Straight end to the back
Cut end to the front
September 1, 2008
Cumberland Gap Wood Stove
BAFFLE DIVERTER
REQUIRED ON ALL

HORIZONTAL INSTALLATIONS

Slanted corner
1. Open both doors.
2. Hold the diverter in a vertical position with the
straight edge going in first and then rotate it to
the inside of the firebox as you slide the bent
diverter over the ceramic blanket .
3. Place in position as shown in diagram below.
The front edge of the diverter will rest on the
front edge of the manifold chamber in a flush
position. The back edge will butt up against the
back slanted corner.
4. Repeat for other side.
Ceramic Blanket
Manifold
chamber
7006-188E