TROUBLE SHOOTING GUIDE

GENERAL

Problem
Probable Cause
Solution
Service Manual Reference
Problem
Probable Cause
Solution
Service Manual Reference
Problem
Probable Cause
Solution
Service Manual Reference
Circuit breaker trips or fuse blows when the unit is
turned on.
Improper circuit current rating.
Additional appliances may exceed the current rating
of the circuit breaker or fuse. Plug the unit into
another outlet or install on a dedicated circuit with a
15 amp rating. If the unit continues to trip circuit
breakers or blow fuses check all wiring for loose
connections, repair/replace as necessary.
Page 3
Plug or power cord gets warm.
Normal operation or defective cord.
Under normal operation with the heater on, the plug
or cord may get slightly warm to the touch. If the plug
or cord gets too hot to touch, turn the unit off and plug
it into another outlet. If the problem persists replace
the cord assembly.
Page 13
Lights dim in room while the unit is in operation.
Unit is drawing close to circuit current rating.
Move the unit to another outlet or install on a
dedicated circuit with a 15amp rating.
Page 3