Poe (Power Over Ethernet) Support; Fan Management; G3G124 - Enterasys G3G124-24 Hardware Installation Manual

G-series
Hide thumbs Also See for G3G124-24:
Table of Contents

Advertisement

Features

PoE (Power over Ethernet) Support

The G3G124‐24P switch is 802.3af compliant out‐of‐box. The G3G124‐24 and the G3G‐24TX IOM 
can be equipped with user‐installed optional PoE modules to make them 802.3af compliant. For 
more information about installing optional PoE modules, see "Installing an Optional PoE Module 
on the G3G‐24TX IOM" on page
Switch" on page 2‐23.
The G3G switches and IOMs that are 802.3af compliant provide Power over Ethernet cable 
connections from their RJ45 front panel connectors to powered devices (PDs) in the network. 
Power over Ethernet (PoE) refers to the ability to provide 48 Vdc power to a powered device using 
the same Ethernet cabling that provides data. Modern Ethernet implementations employ 
differential signals over twisted pair cables. This requires a minimum of two twisted pairs for a 
single physical link. Both ends of the cable are isolated with transformers blocking any DC or 
common mode voltage on the signal pair. PoE exploits this fact by using two twisted pairs as the 
two conductors to supply a direct current. One pair carries the power supply current and the other 
pair provides a path for the return current. While several proprietary legacy implementations of 
PoE have been deployed by LAN equipment vendors, in 2003 the IEEE published the IEEE 802.3af 
specification, which is part of the 802.3 suite of standards.
The switch is fully compliant with the IEEE 802.3af standard. It supports the standard resistor‐ 
based detection method, as well as AC disconnect capability. The switch is also capable of 
supplying 15.4 watts of power to 96 ports in nonredundant power mode, and 9.4 watts of power to 
96 ports in redundant power mode.
Powered Device Classifications (PDs)
PDs are devices that receive their operating 48 Vdc power through a new or existing Ethernet 
cable from a switch or other device that can provide a PoE‐compliant port connection. This 
enables the PD to operate in a location without local power. For example:
Devices such as PoE‐compliant remote EXIT signs and Personal Data Assistants (PDAs),
Devices that support Voice over IP such as PoE‐compliant digital telephones, 
Devices that support Wireless Application Protocol (WAP) such as security cameras, laptop 
PCs, and many more devices. 

Fan Management

The G3 system supports three groups of independently controllable fans and several firmware 
readable thermal sensors. Fan zones are as follows:
Group 1 (fans 1, 2, and 3) is located in the front left of the switch to cool the Ethernet 
subsystem and optional IOM module slots.
Group 2 (fans 8 and 9) is located in the back left of the switch behind Group 1 to cool the CPU 
subsystem.
Group 3 (fans 4, 5, 6, and 7) is located on either side of the power slots to cool the power 
supplies
Fan speeds are determined by thermal sensors located throughout the G3 system. The firmware 
samples the appropriate thermal sensors at regular intervals, and sets the appropriate fan speeds. 
Fan group 1 drives air flow across the front portion of the chassis, and fan groups 2 and 3 drive air 
flow across the rear portion of the chassis.
1-4 Introduction