Denso AT27Q-SB User Manual page 124

2d code handy scanner
Table of Contents

Advertisement

Control
Commands
Scanner
LR
(Note 3)
IMAGEOUT
U1
U2
U3
U4
U5
U6
U7
U8
PW
(Note 5)
VER
VERF
E
ID
TMON
(Note 6)
TMOFF
(Note 6)
ERROR
Transfer Direction
Host
Light the red indicator LED
Within 100 ms from the receipt of the LR command, the red indicator
LED lights for approx. 500 ms.
Capture image
Refer to Chapter 10 for details.
Trigger switch control
U1: Auto-off mode
U2: Momentary switching mode
U3: Alternate switching mode
U4: Continuous reading mode 1
U5: Continuous reading mode 2
U6: Auto sensing mode
U7: Auto stand mode
U8: Momentary switching mode (Reverse type)
Save parameters
This command saves settings made with U1 through U7
commands into the EEPROM. Without the PW command, the
scanner will lose settings made with U1 through U7 when it is
turned off.
Request for software version
<Response from the scanner> Ver.n.nn
where n.nn is version number (Ex. Ver.1.00)
Request for the parameter setting version
This command checks the version of the parameter settings made
in the scanner when the scanner is linked with the configuration
software (ScannerSetting_2D).
<Response from the scanner> Ver.n.nn.mm
where n.nn.mm is version number (Ex. Ver.1.00.00)
and mm is parameter setting version.
Request for scan entry mode
In scan master registration for n-point verification, switching the
scanner to the data verification mode, sending a scan entry
control command "E" from the host, and scanning a master code
with the scanner registers the master data which is saved in the
FLASH ROM.
Request for scanner ID (serial number)
<Response from the scanner> ID.nnnnnn
where nnnnnn is a serial number (Ex. ID.000001)
Enable trigger switch
It enables the trigger switch control.
Disable trigger switch
It disables the trigger switch control and switches the scanner
standby.
Scanning failure
When the scanner (which is ready to scan) cannot complete
scanning and switches to standby, it sends the ERROR command
as long as the trigger switch control is set to continuous reading
mode 1 or 2. Whether or not to send this command can be
selected.