Secondary Pcie Riser Cage Option - HP ProLiant DL560 Gen8 User Manual

Hide thumbs Also See for ProLiant DL560 Gen8:
Table of Contents

Advertisement

Remove the PCIe riser cage.
5.
Remove the expansion slot cover.
6.
Install the expansion board.
7.
Connect any required internal or external cables to the expansion board. See the documentation that
8.
ships with the expansion board.
Install the PCIe riser cage
9.
Secure the full-length expansion board retainer to the full-length expansion board.
10.
Install the access panel (on page 20).
11.
Install the server into the rack
12.
Connect each power cord to the server.
13.
Connect each power cord to the power source.
14.
Power up the server (on page 18).
15.

Secondary PCIe riser cage option

WARNING:
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
circuitry remain active until AC power is removed.
CAUTION:
all PCI slots have either an expansion slot cover or an expansion board installed.
IMPORTANT:
To install the component:
Power down the server (on page 18).
1.
Remove all power:
2.
("Install the primary PCIe riser
("Installing the server into the
To reduce the risk of personal injury, electric shock, or damage to the equipment,
To prevent improper cooling and thermal damage, do not operate the server unless
The secondary PCI riser cage option requires both processors.
cage" on page 22).
rack" on page 30).
Hardware options installation 58

Advertisement

Table of Contents
loading

Table of Contents