2 Site preparation

The HP Integrity BL860c i2 Server Blade does not have cooling or power systems. Cooling and
power is provided by the c-Class enclosure.
IMPORTANT:
the temperature and humidity of the installation facility after removing the shipping materials. A
minimum of one hour per 10°C (18°F) of temperature difference between the shipping facility and
installation facility is required

Server blade dimensions and weight

Table 1 Server blade dimensions and weight for the BL860c i2
Dimensions
Height
Width
Depth
Weight
Table 2 Blade Link dimensions and weight
Blade Link type
SBL1 (BL860 i2)
SBL2 (BL870 i2)
SBL4 (BL890 i2)

Enclosure information

All three blade configurations are supported in c7000 and c3000 Enclosures.
For more enclosure information see:
http://h71028.www7.hp.com/enterprise/cache/316735-0-0-0- 1

Enclosure environmental specifications

NOTE:
This information is for both c3000 and c7000 Enclosures.
Specification
Temperature range
Operating
Non-operating
Wet bulb temperature
Operating
Non-operating
Relative humidity (noncondensing)
10
Site preparation
To avoid hardware damage, allow the thermal mass of the product to equalize to
value
36.63 cm (14.42 in.)
5.14 cm (2.025 in.)
48.51 cm (19.1 in.)
Unloaded: 8.6 kg (19 lb)
Fully loaded: 1 1.3 kg (25 lb)
Height
44 mm (1.73 in)
44 mm (1.73 in)
44 mm (1.73 in)
1
2
Width
51 mm (2 in)
106 mm (4.17 in)
212 mm (8.34 in)
21.html.
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
28ºC (82.4ºF)
38.7ºC (101.7ºF)
Weight
.5 lb (.22 kg)
1 lb (.45 kg)
2 lb (.90 kg)