Unit Setting Addition - Toa NX-100 Installation Setup Manual

Network audio adapters
Hide thumbs Also See for NX-100:
Table of Contents

Advertisement

6. UNIT SETTING ADDITION

Set the broadcast pattern data necessary for the Selection button setting using the NX-100 Setup program
(refer to
Chapter
3). If a unit setting file has already been created, the data is automatically loaded. However,
NX-100 and NX-100S units which are connected through the Internet and cannot be set with the NX-100
Setup program must be added using the Operation program. In order to activate the NX-100 and NX-100S
broadcast patterns set using a browser (refer to
Step 1. Turn on the power to the NX-100 and NX-100S units for which the unit setting is to be added to make
connections possible.
Step 2. Start up the Operation program and select Setting → Unit settings.
The User Authentication screen is then displayed.
Step 3. Enter the system name and the password (the same password used in the setup program), then
press the OK button.
Notes
• Both the system name and the password are case-sensitive.
• The default system name is preset to "NX-100" and the password to "guest" when the unit is
shipped from the factory. To change, refer to
The Unit Settings window is displayed if the system name and the password are correctly entered.
Note
In the initial startup mode, nothing is displayed in the Name, IP Address, Web, TCP and UDP
columns.
Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM)
Chapter
4), add the unit setting using the following procedure:
p. 3-31
or
p.
4-28.
5-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-100s

Table of Contents