5-7-2 Self-recording error rate check

MODE
Playing back the self-recording DVD-RW
Error rate 8.0 × 10
SPEC.
-3
Procedure)
(1) While playing back the self-recording DVD-RW disc, carry out error rate check referring to the table shown below.
ST EP PROCEDURE
C.FG(AUT O)
1
1) Recording for a period of approx. 10 to 30 sec.
2
1) Playing back the part recorded in ST EP 1.
3
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
Note)
(1) For self-recording error rate measurement, use a 8-cm DVD-RW disc manufactured by Maxell.
(2) Select the video recording mode.
(3) In principle, the same conditions are provided in use of any recording mode for error rate measurement. It is however advisable to
select the SP mode.
Note)
* It takes 7 to 20 seconds to indicate an error rate, because it is calculated from large amount of data.
* To measure an error rate again, it is once required to stop the playback.
If the result of the error rate check is NG, perform recheck according to 2-3-1 "Flowchart for Playback Image Error Check" in
Service Hint.

5-7-3 LCD PCB Setting Destination

When mounting the LCD PCB of service part, perform the following adjustment.
ST EP PROCEDURE
1
1) Make the setting shown at right.
2) Add "09" to the current value, and
store the result data.
or less
CS Function MD ADDR DT
0
Fig. 25
MONIT OR
CS Function MD ADDR DT
0
20
ST
RD
MONIT OR
Microcomputer operation
05
ST
0001
01
WR
ª RD
00 Error rate indication.
ª
ª
Error rate indication
Microcomputer operation
0003
--
ADJ
37
DC10 E, DC20 E