E. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
Remove the cover plate located on the outer shell - right
side (see Figure 10.4).
Install the supplied Romex™ connector in the cover
plate.
Feed the necessary length of wire through the
connector.
Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the INSIDE of the appliance:
Remove the screw attaching the junction box/receptacle to
the outer shell, rotate the junction box inward to disengage
it from the outer shell (see Figure 10.4).
Pull the electrical wires from outside the appliance through
this opening into the valve compartment.
Feed the necessary length of wire through the
connector.
Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle to
the outer shell.
F. Wall Switch Installation for Fan
(Optional)
If the box is being wired to a wall mounted switch
for use with a fan (See Figure 10.5):
The power supply for the appliance must be
brought into a switch box.
The power can then be supplied from the
switch box to the appliance using a minimum
of 14-3 with ground wire.
At the switch box connect the black (hot) wire
and red (switch leg) wire to the wall switch as
shown.
At the appliance connect the black (hot),
white (neutral) and green (ground) wires to
the junction box as shown.
Add a 1/4 in. insulated female connector
to the red (switch leg) wire, route it through
the knockout in the face of the junction box,
and connect to the top fan switch connector
(1/4 in. male) as shown.
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Figure 10.4 Junction Box Detail
Minimum 14-3 AWG
with Ground
Junction Box
Red
Figure 10.5 Junction Box Wired to Wall Switch or BC10
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
Note: Do NOT wire 110
VAC to wall switch.
Red
Black
Black
White
White
Green
Switch Box
Knockout
Switch
Green
Power
Supply
Wires