Junction Box Installation; Wall Switch Installation For Fan (Optional) - Heatilator Gas Fireplace GDCL4136I Owner's Manual

Hearth and home technologies gas fireplace owner's manual installation and operation
Hide thumbs Also See for Gas Fireplace GDCL4136I:
Table of Contents

Advertisement

THERMOCOUPLE
VALVE
Figure 12.4 Standing Pilot Ignition Wiring Diagram
F. Junction Box Installation
The junction box must be wired from the INSIDE of the
appliance:
• Determine which side of the appliance the junction box
is located on.
• Pull the electrical wires from outside the appliance through
the knockout making sure to use a Romex connector to
fasten the electrical wires to the unit.
• Pull enough wire into the valve compartment to easily reach
the junction box location.
• Remove the screw attaching the junction box to the junction
box bracket and set it aside.
• Route the wire through the knockout in the junction box
bracket.
• Wire the junction box and reattach it to the bracket by
inserting the tab in the slot and attaching with screw
previously removed. Ensure that a Romex connector is
used to attach the electrical wires to the junction box.
G. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 12.6):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box to
the appliance using a minimum of 14-3 with ground wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
54
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. F • 11/08
PILOT
THERMOPILE
RED
PIEZO
ROMEX CONNECTORS
Figure 12.5 Junction Box Detail
MINIMUM 14-3 AWG
WITH GROUND
JUNCTION BOX
RED
Figure 12.6 Junction Box Wired to Wall Switch or BC10
THERMOSTAT
WIRE ASSEMBLY
NOTICE: DO NOT wire
110 VAC to wall switch.
SWITCH
RED
BLACK
BLACK
WHITE
WHITE
GREEN
GREEN
POWER
SWITCH BOX
SUPPLY
WIRES
KNOCKOUT