Heatilator GDST5244I Owner's Manual
Heatilator GDST5244I Owner's Manual

Heatilator GDST5244I Owner's Manual

Direct vent gas appliance
Hide thumbs Also See for GDST5244I:
Table of Contents

Advertisement

Model(s):
GDST5244I
GDST5244IL
Direct Vent Gas Appliance
• Important operating and
maintenance instructions
included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
This appliance may be installed as an OEM installation
in manufactured home (USA only) or mobile home and
must be installed in accordance with the manufacturer's
instructions and the manufactured home construction and
safety standard, Title 24 CFR, Part 3280 or Standard for
Installation in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas
indicated on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand and follow
these instructions for safe
installation and operation.
• CAREFULLY SUPERVISE children in same room as
• A l e r t c h i l d r e n a n d a d u l t s t o h a z a r d s o f h i g h
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other combustibles
This appliance has been supplied with an integral
barrier to prevent direct contact with the fixed glass
panel. Do NOT operate the appliance with the barrier
removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must
be performed by a licensed plumber or gas fitter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
appliance.
temperatures.
away.
Installation and service of this appliance should be performed
by qualified personnel. Hearth & Home Technologies
suggests NFI certified or factory-trained professionals, or
technicians supervised by an NFI certified professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator GDST5244I

  • Page 1 NFI certified or factory-trained professionals, or This appliance is only for use with the type(s) of gas technicians supervised by an NFI certified professional. indicated on the rating plate. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 2: Congratulations

    DO NOT REMOVE OR COVER THIS LABEL. VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL. FOYER À GAZ À ÉVACUATION - NE DOIT PAS ÊTRE UTILISÉ AVEC UN COMBUSTIBLE SOLIDE. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 3: Table Of Contents

    A. Select Appliance Location Wall Switch Installation for Fan (Optional) B. Construct the Appliance Chase C. Clearances D. Mantel and Wall Projections 6 Termination Locations A. Vent Termination Minimum Clearances Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 4 16 Troubleshooting A. Intellifire Ignition System 17 Reference Materials A. Appliance Dimension Diagram B. Vent Components Diagrams C. Service Parts D. Optional Components E. Contact Information  = Contains updated information. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 5: Warranty

    • Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. 4021-645A 09-01-08 Page 1 of 2 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 6 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide neces- sary parts or components, contact the nearest authorized HHT dealer or supplier. 4021-645A 09-01-08 Page 2 of 2 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 7: Listing And Code Approvals

    Please contact your dealer or distributor to order. compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 8: Requirements For The Commonwealth Of

    See Gas Connection section for additional Common- read, in print size no less than one-half (1/2) in. in size, wealth of Massachusetts requirements. “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 9: User Guide

    Decorative Doors (not shown) Section 2.E. Grate (not shown) Section 3.B. Fixed Glass Assembly Section 2.F. Fan Kits Section 2.C Clear Space Section 2.D. Hearth (not required) Figure 2.1 General Parts Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 10: Fan Kit (Optional)

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 11: Lighting Instructions (Ipi)

    * For U.S. only! NATURAL GAS Due to high surface temperatures, keep children, clothing and furniture away. Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance. 33631D Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 12: After Fireplace Is Lit

    In an IntelliFire ignition system (IPI), the pilot flame should turn off when appliance is turned off. flame burn continually? Some optional control systems available with IPI models may allow pilot flame to remain lit. In a standing pilot system the pilot will always stay on. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 13: Maintenance And Service

    Verify weather stripping, sealing and flashing remains - Heavy deposits: Use commercial fireplace glass cleaner intact. (consult with your dealer) • Inspect draft shield to verify it is not damaged or missing. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 14: Maintenance Tasks-Qualified Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 15: Installer Guide

    Framing/Header in Ceiling Joists (SECTION 5) (SECTION 8) Optional Wall Switch Mantel & Mantel Leg (SECTION 14) Surround Hearth Extension (not required) Gas Line (SECTION 12) Figure 4.1 Typical System Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 16: Design And Installation Considerations

    Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 17: Framing And Clearances

    The chase should not break the outside building envelope in any manner. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 18: Clearances

    Width Height Depth for Venting 53-1/8 44-1/2 10 (DVP) - 9 (SLP) 1349 1127 254 (DVP) - 229 (SLP) 36 in. (914 mm) 0 in. Figure 5.2 Clearances to Combustibles Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 19: Mantel And Wall Projections

    Mantel Leg or Wall Projections (Acceptable on both 7-3/4 sides of opening) 6-1/4 4-5/8 Measured from top of fireplace opening (in inches) Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 20: Termination Locations

    Over 18/12 to 20/12 Over 10/12 to 11/12 3.25 Over 20/12 to 21/12 * 3 ft. minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 21 Figure 6.3 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 22: Vent Information And Diagrams

    Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 6.4). • Vertical terminations are measured to bottom of termination cap. • Horizontal pipe installed level with no rise. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 23: Vent Diagrams

    12 ft (3.66 m) min. 60 ft (18.29 m) max. 60 ft (18.29 m) max. min. max. max. 0.0 2 in. 81 mm 0.46 5.49 0.61 7.62 7.62 7.62 Figure 7.3 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 24 (1.22 m) 25 ft max. (7.62 m) Figure 7.4 min. max. max. H max. Two Elbows 0.46 5.49 5.49 0.61 7.62 7.62 7.62 7.62 7.62 Installed Vertically Installed Horizontally Figure 7.5 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 25 1. Top Vent - Horizontal Termination - (continued) min. max. max. Three Elbows 0.0 7.2 5.79 Installed Vertically Figure 7.6 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 26 See Figures 7.7a and 7.7b. Two Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) Figure 7.8 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 27 2. Top Vent - Vertical Termination - (continued) Three Elbows Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 7.9 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 28: Vent Clearances And Framing

    Sides: 1 in. (25 mm) Framing should be constructed of 2 X 4 lumber or heavier. * Measured to Figure 8.1 Horizontal Venting Clearances To Combustible Materi- center of pipe. Figure 8.2 Wall Penetration Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 29: Install The Ceiling Firestop

    Install attic insula- tion shields before or after installation of vent system. 3 fasteners per side Ceiling firestop Ceiling firestop installed below ceiling. installed above ceiling. Figure 8.4 Installing the Attic Shield Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 30: Install Attic Insulation Shield 0

    Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 31: Appliance Preparation

    Secure the appliance to the framing by using nails or screws through the nailing tabs. • Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 32: Install Vent Pipe

    Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 33: Assemble Vent Sections (Slp Only)

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 34: Secure The Vent Sections 4

    Figure 10.10 Rotate Seams for Disassembly Figure 10.8 Securing Vertical Pipe Sections Figure 10.11 Align and Disassemble Vent Sections Figure 10.9 Securing Horizontal Pipe Sections Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 35: Install Decorative Ceiling Components (Slp Only) 5

    (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 10.15. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 36: Assemble And Install Storm Collar 6

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 10.15. Pipe Caulk Figure 10.17 Assembling the Storm Collar Around the Pipe Flashing Figure 10.15 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 37: Install Vertical Termination Cap 7

    Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.19. Figure 10.19 Wall Thimble Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 38: Install Horizontal Termination Cap 8

    SLP-TRAP2 can adjust 4 in. (5 1/4 to 9 1/4) DVP-HPC1 can adjust 2 1/8 in. (4 1/4 to 6 3/8) DVP-HPC2 can adjust 4 1/8 in. (6 3/8 to 10 1/2) Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 39: Shrouds

    19 x 19 Min. 48 x 48 Top Dim. Min. Top Dims. 16 x 16 406 x 406 Min. Base Dim. Min. Base Dim. Figure 11.1 Open Top Shroud Dimensions Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 40 20 x 20 508 x 508 Min. Height Minimum Height Minimum Opening Min. Opening Width Height Min. Opening Width Minimum Base Dimension Min. Opening Height Figure 11.2 Roofed Style Shroud Dimensions Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 41: Gas Information

    1/2 in. (13 consult local gas utility. mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 42: Electrical Information

    Pack Optional Remote Sensor Control Pilot Assembly Junction GRN* Adapter * GRN wire only for use with optional wall switch WSK-MLT Valve Figure 13.1 Intellifire Pilot Ignition (IPI) Wiring Diagram Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 43: Junction Box Installation

    (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Figure 13.3 Junction Box Wired to Wall Switch or BC10 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 44: Finishing

    0 in. min. to perpendicular wall 4-5/8 in. (117 mm) min. from fireplace opening to perpendicular wall Figure 14.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 45: Appliance Setup

    Figure 15.3 Middle Log (#6) Placed on Pins P1 & P2 Top - Middle, Back Log Top - Right, Back Log Top - Right, Front Log Top - Left, Front Log Figure 15.1 Log Identification Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 46 Figure 15.5 Place Top - Middle, Back Log (#8) Placed on Pin P4 and Lays on Notch of Log 6 Figure 15.9 Completed Log Set Figure 15.6 Place Top - Right, Back Log (#9) Placed on Pins P5 & P6 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 47: Place The Rockwool

    Replacing Fixed Glass Assembly • Replace the glass panel assembly on the appliance. • Pull out and latch the six latches into the groove on the glass door frame. Figure 15.12 Air Shutter Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 48: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/ Verify battery voltage is at least 2.7 volts. Replace batteries if voltage Pilot solenoid ohms readings. is below 2.7. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 49 “I” from module. Place ON/OFF rocker switch or wall switch in ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fine. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 50: Reference Materials

    1 in. 2-7/8 in. (25 mm) (73 mm) 5 in. (127 mm) 4-7/8 in. Gas Knockouts 4-7/8 in. (124 mm) (124 mm) 5 in. (127 mm) Figure 17.1 Appliance Dimensions Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 51: Vent Components Diagrams

    (254 mm) 8 in. (203 mm) 14 in. (356 mm) 12 in. (305 mm) 5 in. (127 mm) DVP-HVS DVP-WS Vent Support Wall Shield Firestop Figure 17.2 DVP Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 52 DVP-TRAPFL Flashing 13-7/8 in. 9-1/2 in. (352 mm) (241 mm) 26 in. (660 mm) 14 in. (356 mm) DVP-HSM-B DRC-RADIUS Extended Heat Shield Cap Shield Figure 17.3 DVP Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 53 DVP-FBHT 7-1/8 in. 12-1/8 in. Fire Brick Termination Cap (181 mm) (314 mm) 8-3/4 in. (222 mm) 1-5/8 in. (41 mm) DVP-HPC High Performance Cap Figure 17.4 DVP Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 54 12 in. 5-3/8 in. 9-3/8 in. Trap2 Effective (305 mm) 137 mm 238 mm Length DVP-TRAP Horizontal Termination Cap DVP-TRAP1 DVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 Figure 17.5 DVP Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 55 8-3/8 in. 5-3/4 to 8-3/8 in. 140 mm 213 mm 146 to 213 mm 3° 87° 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-ZC-SS Figure 17.6 DVP Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 56 (660 mm) SLP-HVS DVP-HSM-B Horizontal Pipe Extended Heat Shield Support SLP-FS SLP-WS SLP-DCF-BK SLP-WT-BK Ceiling Firestop Wall Shield Firestop Decorative Ceiling Wall Thimble-Black Firestop-Black Figure 17.7 SLP Series Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 57 5-3/4 to 8-3/8 in. 140 mm 213 mm 146 to 213 mm 3° 87° 10-1/2 in. 267 mm 10-7/8 in. 276 mm SLP-TRAP2 Horizontal SLP-HRC-ZC-SS Termination Cap Figure 17.8 SLP Series Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 58 79 mm 121 mm 12 in. 5 1/4 in. 9 1/4 in. Trap2 Effective (305 mm) 133 mm 235 mm Length SLP-TRAP Horizontal Termination Cap Figure 17.9 SLP Series Vent Components Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 59: Service Parts

    C. Service Parts  Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 60 C. Service Parts (continued) Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 61: Optional Components

    Catalog # LDS LDS46 1219 1829 LDSCP-M Shroud Leg Multipack (not shown) LDS-BV Decorative Shroud Catalog # 12.5 15.5 LDS-BV See your Heatilator dealer for a complete listing of optional components. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 62 This page intentionally left blank. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 63 This page intentionally left blank. Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...
  • Page 64: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2008 Heatilator • GDST5244I • 4045-127 • Rev Z • 08/09...