Blade Link For Bl860C I2 Configurations - HP Integrity BL860c i2 User's & Service Manual

Server blade
Hide thumbs Also See for Integrity BL860c i2:
Table of Contents

Advertisement

12. Log into iLO 3 on the Monarch blade. For more information, see the HP Integrity iLO3
Operations Guide.
13. In iLO 3, go to the Command Menu and execute xd -r to reboot all of the iLO 3s in the
conjoined set.
14. Still in the iLO 3 Command Menu, power on the Monarch blade with the PC -on -nc
command. Powering on the Monarch blade will power the entire conjoined system on.
15. Boot the Monarch blade. Booting the Monarch blade boots the entire conjoined system.

Blade Link for BL860c i2 configurations

IMPORTANT:
circumstances:
The Blade Link is faulty.
You will be using the blade in a BL870c / BL890c i2 configuration.
CAUTION:
proceeding.
1.
Power off the server blade and remove it from the enclosure
servicing").
2.
Place the blade on a flat, level, antistatic surface on its side, with the access panel facing up.
3.
Squeeze the blue button on the side of the bezel.
4.
While holding in the release button, pull the Blade Link off the blade while applying counter
pressure down on the blade to keep the blade from moving.
5.
Place a plastic protector over the connector on the back of the Blade Link and place it in an
antistatic bag.
NOTE:
IMPORTANT:
ID values out of the faulty Blade Link and place it inside the label carrier door of the new Blade
Link.
To replace the component, reverse the removal procedure.
1 12
Removing and replacing components
Only remove a Blade Link from a BL860c i2 Server Blade in the following
To prevent damage to the Blade Link, make sure that the activity light is off before
Plastic protectors are only provided with replacement Blade Links.
If you are replacing a faulty Blade Link, take the label carrier card with the system
("Preparing the server blade for