Chapter 5 - Trunks and Extensions
Installation
1. Set the Dip switch (SW2-1) of the PRI/23 card OFF (extension).
2. Set the Dip switch (SW2-2) of the PRI/23 card as shown in Table 5-33.
Table 5-33. Switch Setting for SW2-2 on PRI/23 Card
Switch No.
Function
SW2-1
ON
OFF
SW2-2
ON
OFF
3. Set SW1 on the PRI/23 card according to the following table.
Table 5-34. Switch Setting for SW1 on PRI/23 Card
Switch No.
4. Insert the PRI/23 card into the specified flexible slot.
5. Connect the 8-conductor modular jack to the S-point ISDN primary rate
6. Pass the S-point ISDN wires with 8-conductor modular jack through the wiring
5-46
Set to "Exchange line" for T-point.
Set to "extension" for S-point.
Set to "Other mode." Can be used with 1 to 23B+D/24B channels.
Set to "8-channel mode." Can be used with 1 to 8B + D channels.
These switch settings correspond to the distance between the DBS 576
and the ISDN terminal. To turn a switch on, set it to the "up" position.
Distance from the DBS 576 to the ISDN terminal
0 to 150 ft.
SW1-1
ON
SW1-2
OFF
SW1-3
OFF
SW1-4
OFF
SW1-5
OFF
SW1-6
OFF
SW1-7
OFF
SW1-8
interface wires from the ISDN terminal equipment.
aperture in the cabinet and connect it to the modular connector on the
PRI/23 card.
DBS 576 (USA), issued 6/2/98
Section 300-Installation
150 to 450 ft.
450 to 655 ft.
OFF
ON
OFF
ON
OFF
ON
OFF
Not used
OFF
OFF
ON
OFF
ON
OFF
ON
576-13-300