Heatilator GDFL4136I Owner's Manual

Heatilator GDFL4136I Owner's Manual

Installation and operation
Hide thumbs Also See for GDFL4136I:
Table of Contents

Advertisement

Para obtener un ejemplar en Español de este
Manual del propietario, visite www.heatnglo.com.
Models:
GDST4336I
GDFL4136I
GDCR4136I
GDCL4136I
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
HOT GLASS WILL
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator GDFL4136I

  • Page 1 See Table of Contents for location of additional Commonwealth appliance is not convertible for use with other of Massachusetts requirements. gases, unless a certifi ed kit is used. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 2: Congratulations

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 3: Table Of Contents

    D. Mantel and Wall Projections ..... . . 21 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 4 D. Contact Information ......84  = Contains updated information. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 9: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. • Never leave children alone near a hot fi replace, whether operating or cooling down. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 10: Fan Kit (Optional)

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 11: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 12: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Remove all foreign objects. • Verify unobstructed air circulation. Burner Ignition and Operation Figure 3.1 IPI Pilot Flame Patterns Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 15: Installer Guide

    HEARTH EXTENSION Note: Dual venting configurations ARE NOT allowed. Appliance MUST be vented EITHER vertically OR horizontally. SURROUND MANTEL AND MANTEL LEG (SECTION 5.D) Figure 4.1 Typical System Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 16: Design And Installation Considerations

    Installation and service of this appliance should be performed by qualifi ed personnel. Hearth & Home  Technologies recommends HHT Factory Trained or NFI certified professionals. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 17: Inspect Appliance And Components

    Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Figure 4.3 Do Not Remove Standoff Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 18: Framing And Clearances

    914 mm 36 in. 914 mm 36 in. 914 mm 36 in. 914 mm GDST4336I GDCR4136I 36 in. 36 in. 914 mm 914 mm Figure 5.1 Appliance Locations Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 19: Constructing The Appliance Chase

    Opening Opening (Height) (Width) (Width) (Width) (Depth) Inches 8-5/8 38-1/8 34-1/8 Millimeters 1092 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.2 Clearances to Combustibles Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 20 Opening Opening (Height) (Width) (Width) (Width) (Depth) Inches 8-5/8 38-1/8 34-1/8 Millimeters 1016 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.4 Clearances to Combustibles Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 21: Mantel And Wall Projections

    MEASUREMENT FROM FIREPLACE OPENING TO BOTTOM OF Figure 5.8 Minimum Vertical and Maximum Horizontal APPLIANCE= 33-1/2 IN. Dimensions of Non-Combustibles Figure 5.6 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 22 (Acceptable on both sides of opening) SHEETROCK 3.5 in. AIR SPACE REQUIRED Figure 5.10 Non-Combustible Zone (GDFL4136I, GDST4336I) SHEETROCK 3.5 in. AIR SPACE REQUIRED Figure 5.11 Non-Combustible Zone (GDCR4136I and GDCL4136I) Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 23: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 24 2 sides beneath the fl oor. venting system does not meet these requirements. • Vinyl protection kits are suggested for use with vinyl siding. Figure 6.3 Minimum Clearances for Termination Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 25: Vent Information And Diagrams

    DVP6 Effective Height/Length DVP12 DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 26: Vent Diagrams

    Installation requirements to replace the fi rst 90° elbow with two 45° elbows: elbow on rear vent appliances. 4 ft min. (1.22 m) 1/4 in. max. (6 mm) 16 ft max. (4.87 m) Figure 7.3 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 27 18 ft. 5.5 m 5 ft. 1.5 m 20 ft 6.1 m = 50 ft. (15.2 m) Maximum = 20 ft. (6.1 m) Maximum INSTALLED HORIZONTALLY Figure 7.5 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 28 4.9 m 3 ft. 914 mm 14 ft.* 4.3 m 6 ft 1.8 m = 20 ft. (6.1 m) Maximum = 50 ft. (15.2 m) Maximum Figure 7.6 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 29 The exhaust restrictor can be located in the panel after exhaust appliance manual bag. restrictor installation. Figure 7.8 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 30 MUST subtract one number from the table above. Example: Top vent 40 ft vertical with DVP pipe = 5-4 Top vent 40 ft vertical with SLP pipe = 4-3 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 31 18 ft. 5.5 m = 18 ft (5.5 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) INSTALLED HORIZONTALLY Figure 7.12 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 32 = 18 in. (406 mm) Maximum No Elbow Figure 7.13 One 45° Elbow DO NOT use a 45º elbow in corner installations. Use two 90º elbow instead. Figure 7.14 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 33 12 ft. 3.7 m 15 ft. 4.6 m = 40 ft (12.2 m) Maximum = 3 ft (94 mm) Maximum = 15 ft (4.6 m) Maximum Figure 7.16 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 34 12 ft. 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m = 40 ft (12.2 m) Maximum = 8 ft (2.4 m) Maximum INSTALLED HORIZONTALLY Figure 7.18 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 35 8 ft. 2.4 m *No specifi c restrictions on this value EXCEPT cannot exceed 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED Figure 7.20 HORIZONTALLY Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 36: Vent Clearances And Framing

    Top: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Figure 8.1 Horizontal Venting Clearances To Combustible Materials Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 37: Wall Penetration Framing

    (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 8.5 Wall Penetration Note: When terminating horizontally off the top of the unit using SLP pipe, a 10 in. x 10 in. framing hole is required. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 38: Vertical Penetration Framing

    Figure 8.6 INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.7 Installing the Attic Shield Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 39: Appliance Preparation

    Secure the vent gasket to the appliance with two Remove screws to access vent. self-tapping screws found in the manual bag. Note: The vent gasket can found in the manual bag. Proceed to Section 9. C. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 40: Rear Vent

    Secure the vent gasket to the appliance with two self-tapping screws found in the manual bag. Note: The vent gasket can found in the manual bag. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 41: Securing And Leveling The Appliance

    4. Level the appliance from side to side and front to back. It CANNOT be changed at a later time. is acceptable to use wood shims under the appliance. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 42 Figure 9.13 Do Not Remove Refractory WARNING! Risk of Fire! DO NOT remove standoff. Appliance could overheat! DO NOT REMOVE STANDOFF DO NOT REMOVE STANDOFF Figure 9.14 Do Not Remove Standoff Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 43: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 44: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not Figure 10.5 Adding Venting Components required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 45: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 46: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. WARNING! Risk of Fire! Clean out ALL materials from Figure 10.13 inside the support box and complete the vertical vent run and termination. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 47: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 48: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.18. Figure 10.18 Wall Thimble Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 49: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 50: Gas Information

    fl exible gas connector are connected to the 1/2 inch (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 51: Electrical Information

    Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 52 3 VAC WHITE GROUND TO FIREPLACE PLUG IN CHASSIS WIRES BATTERY PACK (TO BROWN) REMOTE PLUG IN VALVE Figure 12.2 Intellifi re Ignition Wiring Diagram with Remote Receiver Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 53: Junction Box Installation

    (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch Figure 12.4 Junction Box Wired to Wall Switch or BC10 connector (1/4 in. male) as shown. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 54: Finishing

    Figure 13.2 Folding Top Flap Step 3. Crease fl aps on left and right sides of splatter guard Figure 13.5 Top slot using the scored line as the guide. See Figure 13.3. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 55 Pull outward gently, but fi rmly, Figure 13.8 Opening Lower Access Panel taking care not to tear or remove the inserted tabs. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 56: Mantel And Wall Projections

    MEASUREMENT FROM FIREPLACE Figure 13.15 Minimum Vertical and Maximum Horizontal OPENING TO BOTTOM OF Dimensions of Non-Combustibles APPLIANCE= 33-1/2 IN. Figure 13.13 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 57: Facing Material

    - Top and Sides 0 in. 0 in. 0 in. High Temperature Sealant (300° F/149° C min.) Top and Side Seal Joint Figure 13.17 Noncombustible Facing Diagram Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 58: Appliance Setup

    Use this material to give the appliance a realistic ash bed. • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 59: Install The Log Assembly

    Place Log #1 on Log A. The end and bottom of Log #1 fi t into the indentation on Log A highlighted in Figure 3. The Y-shaped end of Log #1 will rest on the smooth area of Log B as shown in Figure 4. 2129-935 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 60 Place Log #1 on Log A. The end and bottom of Log #1 fi t into the indentation on Log A highlighted in Figure 9. The Y-shaped end of Log #1 will rest on the smooth area of Log B as shown in Figure 10. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 61 STEP 3. Log #3 (SRV2129-707): Place Log #3 so that it rests on the indentations located on Log #2 and Log D. Log 3 should extend beyond Log #2 by one inch. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 62: Fixed Glass Assembly

    AIR SHUTTER OPEN CLOSED LATCHES BOTH BOTTOM AND TOP) GLASS ASSEMBLY Figure 14.2 Fixed Glass Assembly Figure 14.3 Air Shutter Air Shutter Settings Burner 1/8 in. Fully open Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 63: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 64 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 65: Reference Materials

    GAS LINE ACCESS FRONT VIEW RIGHT VIEW LEFT VIEW Location Inches Millimeters Location Inches Millimeters 1-1/2 42-1/2 1080 24-1/2 33-1/2 9-1/2 2-1/8 4-1/8 34-5/8 4-1/4 Figure 16.1 GDST4336I Dimensions Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 66 GAS LINE ACCESS FRONT VIEW RIGHT VIEW LEFT VIEW Location Inches Millimeters Location Inches Millimeters 1-1/2 40-1/2 1029 24-1/2 33-1/2 9-1/2 2-1/8 34-5/8 4-1/8 4-1/4 Figure 16.2 GDFL4136I Dimensions Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 67 FRONT VIEW RIGHT VIEW LEFT VIEW Location Inches Millimeters Location Inches Millimeters 1-1/2 40-1/2 1029 24-1/2 33-1/2 9-1/2 2-1/8 24-1/2 4-1/8 34-5/8 4-1/4 Figure 16.3 GDCR4136I, GDCL4136I Dimensions Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 68: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.4 DVP Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 69 79 mm 117 mm Length 5-3/8 in. 9-3/8 in. DVP-TRAP Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.5 DVP Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 70 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.6 DVP Vent Components Cap Shield Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 71 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT FireBrickTermination Cap Figure 16.7 DVP Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 72 (233 mm) 13-5/8 IN. 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. (318 mm) SLP-LPC SLP Low Profi le Cap Figure 16.8 Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 73 8-11/16 in. 1-1/2 in. 5-1/2 in. 12 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 16.9 SLP Series Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 74 1 in. (25 mm) 13-1/2 in. 343 mm 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT SLK-SNKD Horizontal Snorkel Termination Cap Termination Cap Figure 16.10 SLP Series Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 75 14-7/16 in. 367 mm 26 in. 660 mm 2-5/16 in. 14-7/16 in. 59 mm 367 mm DVP-HSM-B SLP-WT-BK Extended Heat Shield Wall Thimble-Black Figure 16.11 SLP Series Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 76 100 FT PV Wire Harness PVI-WH100 separately. Use if the PVLP-SLP is installed in a high traffi c area. PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 16.12 PVLP-SLP Vent Components Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 77: Service Parts

    Junction Box 4021-013 Refractory Left 2129-017 Refractory Right 2129-016 Surround Overlay (contains overlay for top, bottom and sides) SRV2128-FACE Additional service part numbers appear on following page. 12/15 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 78 Non-Comb, Short Sheetrock Ledge (End) 2130-126 Surround Overlay (contains overlay for top, bottom and sides) SRV2130-FACE 2129-016 Refractory Panel Additional service part numbers appear on following page. 12/15 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 79 Junction Box Bracket Junction Box 4021-013 Non-Comb 2162-107 Refractory Bracket 2162-106 Surround Overlay (contains overlay for top, bottom and sides) SRV2132-FACE Additional service part numbers appear on following page. 12/15 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 80 2130-126 Sheetrock Ledge (End) Non-Comb 2162-107 Refractory Bracket 2162-106 Surround Overlay (contains overlay for top, bottom and sides) SRV2132-FACE Additional service part numbers appear on following page. 12/15 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 81 Flex Ball Valve Assembly 302-320A 14.9 3 Volt Transformer 593-593A 14.10 Module Wire Assembly 593-590A 14.11 Valve Bracket 2118-104 3-Hole Grommet 2118-420 Additional service part numbers appear on following page. Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 82: Service Parts

    Touch Up Paint TUP-GBK-12 Conversion Kit NG NGKS-MS36 Conversion Kit LP LPKS-MS36 Pilot Ori ce NG 2103-116 Pilot Ori ce LP 2103-117 Regulator NG 593-528 Regulator LP 593-527 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 83 Junction Box 4021-013 Refractory Left 2129-017 2129-016 Refractory Right Surround Overlay (contains overlay for top, bottom and sides) SRV2128-FACE Additional service part numbers appear on following page. 12/15 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...
  • Page 84: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2015 Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. W • 12/15...

This manual is also suitable for:

Gdst4336iGdcr4136iGdcl4136i

Table of Contents