No Power - Life Fitness Lifecycle 9500RHR Series Service Manual

Hide thumbs Also See for Lifecycle 9500RHR Series:
Table of Contents

Advertisement

Lifecycle 9500RHR Series Exercise Bikes
TROUBLESHOOTING GUIDE
Symptom: No Power
Symptom
Display Console LEDs do
not illuminate
2
Probable Cause
Pedaling too slowly
Keypad not responding
Insufficient battery voltage
Loose wire connections
Worn or damaged wire
harnesses.
Malfunctioning Display Console
Malfunctioning Alternator
Control Board (ACB)
Malfunctioning Alternator
Corrective Action
Pedal faster than 45 RPM then press the
START button.
Massage keypad with fingertips.
Test the battery voltage. It should be:
5.8 to 6.3 VDC. If necessary, replace the
battery with a fully charged 6V battery.
Disconnect then reconnect connections.
Inspect wire harnesses. Replace worn or
damaged harness.
Test with substitute Display Console. Replace
malfunctioning Display Console.
Test with substitute ACB. Replace
malfunctioning ACB.
Test Alternator output or test with substitute
Alternator. Replace malfunctioning Alternator.
Refer to Alternator Voltage Test.
For Assistance Contact:
Life Fitness Customer Support Services
847.451.0036 or 800.351.3737
Telefacs.: 847.288.3702 or 800.216.8893