Server specifications

Environmental specifications

Specification
Temperature range*
Operating
Shipping
Maximum wet bulb temperature
Relative humidity
(noncondensing)**
Operating
Non operating
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.

Mechanical specifications

Specification
Dimension
Height (without tower feet)
Height (with tower feet)
Depth (with tower bezel)
Width
Weight (no drives installed)

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 1200 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Value
10°C to 35°C (50°F to 95°F)
-40°C to 70°C (-40°F to 158°F)
28°C (82.4°F)
10% to 90%
5% to 95%
Value
44.45 cm (17.50 in)
46.70 cm (18.38 in)
60.00 cm (23.60 in)
22.00 cm (8.66 in)
27.22 kg (60.00 lb)
Value
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
10 A at 100 VAC
4.9 A at 200 VAC