To Replace The Power Cord - Dimplex EWM-COPPER Parts & Service Manual

Wall mounted electric fireplace
Hide thumbs Also See for EWM-COPPER:
Table of Contents

Advertisement

If the unit was operating prior to servicing allow at least 10 minutes for light bulbs
and heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the
risk of electric shock or damage to persons.

TO REPLACE THE POWER CORD

1. Unplug the unit from the outlet.
2. Remove the two mounting screws from the bottom front of the heater
assembly.
3. Loosen but do not remove the four heater and light assembly mounting
screws located on the bottom sides of the wall mounted electric fireplace.
4. Slide the heater and light assembly forward to release it from the bottom
of the wall mounted electric fireplace.
5. Place heater and light assembly on a flat surface and remove the six
screws from the upper sides and back of the assembly.
6. Separate the flicker motor and light assembly from the lower assembly.
7. Locate and disconnect the power cord wiring connections noting their
original locations.
8. With needle nose pliers grasp the power cord strain relief grommet from
inside the lower cover and push while twisting to remove.
9. Pull the power cord out through the hole in the lower cover.
10. Install the new power cord through the hole in the lower cover and connect
all of the wiring connections in their original locations.
11. Install the power cord retaining grommet on the power cord and insert into
the hole in the lower cover.
12. Reassemble in the reverse order as above.
16