiceAccessPoint Antecendent ref:SMX_FCHBAComputerSystem Dependent ref:SMX_ FCHBASCSIProtocolEndpoint SMX_FCHBAConcreteIdentity 14-3-35 SMX_FCHBAConcreteIdentity is used to represent an association between SMX_ComputerSystem and SMX_FCHBAComputerSystem. Table 14-36 Class: SMX_ FCHBAConcreteIdentity Property name Property implementation CIM_LogicalIdentity CIM_ConcreteIdentity SMX_FCHBAConcreteIdentity...
Management Processor Lite Overview 15-1 The profiles are implemented, and the following files are installed by this provider. Table 15-1 Overview Implemented Profiles • HP Management Processor (MP) Lite Profile 1.0 Namespaces 15-2 This provider returns instances in the root/hpq namespace. Class implementations 15-3 The following classes are implemented for HP server platforms where available.
Page 305
Table 15-2 Class: SMX_ManagementProcessor Property name Property implementation Description Description of the Management Processor in the format: <X> HP Management Processor - <product name> where <X> indicates the MP Is Active or Inactive/Disabled and <product name> is the name of the MP product (same as the product name in property ElementName) For example, Active HP Management Processor –...
Page 306
Table 15-2 Class: SMX_ManagementProcessor Property name Property implementation OperationalStatus Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor (MP) Lite Profile for specific descriptions of when each value is populated). • OperationalStatus[0] contains MP operational status: ○...
Page 307
Table 15-2 Class: SMX_ManagementProcessor Property name Property implementation HealthState • 0 (Unknown), when OperationalStatus[0]=0 (Unknown), or when software interface fails • 5 (OK), normal operation • 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) • 20 (Major failure), when OperationalStatus[0]=6 (Error) Note: When a Management processor is disabled (refer to property EnabledState) HealthState will always report a state of 5 (OK) so as not to contribute negatively to overall system status.
Page 308
Table 15-2 Class: SMX_ManagementProcessor Property name Property implementation ControllerType Enumerator indicating the model or type of management processor (see the HPWmiMgmtProcLite.mof file). • 0 (Unknown) • 1 (Other) • 2 (PCI Board-Remote Insight Lights Out Edition II (RILOE II)) • 3 (Embedded Integrated Lights Out Controller (iLO)) •...
VersionString String indicating the MP firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Management Processor Firmware IdentityInfoValue An array in which first element contains the path of the...
Table 15-4 Class: SMX_MPCollection Property name Property implementation Caption Management Processor Collection GroupOperationalStatus Describes the group operational status of the management processor collection (refer to HP Management Processor (MP) Lite Profile). The group operational status represents the ‘worst-of’ algorithm for all individual MP statuses in HP_ManagementProcessor.OperationalStatus[0].
SMX_MPComponentCS 15-3-5 SMX_MPComponentCS implements the class HP_MPComponentCS, and associates a management processor subsystem to the scoping computer system that contains it. The following properties are implemented. Table 15-6 Class: SMX_MPComponentCS Property name Property implementation CIM_Component CIM_SystemComponent CIM_ComponentCS HP_MPComponentCS GroupComponent ref: HP_ComputerSystem PartComponent ref: HP_ManagementProcessor SMX_MPMemberOfCollection...