INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
TREKKER INSERT PELLET
APPLIANCE
MODEL(S):
TREKKERI-MBK
TREKKERI-CSB
TREKKERI-PMH
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, fire officials or authorities
having jurisdiction about restrictions, installation
inspection, and permits.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal
injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void your
warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down. Hot glass will
cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
To obtain a French translation of this manual, please contact
your dealer or visit
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez
7082-153D
WARNING
WARNING
CAUTION
NOTE
www.quadrafire.com
www.quadrafire.com
September 27, 2018

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire TREKKERI-MBK TREKKERI-CSB TREKKERI-PMH

  • Page 1 Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is not followed exactly, a fire could result TREKKER INSERT PELLET causing property damage, personal injury, or death.
  • Page 2: Table Of Contents

    F. Equivalent Feet of Pipe ..... .16 G. Pipe Selection Chart ..... . .16 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7082-153D...
  • Page 3: Important Safety Information

    E1509-12, ULC S628-93, (UM) 84-HUD and ULC/ORD-C-1482. This manual describes the installation of the Quadra-Fire, Trekker Insert pellet appliance. This appliance meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 12,682 to 39,428 Btu/hr.
  • Page 4: Glass Specifications

    TREKKER INSERT C. Glass Specifications WARNING This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please Fire Risk contact your dealer for replacement glass. Hearth & Home Technologies disclaims any D. Electrical Rating responsibility for, and the warranty will be voided 115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps by, the following actions: E.
  • Page 5: Getting Started

    TREKKER INSERT Install Guide Getting Started A. Design, Installation & Location Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: Considerations • Windows 1. Appliance Location • Air Intakes NOTICE: Check building codes prior to installation. •...
  • Page 6: Tools And Supplies Needed

    TREKKER INSERT C. Inspect Appliance and Components WARNING • Open the appliance and remove all the parts and articles packed inside the Component Pack. Inspect all Risk of Fire! the parts and glass for shipping damage. • Damaged parts could impair safe operation. •...
  • Page 7: Install Checklist

    TREKKER INSERT D. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________ Date Installed: _______________________________________________________________________ Lot/Address: ________________________________________________________________...
  • Page 8: Dimensions And Clearances

    TREKKER INSERT Dimensions and Clearances A. Appliance Dimensions 32 in [814mm] 32 in [814mm] 23-7/8 in [606mm] 23-7/8 in [606mm] 16-1/4 in 16-3/8 in [413mm] [415mm] 15 in 15-1/8 in 14-1/8 in 14-1/4 in [382mm] [384mm] [359mm] [361mm] 13 in 13-1/8 in [330mm] [333 mm]...
  • Page 9: Clearance To Combustibles, Us & Can

    TREKKER INSERT B. Clearance to Combustibles, US & CAN Built-in Appliance - Rear Vent 26-7/8 in.** (683 mm) 36 in. (914 mm) 19-3/8 in.* *If interior of chase will be drywalled, add the (572 mm) thickness to this measurement. **From finished floor protection. The size of your floor protector choice must be added to this dimension.
  • Page 10: Minimum Opening For Masonry & Zc Fireplaces

    TREKKER INSERT Built-In Vertical C. Minimum Opening for Masonry & ZC Fireplaces TOP TRIM 18-5/16 in 24-5/16 in (465mm) (618mm) 29-3/4 in (1010mm) Figure 10.3 Minimum Opening Inches Millimeters Dimensions HEARTH Height 24-3/8 (406mm) EXTENSION Front Width (Steel Panel 32-1/4 Figure 10.1 Set) Front Width (Cast Panel...
  • Page 11: Installation Into A Factory-Built Fireplace

    TREKKER INSERT The following is only one example as there are many F. Installation into a Factory-Built Fireplace different models of factory-built fireplaces. The following modifications are permissible: Removal of damper or locked in open position NOTE: This example is for reference only. Any Removal of smoke shelf or baffle modifications must not compromise the structural Removal of ember catches...
  • Page 12: Installation Into A Masonry Fireplace

    TREKKER INSERT G. Installation into a Masonry Fireplace H. Prefabricated Metal Chimney All modifications that can be made to a Factory Built The chimney can be new or existing, masonry or Fireplace can be made to a Masonry Fireplace. prefabricated and must meet the following minimum requirements: In addition DO NOT remove any brick or mortar from the Must be minimum 6 inch (152mm) inside diameter...
  • Page 13: Vent Information

    TREKKER INSERT Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Termination Cap Air Supply Inlet Restricted Area Gas Meter Figure 13.1 All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. Above Finish Grade (the grade surface must Above grass, top of plants, wood or any other 12 in.
  • Page 14: Avoiding Smoke And Odors

    TREKKER INSERT B. Avoiding Smoke and Odors Vent Configurations When installing a pellet appliance with a horizontal vent Negative Pressure, Shut-Down and Electrical Power configuration the frequency of power outages should be Failure considered: • Power outages during operation will cause the To reduce the probability of back-drafting or burn-back appliance to immediately turn off and may create in the pellet appliance during power failure or shut down...
  • Page 15: Negative Pressure

    • Range hoods Adapter, use Listed double wall flue connector. A • Combustion air requirements for furnaces, water Quadra-Fire Outside Air Kit (OAK-3) must be used with appliances and other combustion appliances manufactured home installations. • Clothes dryers 3. Residential: The 3 inch (76mm) vertical Top Vent •...
  • Page 16: Equivalent Feet Of Pipe

    TREKKER INSERT F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent Vent surfaces get HOT, can cause burns size (Figure 16.1). if touched. Non-combustible shielding or guards may be required.
  • Page 17: Venting Systems

    TREKKER INSERT Venting Systems A. Full Reline wit Outside Air - Horizontal WARNING Fire Risk. CAUTION Inspection of Chimney: • Masonry chimney must be in good Never draw outside combustion air from: condition. • Wall, floor or ceiling cavity • Meets minimum standard of NFPA 211 •...
  • Page 18: Full Reline With Outside Air - Vertical

    TREKKER INSERT B. Full Reline with Outside Air - Vertical NOTE: Check clearances carefully for this type of NOTE: In Canada only a full reline is allowed per ULC installation to ensure adequate room for outside S628, ORD ULC C1482-M1990. air venting.
  • Page 19: Appliance Set-Up

    TREKKER INSERT Appliance Set-Up A. Leveling System The leveling bolts are located on the sides of the appliance, front and rear. To access the bolts, remove the front access panels. Reach in and turn the bolt to the desired height to level the appliance (Figure 19.1).
  • Page 20: Removal Of Cast Sides

    TREKKER INSERT E. Surround & Cast Trim Set Included in Surround Kit: (2) side panels, left and right; 3 inch (1) panel top; (1) fastener package. high Set Attach Trim to Insert from Included in Cast Trim Kit: (2) cast trim legs, left and right; inside Insert.
  • Page 21: Surround & Basic Trim Set

    TREKKER INSERT F. Surround & Basic Trim Set G. Optional Log Set Instructions Included in Surround & Trim Kit: (2) corner brackets and 2 PIECE LOG SET INSTALLATION set screws; (1) trim set, 3 piece; (2) side panels; (1) top 1.
  • Page 22: Installation Of Bluetooth Key

    TREKKER INSERT H. Installation of Bluetooth Key Install battery (Figure 22.4) Plug the Bluetooth key into the appliance (Figure 22.1). Figure 22.3 NOTE: See user interface manual on how to operate the user interface. Figure 22.1 J. Location & Mounting of User Interface Make sure you have a reliable bluetooth connection I.
  • Page 23: Mobile Home Installation

    TREKKER INSERT Mobile Home Installation You must use a Quadra-Fire Outside Air Kit for CAUTION installation in a mobile home. 1. An outside air inlet must be provided for the THE STRUCTURAL INTEGRITY OF THE MOBILE combustion air and must remain clear of leaves, debris, HOME FLOOR, WALL AND CEILING/ROOF MUST BE ice and/or snow.
  • Page 24: Reference Materials

    TREKKER INSERT Reference Materials A. Service & Maintenance Log Date of Service Performed By Description of Service 7082-153D September 27, 2018...
  • Page 25 TREKKER INSERT Date of Service Performed By Description of Service September 27, 2018 7082-153D...
  • Page 26 TREKKER INSERT Date of Service Performed By Description of Service 7082-153D September 27, 2018...
  • Page 27: Accessory List

    TREKKER INSERT B. Accessory List TREKKER INSERT Service Parts Beginning Manufacturing Date: June 2018 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 28 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents