High-capacity feeder input tray service check

Note: Voltage measurements in the high-capacity feeder input tray service checks must be made with the high-
capacity feeder attached to the printer to obtain accurate results.
Service tip: Be sure the paper size switch is set to the correct paper size setting and the rear paper guides are in
the correct locations for the size of paper installed in the high-capacity feeder tray.
Service tip: Check the other paper sources to be sure they are operating correctly.
The printer indicates a dead machine condition when the high-capacity input tray is
installed
FRU
1
AC line cord
AC jumper (HCIT to printer)
AC input and output
receptacles
AC wiring harness
The MFP does not recognize that the high-capacity input tray is installed
FRU
1
high-capacity feeder
autoconnect mechanical
check
2
Printer or option mounted
above
3
LVPS
Option system board
Action
If the printer works normally using the AC line cord from the AC wall
outlet and does not work when using the AC jumper from the HCIT,
check the AC jumper cord. If defective, replace the cord. If not
defective, check the AC input and output receptacles and wiring
harness in the HCIT. Repair or replace the receptacles or AC wiring
harness as required.
Note: Make sure the ground wire is installed correctly from the AC
wiring harness to the frame of the HCIT and the nut and lock washer
are tightened.
Action
Check the high-capacity feeder input tray to make sure it is mounted
correctly and is not pushed down into the frame assembly or
damaged. Be sure the high-capacity feeder input tray autoconnect is
properly connected to the high-capacity feeder tray option board
assembly.
Check the option or printer autoconnect for signs of damage. Repair
the high-capacity option autoconnect as necessary.
Check the voltages at J11-2 and J11-4. The voltage measures
+24 V dc, If the voltage is correct, replace the high-capacity system
board assembly. If the voltage is incorrect, check the continuity of the
AC input cable to the LVPS. If correct, replace the LVPS assembly. If
incorrect, replace the AC cable to the input of the LVPS.