When you install an IOM into a slot that previously had an IOM installed, then:
If the IOM being installed is the same type as the previous IOM, the old configuration will be 
applied to the ports on the new IOM.
If the IOM being installed is not the same type as the previous IOM, the default configuration 
will be applied to the ports. 
For more information about the default configuration, see the Enterasys G‐Series CLI Reference 
Guide.

Removing an IOM

To remove an installed IOM:
1.
Disconnect any cabling from the IOM.
2.
Press and hold the POWER OFF button corresponding to the slot from which you are 
removing the IOM for five seconds. The slot's status LED flashes green. Refer to Figure
page 3‐2 for the location of the POWER OFF button.
3.
When the slot's status LED turns amber, it is safe to remove the IOM. Loosen the IOM's two 
captive screws and gently slide the IOM out of the slot using the IOM's handle. For more 
information, refer to "IOM Status LEDs" on page 3‐3
4.
Replace the coverplate to the slot by tightening the coverplate's captive screws. 
The ports associated with the removed IOM continue to show up when displaying port status, 
indicating a configuration exists for these ports, but they are in "detached" state.

Connecting Power to the Switch

You can install a single primary source of power or provide two sources of power for redundancy, 
as described in the following sections. Examples below illustrate connecting two power sources 
and assume two power supply modules have already been installed as described previously in 
"Installing a Power Supply" on page 2‐8.
To connect the G‐Series switch to one or two power sources, proceed as follows: 
1.
Plug an appropriate power cord into each switch AC power receptacle as follows:
Caution: Do not attempt to remove an IOM from the G-Series switch when power is on to the
switch without performing the following procedure.
Precaución: No intente retirar el módulo IOM del switch G Series si éste está encendido. Antes de
hacerlo, debe realizar el siguiente procedimiento.
Caution: Use caution when removing an IOM on which you have optional PoE installed to avoid
damaging the PoE module.
Precaución: Tenga cuidado al retirar un IOM que tenga un módulo PoE instalado, ya que éste
puede dañarse.
Note:
The two power supplies in the
connection to power sources ranging from 100–125 Vac, 12 A or 200–240 Vac, 7A,
Hz.
50/60
G3‐PWR‐POE accepts an IEC320 C19 (20A) power cord. 
G3‐PWR accepts an IEC320 C13 (15A) power cord.
.
G-Series
have automatic voltage sensing that allows
Enterasys G-Series Hardware Installation Guide 2-13

Connecting Power to the Switch

3‐1 on 