Monitoring and Controlling
will enable the operator to be notified of problems with projectors even at
locations away from the projectors.
Network - Mail - Mail Notification
s
a
• Up to a maximum of three notification destinations (addresses) can
be registered, and notification messages can be sent to all three
destinations at once.
• If a projector develops a critical problem and suddenly stops
working, it may not be able to send a message notifying an operator
of the problem.
• Controling is possible if Standby Mode is set to Communication
On, even if the projector is in standby state (when the power is
off).
s Extended - Standby Mode

Reading Error Notification Mail

When the Mail Notification function is set to On and a problem or warning
occurs in the projector, the following email will be sent.
Subject: EPSON Projector
Line 1: The projector name where the problem has occurred
Line 2: The IP address set for the projector where the problem has
occurred.
Line 3 and on: Details of the problem
The details of the problem are listed line by line. The main message
contents are listed below.
• Internal error (Internal Error)
• Fan related error (Fan Error)
• Sensor error (Sensor Error)
• Lamp timer failure (Lamp Failure)
p.78
p.69
• Lamp out (Lamp Error)
• Lamp replacement notification (Replace Lamp)
• Internal temperature error (High Temp Error/overheating)
• High-speed cooling in progress (High Temp Warning)
• Clean Air Filter (Air Filter Notice)
• Low Air Flow (Low Air Flow)
• Low Air Flow Error (Filter Airflow Error)
• Air Flow Sensor Error (Air Flow Sensor Err.)
• No Air Filter (No Air Filter)
• No-signal (No Signal)
No Signal is input to the projector. Check the connection status or check
that the power for the signal source is turned on.
• Exhaust vent shutter Error (Exhaust vent shutter Error)
• Auto Iris Error (Auto Iris Error)
• Power Err. (Ballast) (Power Err. (Ballast))
See the following to deal with problems or warnings.
"Reading the Indicators"
s

Management Using SNMP

By setting SNMP to On in the Configuration menu, notification messages
are sent to the specified computer when a problem or warning occurs. This
will enable the operator to be notified of problems with projectors even at
locations away from the projectors.
Network - Others - SNMP