11 High Altitude Adjustment

11.1 General

DANGER:
• If installation, adjustment, modification,
operation or maintenance of the heating
system is carried out by an unqualified person,
this may result in danger to life and limb or
property damage. These instructions must be
followed precisely. Contact a qualified service
company, service provider or the gas
company if support or additional information
is required.
11.1.1 Input Rates
,QSXW UDWHV IRU HOHYDWLRQV   IW $6/
Models
GB312-90
GB312-120
GB312-160
GB312-200
GB312-240
GB312-280

11.2 Adjustments



7DEOH 
Input rate
(Mbtu/hr)
328
441
588
733
881
1029
11.3 CO ² adjustment of the burner / adjustment of
the gas valve
&2
 &2 OHYHOV IRU HOHYDWLRQV   IW $6/
å
Models
GB312-90
min-/max- load
GB312-120
min-/max- load
GB312-160
min-/max- load
GB312-200
min-/max- load
GB312-240
min-/max- load
GB312-280
min-/max- load
_ 
7DEOH 
CO ² (Vol. %)
CO (ppm (af) )
9.1 / 9.1
<100
9.1 / 9.1
<100
9.1 / 9.1
<100
9.1 / 9.1
<100
9.1 / 9.1
<100
9.1 / 9.1
<100