JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

All wiring should be done by a qualified electrician and shall
be in compliance with all local, city and state building codes.
Before making the electrical connection, make sure that main
power supply is disconnected. The appliance, when installed,
must be electrically grounded in accordance with local codes
or, in the absence of local codes, with the national electrical
code ansi/nfpa 70 (latest edition).
39025-2-0620
CAUTION
A factory installed junction box is located on the lower right hand
side of the fireplace. Wiring must be fed to the junction box and
attached to the receptacle that is provided. Remove the knockout
in the installed junction box to accept wiring into the junction box.
Install a UL listed cable clamp (not supplied) in the knockout hole.
Leave approximately 6" of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached to
the green (neutral) screw.
Install the receptacle into the junction box. Attach cover plate.
Figure 25