Installing Dimms - HP ProLiant ML350 User Manual

G6
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

Do not populate slots C, F, or I.
o
UDIMM
First: A and B
o
Last: D and E
o
Do not populate slots C, F, G, H, or I.
o
After installing the DIMMs, use RBSU to configure the system for Lockstep memory support
lockstep
memory" on page 94).
Multi-processor Lockstep population order
For Lockstep memory mode configurations with multiple processors, populate the DIMM slots for each
processor in the following order:
RDIMM
First: A and B
o
Next: D and E
o
Last: G and H
o
Do not populate slots C, F, or I.
o
UDIMM
First: A and B
o
Last: D and E
o
Do not populate slots C, F, G, H, or I.
o
After installing the DIMMs, use RBSU to configure the system for Lockstep memory support
lockstep
memory" on page 94).

Installing DIMMs

CAUTION:
baffle, drive blanks, and access panel must be installed when the server is powered up.
Power down the server (on page 24).
1.
Do one of the following:
2.
Open or remove the tower bezel, as needed
o
Extend the server from the rack (on page 24).
o
Remove the access panel (on page 26).
3.
Remove the large redundant fan air baffle, if installed
4.
page 27).
Remove the DIMM baffle, if installed
5.
Remove a fan, if necessary.
6.
Open the DIMM slot latches.
7.
To avoid damage to the hard drives, memory, and other system components, the air
("Remove the DIMM
("Open or remove the tower
("Remove the large redundant fan air
baffle" on page 28).
Hardware options installation 51